Print

Bath fluid Thermal G

JULABO Thermal bath fluids are ideally suited for all of your temperature control applications and guarantee safe and reliable operation. Choosing the proper bath fluid is critical for best results in temperature control. Viscosity and heat transfer of Thermal fluids are specifically matched with each JULABO temperature control unit.

JULABO Thermal bath fluids have been carefully selected and are optimized for maximum performance with JULABO instruments.

Benefits

  • Low viscosity
  • High stability
  • Minimum odor
  • Good heat conductivity
  • Wide temperature ranges
  • Including drain tap

Technical Data

Order no. 5 liters 8940125
Order no. 10 liters 8940124
Working temperature (°C) -30...+80
Flash point (°C) --
Fire point (°C) --
Viscosity (kinematic at 20 °C in mm²/s) 4.07
Density (at 20 °C in g/cm³) 1.08
Pour point (°C) -70
Boiling point (°C) + 108
Ignition temperature (°C) + 430
Color light yellow
Thermal expansion coefficient K-1 0.0007
Heat conductivity [W/m*K] 0.153
Specific volume resistivity [Ohm*cm] 200

This accessory is suited for:
CORIO CD, CORIO CD-200F, CORIO CD-201F, CORIO CD-300F, CORIO CD-600F, CORIO CD-B13, CORIO CD-B17, CORIO CD-B19, CORIO CD-B27, CORIO CD-B33, CORIO CD-B39, CORIO CD-B5, CORIO CD-BC12, CORIO CD-BC26, CORIO CD-BC4, CORIO CD-BC6, DYNEO DD, DYNEO DD-1000F, DYNEO DD-1001F, DYNEO DD-200F, DYNEO DD-201F, DYNEO DD-300F, DYNEO DD-600F, DYNEO DD-601F, DYNEO DD-900F, DYNEO DD-BC12, DYNEO DD-BC26, DYNEO DD-BC4, DYNEO DD-BC6, F1000, F12-MA, F25-HE, F25-HL, F25-MA, F250, F32-HE, F32-HL, F32-MA, F33-HL, F33-MA, F34-HE, F34-MA, F500, F70-ME, F81-ME, F95-SL, FC1200, FC1200S, FC1200T, FC1600, FC1600S, FC1600T, FC600, FC600S, FCW2500T, FCW600, FCW600S, FK30-SL, FK31-SL, FL11006, FL1201, FL1203, FL1701, FL1703, FL20006, FL2503, FL2506, FL300, FL4003, FL4006, FL601, FL7006, FLW20006, FP35-HL, FP35-MA, FP40-HE, FP40-HL, FP40-MA, FP50-HE, FP50-HL, FP50-MA, FP51-SL, FP52-SL, FP52-SL, FP52-SL-150C, FP55-SL, FP55-SL-150C, FP89-HL, FP89-ME, FP90-SL, FP90-SL-150C, FPW50-HE, FPW50-HL, FPW50-MA, FPW50-ME, FPW52-SL, FPW52-SL-150C, FPW55-SL, FPW55-SL-150C, FPW90-SL-150C, FPW91-SL, FW95-SL, HE-4, HL-4, MA, MA-12, MA-26, MA-6, ME-16G, ME-18V, SC10000w SemiChill, SC2500a SemiChill, SC2500w SemiChill, SC5000a SemiChill, SC5000w SemiChill, SE-12, SE-26, SE-6, SL-12, SL-14K, SL-26, SL-6, SL-8K

Technical changes without prior notification.
Images may deviate from the original.

Contact

JULABO GmbH
Gerhard-Juchheim-Strasse 1
77960 Seelbach / Germany
Tel: +49 7823 51-0
info.de@julabo.com
www.julabo.com
Contact form

Catalog request
Order our brochures!