FL601 Recirculating Coolers for installation below a lab bench

compact models with up to 1.7 kW of cooling capacity for installation below a lab bench

The compact FL models are suited for a wide variety of cooling tasks. Installation under a lab bench saves valuable space. 2 variants: Air-cooled (FL) and water-cooled (FLW).

Request a quote
Data at mains voltage / frequency:
230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F)
FL601
Order No. 9 661 006
Working temperature range -20 ... +40 °C
Temperature stability ±0.5 °C
Cooling capacity
°C
kW
20 10 0 -10 -20
0.6 0.5 0.4 0.33 0.2
Cooling capacity
(Medium: Ethanol)
°C 20 10 0 -10 -20
kW 0.6 0.5 0.4 0.33 0.2
Pump capacity flow rate 23 l/min
Pump capacity flow pressure 1 bar
Filling volume 5.5 ... 8 l
Dimensions
(W × L × H)
32 x 50 x 62 cm
FL601
Order No. 9 661 006
Working temperature range -20 ... +40 °C
Temperature stability ±0.5 °C
Cooling capacity
(Medium: Water Glycol)
°C
kW
20 10 0 -10 -20
0.6 0.5 0.4 0.32 0.1
Cooling capacity
(Medium: Ethanol)
°C 20 10 0 -10 -20
kW 0.6 0.5 0.4 0.32 0.1
Pump capacity flow rate 23 l/min
Pump capacity flow pressure 1 bar
Filling volume 5.5 ... 8 l
Dimensions
(W × L × H)
32 x 50 x 62 cm
FL601
Order No. 9 661 006
Working temperature range -20 ... +40 °C
Temperature stability ±0.5 °C
Cooling capacity
(Medium: Water Glycol)
°C
kW
20 10 0 -10 -20
0.6 0.5 0.4 0.33 0.2
Cooling capacity
(Medium: Ethanol)
°C 20 10 0 -10 -20
kW 0.6 0.5 0.4 0.33 0.2
Pump capacity flow rate 23 l/min
Pump capacity flow pressure 1 bar
Filling volume 5.5 ... 8 l
Dimensions
(W × L × H)
32 x 50 x 62 cm
FL601
Order No. 9 661 006
Working temperature range -20 ... +40 °C
Temperature stability ±0.5 °C
Cooling capacity
°C
kW
20 10 0 -10 -20
0.6 0.5 0.4 0.33 0.2
Cooling capacity
(Medium: Ethanol)
°C 20 10 0 -10 -20
kW 0.6 0.5 0.4 0.33 0.2
Pump capacity flow rate 23 l/min
Pump capacity flow pressure 1 bar
Filling volume 5.5 ... 8 l
Dimensions
(W × L × H)
32 x 50 x 62 cm
FL601
Order No. 9 661 006
Working temperature range -20 ... +40 °C
Temperature stability ±0.5 °C
Cooling capacity
(Medium: Water Glycol)
°C
kW
20 10 0 -10 -20
0.6 0.5 0.4 0.33 0.2
Cooling capacity
(Medium: Ethanol)
°C 20 10 0 -10 -20
kW 0.6 0.5 0.4 0.33 0.2
Pump capacity flow rate 23 l/min
Pump capacity flow pressure 1 bar
Filling volume 5.5 ... 8 l
Dimensions
(W × L × H)
32 x 50 x 62 cm

Product Features

  • Ergonomic design and easy operation
  • Splash-proof keypad
  • Large, bright LED display
  • Reliable Microprocessor PID temperature control
  • Powerful immersion pumps, suitable for continuous operation
  • Permissible temperature in return line +80°C
  • Easy filling and Drain tap easily accessible
  • Low liquid level protection with optical and audible alarm signal
  • Integrated stainless steel bath tanks
  • Front drain
  • No side vents, instruments can be placed right next to other equipment
  • RS232 interface for PC connection
  • IP class according to IEC 60529: 21
  • Alarm output, potential-free change-over contact (max. 30 VA)
Dimensions and volumes
Dimensions
(W × L × H)
32 x 50 x 62 cm
Filling volume 5.5 ... 8 l
Weight 48 kg
Pump connections M16x1 male
Barbed fittings inner diameter 8/12 mm
Temperature values
Working temperature range -20 ... +40 °C
Temperature stability ±0.5 °C
Setting the resolution of the temperature display 0.1 °C
Temperature display resolution 0.1 °C
Ambient temperature 5 ... 40 °C
Return flow temperature max. 80 °C
Data at mains voltage / frequency:
230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F)
Performance values
Cooling capacity
°C
kW
20 10 0 -10 -20
0.6 0.5 0.4 0.33 0.2
Cooling capacity
(Medium: Ethanol)
°C 20 10 0 -10 -20
kW 0.6 0.5 0.4 0.33 0.2
Pump capacity flow rate 23 l/min
Pump capacity flow pressure 1 bar
Refrigerant stage 1
Refrigerant R449A
Global Warming Potential for R449A 1397
Filling volume 240 g
Carbon dioxide equivalent 0.335 t
Power 5 A
Performance values
Cooling capacity
(Medium: Water Glycol)
°C
kW
20 10 0 -10 -20
0.6 0.5 0.4 0.32 0.1
Cooling capacity
(Medium: Ethanol)
°C 20 10 0 -10 -20
kW 0.6 0.5 0.4 0.32 0.1
Pump capacity flow rate 23 l/min
Pump capacity flow pressure 1 bar
Refrigerant stage 1
Refrigerant R449A
Global Warming Potential for R449A 1397
Filling volume 260 g
Carbon dioxide equivalent 0.363 t
Power 10 A
Performance values
Cooling capacity
(Medium: Water Glycol)
°C
kW
20 10 0 -10 -20
0.6 0.5 0.4 0.33 0.2
Cooling capacity
(Medium: Ethanol)
°C 20 10 0 -10 -20
kW 0.6 0.5 0.4 0.33 0.2
Pump capacity flow rate 23 l/min
Pump capacity flow pressure 1 bar
Refrigerant stage 1
Refrigerant R452A
Global Warming Potential for R452A 2140
Filling volume 325 g
Carbon dioxide equivalent 0.696 t
Power 5 A
Performance values
Cooling capacity
°C
kW
20 10 0 -10 -20
0.6 0.5 0.4 0.33 0.2
Cooling capacity
(Medium: Ethanol)
°C 20 10 0 -10 -20
kW 0.6 0.5 0.4 0.33 0.2
Pump capacity flow rate 23 l/min
Pump capacity flow pressure 1 bar
Refrigerant stage 1
Refrigerant R452A
Global Warming Potential for R452A 2140
Filling volume 325 g
Carbon dioxide equivalent 0.696 t
Power 5 A
Performance values
Cooling capacity
(Medium: Water Glycol)
°C
kW
20 10 0 -10 -20
0.6 0.5 0.4 0.33 0.2
Cooling capacity
(Medium: Ethanol)
°C 20 10 0 -10 -20
kW 0.6 0.5 0.4 0.33 0.2
Pump capacity flow rate 23 l/min
Pump capacity flow pressure 1 bar
Refrigerant stage 1
Refrigerant R452A
Global Warming Potential for R452A 2140
Filling volume 325 g
Carbon dioxide equivalent 0.696 t
Power 5 A
Bath
Bath tank Stainless steel
Cooling
Cooling of compressor 1-stage Air
Other
Sound pressure level 55 dbA
Classification
according to DIN12876-1
Classification I (NFL)
IP Code
according to IEC 60529
IP 21
Pump type Centrifugal Pump
Electronics
Temperature control PID1
Temperature display LED
Temperature setting Keypad
Available voltage versions
230V/60Hz Nema N6-20 Plug 9661006.13
115V/60Hz Nema N5-15 Plug 9661006.02
230V/50Hz Schuko Plug - CEE 7/4 Plug Type F 9661006.03
230V/50Hz UK Plug Type BS1363A 9661006.04
230V/50Hz CH Plug Type SEV 1011 9661006.05
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)

Pump capacity

Accessory for FL601

We would also be happy to send you our printed catalogs and brochures by post.


Request brochure

Benefits

  • 100% geprüft
    100% Checked.
    100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
  • Blatt wächst in einer Glühbirne
    Green technology.
    Development consistently applied environmentally friendly materials and technologies.
  • Made in Germany
    JULABO. Quality.
    Highest standards of quality for a long product life.
  • Quickstart
    Quick start.
    Individual JULABO consultation and comprehensive manuals at your disposal.