CORIO CD-B5 Heating Circulator with Stainless Steel Open Bath
for internal and external applications at workingtemperatures up to +150 °C
The Open Heating Bath Circulators of the new CORIO series feature high-quality bath tanks made of stainless steel.
Request a quote
| Order No. | 9 012 405.01 | |
|---|---|---|
| Working temperature range | +20 ... +150 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 0.8 kW | |
| Pump capacity flow rate | 15 l/min | |
| Pump capacity flow pressure | 0.27 bar | |
|
Usable bath opening (W x L / D) |
15 x 15 / 15 cm | |
| Filling volume | 3.5 ... 5 l | |
|
Dimensions (W × L × H) |
23 x 38 x 41 cm | |
| Order No. | 9 012 405.01 | |
|---|---|---|
| Working temperature range | +20 ... +150 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 0.8 kW | |
| Pump capacity flow rate | 15 l/min | |
| Pump capacity flow pressure | 0.27 bar | |
|
Usable bath opening (W x L / D) |
15 x 15 / 15 cm | |
| Filling volume | 3.5 ... 5 l | |
|
Dimensions (W × L × H) |
23 x 38 x 41 cm | |
| Order No. | 9 012 405.02 | |
|---|---|---|
| Working temperature range | +20 ... +150 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 1 kW | |
| Pump capacity flow rate | 16 l/min | |
| Pump capacity flow pressure | 0.33 bar | |
|
Usable bath opening (W x L / D) |
15 x 15 / 15 cm | |
| Filling volume | 3.5 ... 5 l | |
|
Dimensions (W × L × H) |
23 x 38 x 41 cm | |
| Order No. | 9 012 405.03 | |
|---|---|---|
| Working temperature range | +20 ... +150 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 2 kW | |
| Pump capacity flow rate | 15 l/min | |
| Pump capacity flow pressure | 0.35 bar | |
|
Usable bath opening (W x L / D) |
15 x 15 / 15 cm | |
| Filling volume | 3.5 ... 5 l | |
|
Dimensions (W × L × H) |
23 x 38 x 41 cm | |
| Order No. | 9 012 405.03.chn | |
|---|---|---|
| Working temperature range | +20 ... +150 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 2 kW | |
| Pump capacity flow rate | 15 l/min | |
| Pump capacity flow pressure | 0.35 bar | |
|
Usable bath opening (W x L / D) |
15 x 15 / 15 cm | |
| Filling volume | 3.5 ... 5 l | |
|
Dimensions (W × L × H) |
23 x 38 x 41 cm | |
| Order No. | 9 012 405.04 | |
|---|---|---|
| Working temperature range | +20 ... +150 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 2 kW | |
| Pump capacity flow rate | 15 l/min | |
| Pump capacity flow pressure | 0.35 bar | |
|
Usable bath opening (W x L / D) |
15 x 15 / 15 cm | |
| Filling volume | 3.5 ... 5 l | |
|
Dimensions (W × L × H) |
23 x 38 x 41 cm | |
| Order No. | 9 012 405.05 | |
|---|---|---|
| Working temperature range | +20 ... +150 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 2 kW | |
| Pump capacity flow rate | 15 l/min | |
| Pump capacity flow pressure | 0.35 bar | |
|
Usable bath opening (W x L / D) |
15 x 15 / 15 cm | |
| Filling volume | 3.5 ... 5 l | |
|
Dimensions (W × L × H) |
23 x 38 x 41 cm | |
| Order No. | 9 012 405.13 | |
|---|---|---|
| Working temperature range | +20 ... +150 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 2 kW | |
| Pump capacity flow rate | 17 l/min | |
| Pump capacity flow pressure | 0.43 bar | |
|
Usable bath opening (W x L / D) |
15 x 15 / 15 cm | |
| Filling volume | 3.5 ... 5 l | |
|
Dimensions (W × L × H) |
23 x 38 x 41 cm | |
Product Features
- Models for internal applications
- Bright, white, easy to read display
- Very quiet
- USB connection
- High-quality bath tanks made of stainless steel
- Integrated drain screw (except B5)
|
Dimensions (W × L × H) |
23 x 38 x 41 cm |
|---|---|
| Filling volume | 3.5 ... 5 l |
| Weight | 8.2 kg |
| Pump connections | M16x1 male |
| Barbed fittings inner diameter | 8/12 mm |
| Working temperature range | +20 ... +150 °C |
|---|---|
| Temperature stability | ±0.03 °C |
| Setting the resolution of the temperature display | 0.1 °C |
| Temperature display resolution | 0.01 ... 0.1 °C |
| Ambient temperature | +5 ... +40 °C |
| Heating capacity | 0.8 kW |
|---|---|
| Pump capacity flow rate | 15 l/min |
| Pump capacity flow pressure | 0.27 bar |
| Viscosity max. | 50 cST |
| Heating capacity | 0.8 kW |
|---|---|
| Pump capacity flow rate | 15 l/min |
| Pump capacity flow pressure | 0.27 bar |
| Viscosity max. | 50 cST |
| Heating capacity | 1 kW |
|---|---|
| Pump capacity flow rate | 16 l/min |
| Pump capacity flow pressure | 0.33 bar |
| Viscosity max. | 50 cST |
| Heating capacity | 2 kW |
|---|---|
| Pump capacity flow rate | 15 l/min |
| Pump capacity flow pressure | 0.35 bar |
| Viscosity max. | 50 cST |
| Heating capacity | 2 kW |
|---|---|
| Pump capacity flow rate | 15 l/min |
| Pump capacity flow pressure | 0.35 bar |
| Viscosity max. | 50 cST |
| Heating capacity | 2 kW |
|---|---|
| Pump capacity flow rate | 15 l/min |
| Pump capacity flow pressure | 0.35 bar |
| Viscosity max. | 50 cST |
| Heating capacity | 2 kW |
|---|---|
| Pump capacity flow rate | 15 l/min |
| Pump capacity flow pressure | 0.35 bar |
| Viscosity max. | 50 cST |
| Heating capacity | 2 kW |
|---|---|
| Pump capacity flow rate | 17 l/min |
| Pump capacity flow pressure | 0.43 bar |
| Viscosity max. | 50 cST |
| Bath tank | Stainless steel |
|---|---|
| Bath cover | accessory |
|
Usable bath opening (W x L / D) |
15 x 15 / 15 cm |
| Cooling coil | accessory |
|---|
| Classification according to DIN12876-1 |
Classification III (FL) |
|---|---|
| IP Code according to IEC 60529 |
IP 21 |
| Pump function | Pressure Pump |
| Pump type | Immersion Pump |
| Temperature control | PID1 |
|---|---|
| Absolute temperature calibration | 1 Point Calibration |
| Temperature display | LED |
| Temperature setting | Keypad |
| 100V/50-60Hz Nema N5-15 Plug | 9012405.01 |
|---|---|
| 115V/60Hz Nema N5-15 Plug | 9012405.02 |
| 230V/50Hz Schuko Plug - CEE 7/4 Plug Type F | 9012405.03 |
| 230V/50Hz CN Plug | 9012405.03.chn |
| 230V/50Hz UK Plug Type BS1363A | 9012405.04 |
| 230V/50Hz CH Plug Type SEV 1011 | 9012405.05 |
| 230V/60Hz Schuko Plug - CEE 7/4 Plug Type F | 9012405.13 |
| 2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Overview
- Dimensions and volumes
- Power and capacities
- Bath
- Cooling
- Other
- Electronics
- Available voltage versions
Accessory for CORIO CD-B5
Benefits
-
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory. -
ATC.
Absolute Temperature Calibration, 1-point calibration (CD). -
Green technology.
Development consistently applied environmentally friendly materials and technologies. -
Internal. External.
The pump is controlled via a lever located directly below the display. Easily change between internal and external circulation.
-
JULABO. Quality.
Highest standards of quality for a long product life. -
Modern. Reliable.
High-grade components in every JULABO Circulator – platinum sensors, proven motor technology, CAN-Bus communication and much more. -
Satisfied customers.
11 subsidiaries and more than 100 partners worldwide guarantee fast and qualified JULABO support. -
Services 24/7.
Around the clock availability. You can find suitable accessories, data sheets, manuals, case studies, and more at www.julabo.com. -
Stable.
Rubber feet allow for a secured footing of your CORIO to prevent damage to your laboratory equipment. -
Quick start.
Individual JULABO consultation and comprehensive manuals at your disposal. -
Timer. Integrated.
CORIO circulators include an integrated timer function. When the set time has elapsed, a signal sounds and the device switches off. Setting range: 0 ... 999 minutes. -
Brilliant.
Very bright display makes it easy to read even from a distance. -
Connection. Easy.
Inclined pump connections (M16×1) facilitate the connection of applications. Each unit includes 2 barbed fittings of 8/12 mm diameter each. -
Everything at the front.
All operating controls and safety functions are accessed easily and comfortably from the front. -
Exact.
You can rely on it. PID1 control and 'Active Cooling Control' make the new CORIO precise and perfect. -
Locked in.
The lockable power plug guarantees safe connection. More process safety. -
Switch on. And off you go.
Intelligent operating concept. Ready for operation with just a few quick and easy steps. -
Early warning system for low liquid level
Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down -
Connectivity.
Remote control made easy. CORIO CD circulators feature a USB connection.