FL20006 Powerful recirculating cooler

Models with particularly high power reserves

The powerful FL models are suitable for a wide range of cooling tasks in industrial environments, such as removal of large process heat. 2 variants: Air-cooled (FL) and water-cooled (FLW).

Request a quote
Data at mains voltage / frequency:
400V/3PNPE/50Hz (Plug 32A CEE)
FL20006
Order No. 9 666 200.16
Working temperature range -25 ... +40 °C
Temperature stability ±0.5 °C
Cooling capacity
(Medium: Water Glycol)
°C
kW
20 10 0 -10 -20
20 15 10 6 1.1
Cooling capacity
(Medium: Ethanol)
°C 20 10 0 -10 -20
kW 20 15 10 6 1.1
Pump capacity flow rate 80 l/min
Pump capacity flow pressure 0.8 ... 6 bar
Filling volume 15 ... 37 l
Dimensions
(W × L × H)
95 x 115 x 161 cm
FL20006
Order No. 9 666 200.07
Working temperature range -25 ... +40 °C
Temperature stability ±0.5 °C
Cooling capacity
(Medium: Water Glycol)
°C
kW
20 10 0 -10 -20
20 15 10 6 2.5
Cooling capacity
(Medium: Ethanol)
°C 20 10 0 -10 -20
kW 20 15 10 6 2.5
Pump capacity flow rate 80 l/min
Pump capacity flow pressure 0.8 ... 6 bar
Filling volume 15 ... 37 l
Dimensions
(W × L × H)
95 x 115 x 161 cm

Product Features

  • Ergonomic design and easy operation
  • Splash-proof keypad
  • Large, bright LED display
  • Permissible temperature in return line +80°C
  • Easy filling from the top with hinged protective lid
  • Low liquid level protection with optical and audible alarm signal
  • Integrated stainless steel bath tanks
  • Removable ventilation grid
  • Front drain
  • No side vents, instruments can be placed right next to other equipment
  • RS232 interface for PC connection
  • IP class according to IEC 60529: 21
  • Alarm output, potential-free change-over contact (max. 30 VA)
  • Pressure Indicator
  • By-pass valve to adjust pump pressure
Dimensions and volumes
Dimensions
(W × L × H)
95 x 115 x 161 cm
Filling volume 15 ... 37 l
Weight 375 kg
Pump connections G1¼"  male
Barbed fittings inner diameter 1"
Temperature values
Working temperature range -25 ... +40 °C
Temperature stability ±0.5 °C
Setting the resolution of the temperature display 0.1 °C
Temperature display resolution 0.1 °C
Ambient temperature 5 ... 40 °C
Return flow temperature max. 80 °C
Data at mains voltage / frequency:
400V/3PNPE/50Hz (Plug 32A CEE)
Performance values
Cooling capacity
(Medium: Water Glycol)
°C
kW
20 10 0 -10 -20
20 15 10 6 1.1
Cooling capacity
(Medium: Ethanol)
°C 20 10 0 -10 -20
kW 20 15 10 6 1.1
Pump capacity flow rate 80 l/min
Pump capacity flow pressure 0.8 ... 6 bar
Refrigerant stage 1
Refrigerant R449A
Global Warming Potential for R449A 1397
Filling volume 5500 g
Carbon dioxide equivalent 7.684 t
Performance values
Cooling capacity
(Medium: Water Glycol)
°C
kW
20 10 0 -10 -20
20 15 10 6 2.5
Cooling capacity
(Medium: Ethanol)
°C 20 10 0 -10 -20
kW 20 15 10 6 2.5
Pump capacity flow rate 80 l/min
Pump capacity flow pressure 0.8 ... 6 bar
Refrigerant stage 1
Refrigerant R452A
Global Warming Potential for R452A 2140
Filling volume 5950 g
Carbon dioxide equivalent 12.733 t
Bath
Bath tank Stainless steel
Cooling
Cooling of compressor 1-stage Air
Other
Sound pressure level 73 dbA
Classification
according to DIN12876-1
Classification I (NFL)
IP Code
according to IEC 60529
IP 21
Pump type Centrifugal Pump
Electronics
Temperature control PID1
Temperature display LED
Temperature setting Keypad
Available voltage versions
230V/3PPE/60Hz Without Plug 9666200.16
400V/3PNPE/50Hz Plug 32A CEE 9666200.07
Included in delivery
2 each barbed fittings for tubing 1" inner dia (pumpconnections G1 1/4" male)

Pump capacity

chart_pp-FL20006

Accessory for FL20006

We would also be happy to send you our printed catalogs and brochures by post.


Request brochure

Benefits

  • 100% geprüft
    100% Checked.
    100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
  • Blatt wächst in einer Glühbirne
    Green technology.
    Development consistently applied environmentally friendly materials and technologies.
  • Made in Germany
    JULABO. Quality.
    Highest standards of quality for a long product life.
  • Quickstart
    Quick start.
    Individual JULABO consultation and comprehensive manuals at your disposal.