FL Recirculating Coolers
Chill Environmentally Friendly and Economical
The FL series offers a new generation of chillers for routine cooling applications within the laboratory and industry. The temperature stability of the PID control is ±0.5°C.
All units can easily be cleaned and are provided with a splash water proof keypad with LED temperature indication. On the front of the units there is an RS232 interface as well as an alarm shutdown. The filling port is easily accessible placed on the top under a lift-up cover. Another hinged tray serves as a file for the operating manual or other documents concerning the installation. The removable venting grid allows an easy cleaning of the condenser, the drain tap is easily accessible behind the grid. All models include an easily visible level indication. Another advantage is the venting slots are on the front and rear and therefore the units can be placed directly one beside the other (space saving).
Product Features
- Splash-proof keypad
- Large, bright LED display
- Reliable Microprocessor PID temperature control
- Powerful immersion pumps, suitable for continuous operation
- Easy filling and Drain tap easily accessible
- Low liquid level protection with optical and audible alarm signal
- Front drain
- No side vents, instruments can be placed right next to other equipment
- RS232 interface for PC connection
- Easy filling from the top with hinged protective lid
- Ergonomic design and easy operation
- Pressure Indicator
Product Overview
FL Recirculating cooler up to 1.7 KW cooling capacity
compact models with up to 1.7 kW of cooling capacity for installation below a lab bench
The compact FL models are suited for a wide variety of cooling tasks. Installation under a lab bench saves valuable space. 2 variants: Air-cooled (FL) and water-cooled (FLW).
| Model | Add to compare FL601 |
Add to compare FL1201 |
Add to compare FL1203 |
Add to compare FL1701 |
|---|---|---|---|---|
| Working temperature range (°C) | -20 ... 40 | -20 ... 40 | -20 ... 40 | -20 ... 40 |
| Temperature stability (°C) | ±0.5 | ±0.5 | ±0.5 | ±0.5 |
| Cooling capacity (kW) | 0.6 | 1.2 | 1.2 | 1.7 |
| Pump capacity flow rate (l/min) | 23 | 23 | 40 | 23 |
| Pump capacity pressure (bar) | 1 | 1 | 0.5 ... 3 | 1 |
| Model | Add to compare FL1703 |
Add to compare FLW1701 |
Add to compare FLW1703 |
|---|---|---|---|
| Working temperature range (°C) | -20 ... 40 | -20 ... 40 | -20 ... 40 |
| Temperature stability (°C) | ±0.5 | ±0.5 | ±0.5 |
| Cooling capacity (kW) | 1.7 | 1.7 | 1.7 |
| Pump capacity flow rate (l/min) | 40 | 23 | 40 |
| Pump capacity pressure (bar) | 0.5 ... 3 | 1 | 0.5 ... 3 |
FL Recirculating cooler with up to 4.3 kW of cooling capacity
The FL models shown here have higher cooling capacity, powerful circulating pumps, and internal bath volumes of up to 30 liters. 2 variants: Air-cooled (FL) and water-cooled (FLW).
| Model | Add to compare FL2503 |
Add to compare FL2506 |
Add to compare FLW2506 |
Add to compare FLW2503 |
|---|---|---|---|---|
| Working temperature range (°C) | -20 ... 40 | -15 ... 40 | -15 ... 40 | -20 ... 40 |
| Temperature stability (°C) | ±0.5 | ±0.5 | ±0.5 | ±0.5 |
| Cooling capacity (kW) | 2.5 | 2.5 | 2.5 | 2.7 |
| Pump capacity flow rate (l/min) | 40 | 60 | 60 | 40 |
| Pump capacity pressure (bar) | 0.5 ... 3 | 0.5 ... 6 | 0.5 ... 6 | 0.5 ... 3 |
| Model | Add to compare FL4003 |
Add to compare FLW4003 |
Add to compare FL4006 |
Add to compare FLW4006 |
|---|---|---|---|---|
| Working temperature range (°C) | -20 ... 40 | -20 ... 40 | -20 ... 40 | -15 ... 40 |
| Temperature stability (°C) | ±0.5 | ±0.5 | ±0.5 | ±0.5 |
| Cooling capacity (kW) | 4 | 4.3 | 4 | 4 |
| Pump capacity flow rate (l/min) | 40 | 40 | 60 | 60 |
| Pump capacity pressure (bar) | 0.5 ... 3 | 0.5 ... 3 | 0.5 ... 6 | 0.5 ... 6 |
FL Recirculating cooler with up to 20 kW of cooling capacity
Models with particularly high power reserves
The powerful FL models are suitable for a wide range of cooling tasks in industrial environments, such as removal of large process heat. 2 variants: Air-cooled (FL) and water-cooled (FLW).
| Model | Add to compare FL7006 |
Add to compare FLW7006 |
Add to compare FL11006 |
Add to compare FLW11006 |
|---|---|---|---|---|
| Working temperature range (°C) | -20 ... 40 | -20 ... 40 | -20 ... 40 | -20 ... 40 |
| Temperature stability (°C) | ±0.5 | ±0.5 | ±0.5 | ±0.5 |
| Cooling capacity (kW) | 7 | 7.4 | 11 | 11.5 |
| Pump capacity flow rate (l/min) | 60 | 60 | 60 | 60 |
| Pump capacity pressure (bar) | 0.5 ... 6 | 0.5 ... 6 | 0.5 ... 6 | 0.5 ... 6 |