CORIO CD-B13 Heating Circulator with Stainless Steel Open Bath

for internal and external applications at workingtemperatures up to +150 °C

The Open Heating Bath Circulators of the new CORIO series feature high-quality bath tanks made of stainless steel.

Request a quote
Data based on voltage version:
230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F)
CD-B13
Order No. 9 012 413.01
Working temperature range +20 ... +150 °C
Temperature stability ±0.03 °C
Heating capacity 0.8 kW
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.27 bar
Usable bath opening
(W x L / D)
30 x 18 / 15 cm
Filling volume 9 ... 13 l
Dimensions
(W × L × H)
38 x 40 x 42 cm
CD-B13
Order No. 9 012 413.01
Working temperature range +20 ... +150 °C
Temperature stability ±0.03 °C
Heating capacity 0.8 kW
Pump capacity flow rate 16 l/min
Pump capacity flow pressure 0.35 bar
Usable bath opening
(W x L / D)
30 x 18 / 15 cm
Filling volume 9 ... 13 l
Dimensions
(W × L × H)
38 x 40 x 42 cm
CD-B13
Order No. 9 012 413.02
Working temperature range +20 ... +150 °C
Temperature stability ±0.03 °C
Heating capacity 1 kW
Pump capacity flow rate 16 l/min
Pump capacity flow pressure 0.33 bar
Usable bath opening
(W x L / D)
30 x 18 / 15 cm
Filling volume 9 ... 13 l
Dimensions
(W × L × H)
38 x 40 x 42 cm
CD-B13
Order No. 9 012 413.03
Working temperature range +20 ... +150 °C
Temperature stability ±0.03 °C
Heating capacity 2 kW
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.35 bar
Usable bath opening
(W x L / D)
30 x 18 / 15 cm
Filling volume 9 ... 13 l
Dimensions
(W × L × H)
38 x 40 x 42 cm
CD-B13
Order No. 9 012 413.03.chn
Working temperature range +20 ... +150 °C
Temperature stability ±0.03 °C
Heating capacity 2 kW
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.35 bar
Usable bath opening
(W x L / D)
30 x 18 / 15 cm
Filling volume 9 ... 13 l
Dimensions
(W × L × H)
38 x 40 x 42 cm
CD-B13
Order No. 9 012 413.04
Working temperature range +20 ... +150 °C
Temperature stability ±0.03 °C
Heating capacity 2 kW
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.35 bar
Usable bath opening
(W x L / D)
30 x 18 / 15 cm
Filling volume 9 ... 13 l
Dimensions
(W × L × H)
38 x 40 x 42 cm
CD-B13
Order No. 9 012 413.05
Working temperature range +20 ... +150 °C
Temperature stability ±0.03 °C
Heating capacity 2 kW
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.35 bar
Usable bath opening
(W x L / D)
30 x 18 / 15 cm
Filling volume 9 ... 13 l
Dimensions
(W × L × H)
38 x 40 x 42 cm
CD-B13
Order No. 9 012 413.13
Working temperature range +20 ... +150 °C
Temperature stability ±0.03 °C
Heating capacity 2 kW
Pump capacity flow rate 17 l/min
Pump capacity flow pressure 0.43 bar
Usable bath opening
(W x L / D)
30 x 18 / 15 cm
Filling volume 9 ... 13 l
Dimensions
(W × L × H)
38 x 40 x 42 cm

Product Features

  • Integrated drain screw
  • Models for internal applications
  • Bright, white, easy to read display
  • Very quiet
  • USB connection
  • High-quality bath tanks made of stainless steel
  • Integrated drain screw (except B5)
Dimensions and volumes
Dimensions
(W × L × H)
38 x 40 x 42 cm
Filling volume 9 ... 13 l
Weight 9.1 kg
Pump connections M16x1  male
Barbed fittings inner diameter 8/12 mm
Temperature values
Working temperature range +20 ... +150 °C
Temperature stability ±0.03 °C
Setting the resolution of the temperature display 0.1 °C
Temperature display resolution 0.01 ... 0.1 °C
Ambient temperature +5 ... +40 °C
Data based on voltage version:
230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F)
Performance values
Heating capacity 0.8 kW
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.27 bar
Viscosity max. 50 cST
Performance values
Heating capacity 0.8 kW
Pump capacity flow rate 16 l/min
Pump capacity flow pressure 0.35 bar
Viscosity max. 50 cST
Performance values
Heating capacity 1 kW
Pump capacity flow rate 16 l/min
Pump capacity flow pressure 0.33 bar
Viscosity max. 50 cST
Performance values
Heating capacity 2 kW
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.35 bar
Viscosity max. 50 cST
Performance values
Heating capacity 2 kW
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.35 bar
Viscosity max. 50 cST
Performance values
Heating capacity 2 kW
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.35 bar
Viscosity max. 50 cST
Performance values
Heating capacity 2 kW
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.35 bar
Viscosity max. 50 cST
Performance values
Heating capacity 2 kW
Pump capacity flow rate 17 l/min
Pump capacity flow pressure 0.43 bar
Viscosity max. 50 cST
Bath
Bath tank Stainless steel
Bath cover accessory
Usable bath opening
(W x L / D)
30 x 18 / 15 cm
Cooling
Cooling coil accessory
Other
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Pump function Pressure Pump
Pump type Immersion Pump
Electronics
Temperature control PID1
Absolute temperature calibration 1 Point Calibration
Temperature display LED
Temperature setting Keypad
Available voltage versions
100V/50-60Hz Nema N5-15 Plug 9012413.01
115V/60Hz Nema N5-15 Plug 9012413.02
230V/50Hz Schuko Plug - CEE 7/4 Plug Type F 9012413.03
230V/50Hz CN Plug 9012413.03.chn
230V/50Hz UK Plug Type BS1363A 9012413.04
230V/50Hz CH Plug Type SEV 1011 9012413.05
230V/60Hz Schuko Plug - CEE 7/4 Plug Type F 9012413.13
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)

Accessory for CORIO CD-B13

Brochure

CORIO Brochure
English
PDF - 6.77 MB

Download

Operation Manual

19510800-V9
English
PDF - 6.44 MB

Download

Product Data Sheet

CORIO CD-B13
English
PDF - 340.86 KB

Download

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

Benefits

  • 100% geprüft
    100% Checked.
    100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
  • ATC.ai
    ATC.
    Absolute Temperature Calibration, 1-point calibration (CD).
  • Blatt wächst in einer Glühbirne
    Green technology.
    Development consistently applied environmentally friendly materials and technologies.
  • easy-pump-control.psd
    Internal. External.
    The pump is controlled via a lever located directly below the display. Easily change between internal and external circulation.
  • Made in Germany
    JULABO. Quality.
    Highest standards of quality for a long product life.
  •  -- en
    Modern. Reliable.
    High-grade components in every JULABO Circulator – platinum sensors, proven motor technology, CAN-Bus communication and much more.
  • network
    Satisfied customers.
    11 subsidiaries and more than 100 partners worldwide guarantee fast and qualified JULABO support.
  • Downloads
    Services 24/7.
    Around the clock availability. You can find suitable accessories, data sheets, manuals, case studies, and more at www.julabo.com.
  •  -- en
    Stable.
    Rubber feet allow for a secured footing of your CORIO to prevent damage to your laboratory equipment.
  • Quickstart
    Quick start.
    Individual JULABO consultation and comprehensive manuals at your disposal.
  • timer-function.psd
    Timer. Integrated.
    CORIO circulators include an integrated timer function. When the set time has elapsed, a signal sounds and the device switches off. Setting range: 0 ... 999 minutes.
  • brilliant-display.psd
    Brilliant.
    Very bright display makes it easy to read even from a distance.
  • easy-conectivity.psd
    Connection. Easy.
    Inclined pump connections (M16×1) facilitate the connection of applications. Each unit includes 2 barbed fittings of 8/12 mm diameter each.
  • all-in-front.psd
    Everything at the front.
    All operating controls and safety functions are accessed easily and comfortably from the front.
  • ACCUND_PID1.ai
    Exact.
    You can rely on it. PID1 control and 'Active Cooling Control' make the new CORIO precise and perfect.
  • profesional-plug-connection.psd
    Locked in.
    The lockable power plug guarantees safe connection. More process safety.
  • switch-on-start.psd
    Switch on. And off you go.
    Intelligent operating concept. Ready for operation with just a few quick and easy steps.
  • EarlyWarningSystemLowLiquid.ai
    Early warning system for low liquid level
    Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down
  • usb-connectivity.psd
    Connectivity.
    Remote control made easy. CORIO CD circulators feature a USB connection.