FL11006 Powerful recirculating cooler
Models with particularly high power reserves
The powerful FL models are suitable for a wide range of cooling tasks in industrial environments, such as removal of large process heat. 2 variants: Air-cooled (FL) and water-cooled (FLW).
Request a quoteOrder No. | 9 666 110.16 | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -20 ... +40 °C | |||||||||||||
Temperature stability | ±0.5 °C | |||||||||||||
Cooling capacity (Medium: Water Glycol) |
|
|
||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||
|
||||||||||||||
Pump capacity flow rate | 60 l/min | |||||||||||||
Pump capacity flow pressure | 0.5 ... 6 bar | |||||||||||||
Filling volume | 39 ... 47 l | |||||||||||||
Dimensions (W × L × H) |
78 x 85 x 148 cm |
Order No. | 9 666 110.07 | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -20 ... +40 °C | |||||||||||||
Temperature stability | ±0.5 °C | |||||||||||||
Cooling capacity (Medium: Water Glycol) |
|
|
||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||
|
||||||||||||||
Pump capacity flow rate | 60 l/min | |||||||||||||
Pump capacity flow pressure | 0.5 ... 6 bar | |||||||||||||
Filling volume | 39 ... 47 l | |||||||||||||
Dimensions (W × L × H) |
78 x 85 x 148 cm |
Product Features
- Ergonomic design and easy operation
- Splash-proof keypad
- Large, bright LED display
- Permissible temperature in return line +80°C
- Easy filling from the top with hinged protective lid
- Low liquid level protection with optical and audible alarm signal
- Integrated stainless steel bath tanks
- Front drain
- No side vents, instruments can be placed right next to other equipment
- RS232 interface for PC connection
- IP class according to IEC 60529: 21
- Alarm output, potential-free change-over contact (max. 30 VA)
- Pressure Indicator
- By-pass valve to adjust pump pressure
Dimensions (W × L × H) |
78 x 85 x 148 cm |
---|---|
Filling volume | 39 ... 47 l |
Weight | 248 kg |
Pump connections | G1¼" male |
Pump connections | G1¼" male |
Barbed fittings inner diameter | 1" |
Working temperature range | -20 ... +40 °C |
---|---|
Temperature stability | ±0.5 °C |
Setting the resolution of the temperature display | 0.1 °C |
Temperature display resolution | 0.1 °C |
Ambient temperature | 5 ... 40 °C |
Return flow temperature max. | 80 °C |
Cooling capacity (Medium: Water Glycol) |
|
|
|||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||
|
|||||||||||||||
Pump capacity flow rate | 60 l/min | ||||||||||||||
Pump capacity flow pressure | 0.5 ... 6 bar | ||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||
Filling volume | 3000 g | ||||||||||||||
Carbon dioxide equivalent | 4.191 t |
Cooling capacity (Medium: Water Glycol) |
|
|
|||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||
|
|||||||||||||||
Pump capacity flow rate | 60 l/min | ||||||||||||||
Pump capacity flow pressure | 0.5 ... 6 bar | ||||||||||||||
Refrigerant stage 1 |
Refrigerant | R452A | |||||||||||||
Global Warming Potential for R452A | 2140 | ||||||||||||||
Filling volume | 3100 g | ||||||||||||||
Carbon dioxide equivalent | 6.634 t |
Bath tank | Stainless steel |
---|
Cooling of compressor | 1-stage Air |
---|
Sound pressure level | 74 dbA |
---|---|
Classification according to DIN12876-1 |
Classification I (NFL) |
IP Code according to IEC 60529 |
IP 21 |
Pump type | Immersion Pump |
Temperature control | PID1 |
---|---|
Temperature display | LED |
Temperature setting | Keypad |
230V/3PPE/60Hz Without Plug | 9666110.16 |
---|---|
400V/3PNPE/50Hz Plug 32A CEE | 9666110.07 |
2 each barbed fittings for tubing 1" inner dia (pumpconnections G1 1/4" male) |
Accessory for FL11006
Benefits
-
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory. -
Green technology.
Development consistently applied environmentally friendly materials and technologies. -
JULABO. Quality.
Highest standards of quality for a long product life. -
Quick start.
Individual JULABO consultation and comprehensive manuals at your disposal.