PRESTO Process Systems
working temperature range -93 °C to +250 °C
An entirely new generation of highly dynamic temperature control systems by JULABO. The new PRESTO systems are designed for precise temperature control as well as rapid temperature changes, making them ideal for reactor vessels, material stress tests, or temperature simulations. These instruments cover a working temperature of -93 to +250 °C with high cooling and heating capacity.
Highly efficient components give these instruments the ability to compensate for exothermic and endothermic reactions with extraordinary speed. Permanent internal monitoring and self-lubricating pumps contribute to the new PRESTO’s long service life. The integrated 5.7-inch color industrial-grade touch panel is one of the identifying characteristics of the new PRESTO. It gives the user a clear and well-organized view of important information while greatly improving user-friendliness. Once in operation, the new PRESTO® units are whisper quiet and barely audible in a laboratory. The new PRESTO® units are extremely robust and work reliably even if the ambient temperature climbs as high as +40 °C. Multiple interfaces permit remote control of the PRESTO® across networks and in superordinated control systems. Closed side panels without ventilation slits reduces to a minimum the amount of space needed to operate.
Product Features
- For highly precise, external temperature applications
- Rapid heating and cooling
- Wide working temperature ranges without changing fluids
- Highest performance with small footprint
- Space-saving design optimizes space utilization in your lab
- Ethernet interface
- SD-Card slot
- Highly dynamic ICC temperature control, stability to ±0.01 °C
- Electronic level indication
- Integrated programmer
- Unsurpassed power and efficiency
- Profibus DP (Accessory)
Product Overview
PRESTO A30/A38/A40/W40/A41/W41
Compact process systems down to -45 °C
The smaller PRESTO process systems are available with natural or synthetic refrigerants, depending on the model, and cover a working temperature range from -45 °C to +250 °C.
| Model | Add to compare PRESTO A30 |
Add to compare PRESTO A40 |
Add to compare PRESTO A38 |
Add to compare PRESTO A41 |
|---|---|---|---|---|
| Working temperature range (°C) | -30 ... +250 | -40 ... +250 | -45 ... +250 | -45 ... +250 |
| Temperature stability (°C) | ±0.01 ... ±0.05 | ±0.01 ... ±0.05 | ±0.01 ... ±0.05 | ±0.01 ... ±0.05 |
| Cooling capacity (kW) | 0.5 | 1.2 | 0.91 | 1.47 |
| Heating capacity (kW) | 2.7 | 2.7 | 2.7 | 2.7 |
| Pump capacity flow pressure (l/min) | 25 | 0 ... 40 | 0 ... 50 | 0 ... 50 |
| Pump capacity pressure (bar) | 0.5 | 0.1 ... 1.7 | 0.1 ... 1.6 | 0.1 ... 1.6 |
| Model | Add to compare PRESTO W40 |
Add to compare PRESTO W41 |
|---|---|---|
| Working temperature range (°C) | -40 ... +250 | -45 ... +250 |
| Temperature stability (°C) | ±0.01 ... ±0.05 | ±0.01 ... ±0.05 |
| Cooling capacity (kW) | 1.2 | 1.47 |
| Heating capacity (kW) | 2.7 | 2.7 |
| Pump capacity flow pressure (l/min) | 0 ... 40 | 0 ... 50 |
| Pump capacity pressure (bar) | 0.1 ... 1.7 | 0.1 ... 1.6 |
PRESTO A45/A45t
Air-cooled process systems down to -45 °C
The A45 air-cooled process system can be used flexibly and independently of cooling water supply. They compensate exothermic and endothermic reactions extremely quickly.
| Model | Add to compare PRESTO A45 |
Add to compare PRESTO A45t |
|---|---|---|
| Working temperature range (°C) | -45 ... +250 | -45 ... +250 |
| Temperature stability (°C) | ±0.05 ... ±0.1 | ±0.05 ... ±0.1 |
| Cooling capacity (kW) | 3.5 | 3.5 |
| Heating capacity (kW) | 6 | 12 |
| Pump capacity flow pressure (l/min) | 0 ... 80 | 0 ... 80 |
| Pump capacity pressure (bar) | 0.1 ... 3 | 0.1 ... 3 |
PRESTO W50/W50t
Water-cooled process system down to -50 °C
The rapid compensation of reactions even at higher ambient temperatures is the domain of the water-cooled W50 units. High heating and cooling capacity paired with powerful pumps.
| Model | Add to compare PRESTO W50 |
Add to compare PRESTO W50t |
|---|---|---|
| Working temperature range (°C) | -50 ... +250 | -50 ... +250 |
| Temperature stability (°C) | ±0.05 ... ±0.1 | ±0.05 ... ±0.1 |
| Cooling capacity (kW) | 7.5 | 7.5 |
| Heating capacity (kW) | 6 | 12 |
| Pump capacity flow pressure (l/min) | 0 ... 80 | 0 ... 80 |
| Pump capacity pressure (bar) | 0.1 ... 3 | 0.1 ... 3 |
PRESTO W55
Fast temperature control for larger applications
The powerful W55 regulates temperatures with high precision and convinces with faster cool-down and heat-up times. It is ideal for use in large external applications such as reactor temperature control, material stress testing or temperature simulation.
| Model | Add to compare PRESTO W55 |
|---|---|
| Working temperature range (°C) | -55 ... +250 |
| Temperature stability (°C) | ±0.05 ... ±0.1 |
| Cooling capacity (kW) | 15 |
| Heating capacity (kW) | 15 |
| Pump capacity flow pressure (l/min) | 0 ... 80 |
| Pump capacity pressure (bar) | 0.1 ... 3 |
PRESTO new generation: L52w / L56w
Energy-efficient process systems down to -56 °C with natural refrigerant
The modern, water-cooled process systems provide fast and efficient temperature control for demanding applications, thanks to their extremely powerful pumps. Operation is intuitive via the large touch display or through seamless integration into higher-level control systems.
| Model | Add to compare PRESTO L52w |
Add to compare PRESTO L56w |
|---|---|---|
| Working temperature range (°C) | -52 ... +250 | -56 ... 250 |
| Temperature stability (°C) | ±0.05 | ±0.05 |
| Cooling capacity (kW) | 25 | 55 |
| Heating capacity (kW) | 27 | 27 |
| Pump capacity flow pressure (l/min) | 0 ... 180 | 0 ... 180 |
| Pump capacity pressure (bar) | 0.1 ... 4.2 | 0.1 ... 4.2 |
PRESTO W56/W58
The most powerful, single-stage, highly dynamic temperature control systems
The water-cooled PRESTO W56, W56x, and W58x can temperature control applications with high performance requirements very quickly and efficiently. Even at low temperatures, these models have large power reserves for demanding external applications.
| Model | Add to compare PRESTO W56 |
Add to compare PRESTO W56x |
Add to compare PRESTO W58x |
|---|---|---|---|
| Working temperature range (°C) | -56 ... +250 | -50 ... +250 | -50 ... +250 |
| Temperature stability (°C) | ±0.05 ... ±0.1 | ±0.05 ... ±0.1 | ±0.05 ... ±0.1 |
| Cooling capacity (kW) | 25.8 | 25.8 | 33 |
| Heating capacity (kW) | 27 | 27 | 27 |
| Pump capacity flow pressure (l/min) | 0 ... 80 | 0 ... 70 | 0 ... 70 |
| Pump capacity pressure (bar) | 0.1 ... 3 | 0.1 ... 5.5 | 0.1 ... 5.5 |
PRESTO A70/A80/W80
2-stage process system for low temperatures
As air- or water-cooled versions, the units with 2-stage refrigeration unit offer high cooling and heating capacities for lowest temperatures down to -80 °C.
| Model | Add to compare PRESTO A70 |
Add to compare PRESTO A80 |
Add to compare PRESTO W80 |
Add to compare PRESTO A80t |
|---|---|---|---|---|
| Working temperature range (°C) | -75 ... +250 | -80 ... +250 | -80 ... +250 | -80 ... +250 |
| Temperature stability (°C) | ±0.01 ... ±0.05 | ±0.01 ... ±0.05 | ±0.01 ... ±0.05 | ±0.01 ... ±0.05 |
| Cooling capacity (kW) | 1.12 | 1.2 | 1.2 | 1.2 |
| Heating capacity (kW) | 1.8 | 1.8 | 1.8 | 3.4 |
| Pump capacity flow pressure (l/min) | 0 ... 40 | 0 ... 40 | 0 ... 40 | 0 ... 40 |
| Pump capacity pressure (bar) | 0.1 ... 1.7 | 0.1 ... 1.7 | 0.1 ... 1.7 | 0.1 ... 1.7 |
| Model | Add to compare PRESTO W80t |
|---|---|
| Working temperature range (°C) | -80 ... +250 |
| Temperature stability (°C) | ±0.01 ... ±0.05 |
| Cooling capacity (kW) | 1.2 |
| Heating capacity (kW) | 3.4 |
| Pump capacity flow pressure (l/min) | 0 ... 40 |
| Pump capacity pressure (bar) | 0.1 ... 1.7 |
PRESTO A85/A85t/W85/W85t
Powerhouses among the process system
High cooling capacities enable extremely low temperatures down to -85 °C possible. The high heating capacity, particularly with the A85t and the W85t, provides even more flexibility in the application.
| Model | Add to compare PRESTO A85 |
Add to compare PRESTO W85 |
Add to compare PRESTO A85t |
Add to compare PRESTO W85t |
|---|---|---|---|---|
| Working temperature range (°C) | -85 ... +250 | -85 ... +250 | -85 ... +250 | -85 ... +250 |
| Temperature stability (°C) | ±0.05 ... ±0.1 | ±0.05 ... ±0.1 | ±0.05 ... ±0.1 | ±0.05 ... ±0.1 |
| Cooling capacity (kW) | 2.5 | 2.5 | 2.5 | 2.5 |
| Heating capacity (kW) | 6 | 6 | 15 | 15 |
| Pump capacity flow pressure (l/min) | 0 ... 80 | 0 ... 80 | 0 ... 80 | 0 ... 80 |
| Pump capacity pressure (bar) | 0.1 ... 3 | 0.1 ... 3 | 0.1 ... 3 | 0.1 ... 3 |
PRESTO W91
11 kW cooling capacity for dynamic temperature change down to -91 °C
Best heating capacity combined with high cooling capacity – those are the key features of the W91 units. The units are just as ready for embedding into pilot plants as they are for use in material and component testing.
| Model | Add to compare PRESTO W91tt |
Add to compare PRESTO W91x |
Add to compare PRESTO W91ttx |
Add to compare PRESTO W91 |
|---|---|---|---|---|
| Working temperature range (°C) | -91 ... +250 | -91 ... +250 | -91 ... +250 | -91 ... +250 |
| Temperature stability (°C) | ±0.05 ... ±0.2 | ±0.05 ... ±0.2 | ±0.05 ... ±0.2 | ±0.05 ... ±0.2 |
| Cooling capacity (kW) | 11 | 11 | 11 | 11 |
| Heating capacity (kW) | 36 | 18 | 36 | 18 |
| Pump capacity flow pressure (l/min) | 0 ... 80 | 0 ... 70 | 0 ... 70 | 0 ... 80 |
| Pump capacity pressure (bar) | 0.1 ... 3 | 0.1 ... 5.5 | 0.1 ... 5.5 | 0.1 ... 3 |
PRESTO W92
Highest cooling capacity of 27 kW and heating capacity up to 36 kW
The W92 class process systems are extremely powerful and can also simulate extreme environmental conditions. They are used, for example, in the temperature control of vacuum chambers for component testing in the aerospace industry.
| Model | Add to compare PRESTO W92tt |
Add to compare PRESTO W92x |
Add to compare PRESTO W92 |
Add to compare PRESTO W92ttx |
|---|---|---|---|---|
| Working temperature range (°C) | -92 ... +250 | -92 ... +250 | -92 ... +250 | -92 ... +250 |
| Temperature stability (°C) | ±0.05 ... ±0.2 | ±0.05 ... ±0.2 | ±0.05 ... ±0.2 | ±0.05 ... ±0.2 |
| Cooling capacity (kW) | 27 | 27 | 27 | 27 |
| Heating capacity (kW) | 36 | 18 | 18 | 36 |
| Pump capacity flow pressure (l/min) | 0 ... 80 | 0 ... 70 | 0 ... 80 | 0 ... 70 |
| Pump capacity pressure (bar) | 0.1 ... 3 | 0.1 ... 5.5 | 0.1 ... 3 | 0.1 ... 5.5 |
PRESTO W93
Full cooling capacity in the low temperature range
W93 process systems offer users high cooling capacity for dynamic applications even in the lowest temperature ranges. They work with natural refrigerants and are also very energy efficient thanks to state-of-the-art technologies.
| Model | Add to compare PRESTO W93 |
Add to compare PRESTO W93x |
|---|---|---|
| Working temperature range (°C) | -93 ... +250 | -93 ... +250 |
| Temperature stability (°C) | ±0.05 ... ±0.2 | ±0.05 ... ±0.2 |
| Cooling capacity (kW) | 21.5 | 21 |
| Heating capacity (kW) | 27 | 27 |
| Pump capacity flow pressure (l/min) | 0 ... 80 | 0 ... 70 |
| Pump capacity pressure (bar) | 0.1 ... 3 | 0.1 ... 5.5 |