FL Recirculating Coolers
Chill Environmentally Friendly and Economical
The FL series offers a new generation of chillers for routine cooling applications within the laboratory and industry. The temperature stability of the PID control is ±0.5°C.
All units can easily be cleaned and are provided with a splash water proof keypad with LED temperature indication. On the front of the units there is an RS232 interface as well as an alarm shutdown. The filling port is easily accessible placed on the top under a lift-up cover. Another hinged tray serves as a file for the operating manual or other documents concerning the installation. The removable venting grid allows an easy cleaning of the condenser, the drain tap is easily accessible behind the grid. All models include an easily visible level indication. Another advantage is the venting slots are on the front and rear and therefore the units can be placed directly one beside the other (space saving).
Product Features
- Large, bright LED display
- Powerful immersion pumps, suitable for continuous operation
- Easy filling and Drain tap easily accessible
- Low liquid level protection with optical and audible alarm signal
- Front drain
- No side vents, instruments can be placed right next to other equipment
- RS232 interface for PC connection
- Pressure Indicator
Product Overview
FL Recirculating cooler with up to 4.3 kW of cooling capacity
The FL models shown here have higher cooling capacity, powerful circulating pumps, and internal bath volumes of up to 30 liters. 2 variants: Air-cooled (FL) and water-cooled (FLW).
| Model | Add to compare FL4003 |
Add to compare FLW4003 |
Add to compare FL4006 |
Add to compare FLW4006 |
|---|---|---|---|---|
| Working temperature range (°C) | -20 ... 40 | -20 ... 40 | -20 ... 40 | -15 ... 40 |
| Temperature stability (°C) | ±0.5 | ±0.5 | ±0.5 | ±0.5 |
| Cooling capacity (kW) | 4 | 4.3 | 4 | 4 |
| Pump capacity flow rate (l/min) | 40 | 40 | 60 | 60 |
| Pump capacity pressure (bar) | 0.5 ... 3 | 0.5 ... 3 | 0.5 ... 6 | 0.5 ... 6 |
FL Recirculating cooler with up to 20 kW of cooling capacity
Models with particularly high power reserves
The powerful FL models are suitable for a wide range of cooling tasks in industrial environments, such as removal of large process heat. 2 variants: Air-cooled (FL) and water-cooled (FLW).
| Model | Add to compare FL7006 |
Add to compare FLW7006 |
Add to compare FL11006 |
Add to compare FLW11006 |
|---|---|---|---|---|
| Working temperature range (°C) | -20 ... 40 | -20 ... 40 | -20 ... 40 | -20 ... 40 |
| Temperature stability (°C) | ±0.5 | ±0.5 | ±0.5 | ±0.5 |
| Cooling capacity (kW) | 7 | 7.4 | 11 | 11.5 |
| Pump capacity flow rate (l/min) | 60 | 60 | 60 | 60 |
| Pump capacity pressure (bar) | 0.5 ... 6 | 0.5 ... 6 | 0.5 ... 6 | 0.5 ... 6 |