CORIO C Heating Immersion Circulator
The new generation of laboratory circulators
The CORIO C Immersion Circulator is the basic model of the CORIO circulator portfolio. The bath attachment clamp is included in delivery and facilitates mounting of the circulator on any bath tank up to 30 liters.
Request a quote
| Order No. | 9 011 000.04 | |
|---|---|---|
| Working temperature range | +20 ... +100 °C | |
| Temperature stability | ±0.03 °C | |
|
Dimensions (W × L × H) |
13.2 x 16 x 36.2 cm | |
| Order No. | 9 011 000.04 | |
|---|---|---|
| Working temperature range | +20 ... +100 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 2 kW | |
|
Dimensions (W × L × H) |
13.2 x 16 x 36.2 cm | |
| Order No. | 9 011 000.05 | |
|---|---|---|
| Working temperature range | +20 ... +100 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 2 kW | |
|
Dimensions (W × L × H) |
13.2 x 16 x 36.2 cm | |
| Order No. | 9 011 000.05 | |
|---|---|---|
| Working temperature range | +20 ... +100 °C | |
| Temperature stability | ±0.03 °C | |
|
Dimensions (W × L × H) |
13.2 x 16 x 36.2 cm | |
| Order No. | 9 011 000.33 | |
|---|---|---|
| Working temperature range | +20 ... +100 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 1.6 kW | |
|
Dimensions (W × L × H) |
13.2 x 16 x 36.2 cm | |
| Order No. | 9 011 000.33 | |
|---|---|---|
| Working temperature range | +20 ... +100 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 2 kW | |
|
Dimensions (W × L × H) |
13.2 x 16 x 36.2 cm | |
| Order No. | 9 011 000.33 | |
|---|---|---|
| Working temperature range | +20 ... +100 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 2 kW | |
|
Dimensions (W × L × H) |
13.2 x 16 x 36.2 cm | |
| Order No. | 9 011 000.33.chn | |
|---|---|---|
| Working temperature range | +20 ... +100 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 2 kW | |
|
Dimensions (W × L × H) |
13.2 x 16 x 36.2 cm | |
| Order No. | 9 011 000.33.chn | |
|---|---|---|
| Working temperature range | +20 ... +100 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 2 kW | |
|
Dimensions (W × L × H) |
13.2 x 16 x 36.2 cm | |
| Order No. | 9 011 000.22 | |
|---|---|---|
| Working temperature range | +20 ... +100 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 0.8 kW | |
|
Dimensions (W × L × H) |
13.2 x 16 x 36.2 cm | |
| Order No. | 9 011 000.22 | |
|---|---|---|
| Working temperature range | +20 ... +100 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 0.8 kW | |
|
Dimensions (W × L × H) |
13.2 x 16 x 36.2 cm | |
| Order No. | 9 011 000.22 | |
|---|---|---|
| Working temperature range | +20 ... +100 °C | |
| Temperature stability | ±0.03 °C | |
| Heating capacity | 1 kW | |
|
Dimensions (W × L × H) |
13.2 x 16 x 36.2 cm | |
Product Features
- Precise temperature control
- For internal standard applications
- For bath tanks with a max. filling volume of 30 liters
- Bright, white, easy to read display
- Very quiet
- Easy operation
- Class I (NFL) according to DIN 12876-1
- For bath tanks with a max. filling volume of 50 liters
- Class III (FL) according to DIN 12876-1
- Powerful and infinitely adjustable pressure pump
|
Dimensions (W × L × H) |
13.2 x 16 x 36.2 cm |
|---|---|
| Usable immersion depth | 16.6 cm |
| Weight | 1.9 kg |
| Working temperature range | +20 ... +100 °C |
|---|---|
| Temperature stability | ±0.03 °C |
| Setting the resolution of the temperature display | 0.1 °C |
| Temperature display resolution | 0.01 ... 0.1 °C |
| Ambient temperature | +5 ... +40 °C |
| Heating capacity | 2 kW |
|---|---|
| Viscosity max. | 1 cST |
| Circulation capacity flow rate | 6 l/min |
| Heating capacity | 2 kW |
|---|---|
| Viscosity max. | 1 cST |
| Circulation capacity flow rate | 6 l/min |
| Heating capacity | 1.6 kW |
|---|---|
| Viscosity max. | 1 cST |
| Circulation capacity flow rate | 6 l/min |
| Heating capacity | 2 kW |
|---|---|
| Viscosity max. | 1 cST |
| Circulation capacity flow rate | 6 l/min |
| Heating capacity | 2 kW |
|---|---|
| Viscosity max. | 1 cST |
| Circulation capacity flow rate | 6 l/min |
| Heating capacity | 2 kW |
|---|---|
| Viscosity max. | 1 cST |
| Circulation capacity flow rate | 6 l/min |
| Heating capacity | 2 kW |
|---|---|
| Viscosity max. | 1 cST |
| Circulation capacity flow rate | 6 l/min |
| Heating capacity | 0.8 kW |
|---|---|
| Viscosity max. | 1 cST |
| Circulation capacity flow rate | 6 l/min |
| Heating capacity | 0.8 kW |
|---|---|
| Viscosity max. | 1 cST |
| Circulation capacity flow rate | 6 l/min |
| Heating capacity | 1 kW |
|---|---|
| Viscosity max. | 1 cST |
| Circulation capacity flow rate | 6 l/min |
| Cooling coil | accessory |
|---|
| Classification according to DIN12876-1 |
Classification I (NFL) |
|---|---|
| IP Code according to IEC 60529 |
IP 21 |
| Pump type | Immersion Pump |
| Temperature control | PID1 |
|---|---|
| Absolute temperature calibration | 1 Point Calibration |
| Temperature display | LED |
| Temperature setting | Keypad |
| 230V/50-60Hz UK Plug Type BS1363A | 9011000.04 |
|---|---|
| 230V/50-60Hz CH Plug Type SEV 1011 | 9011000.05 |
| 230V/50-60Hz Schuko Plug - CEE 7/4 Plug Type F | 9011000.33 |
| 230V/50-60Hz CN Plug | 9011000.33.chn |
| 100-115V/50-60Hz Nema N5-15 Plug | 9011000.22 |
Accessory for CORIO C
Benefits
-
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory. -
Green technology.
Development consistently applied environmentally friendly materials and technologies. -
Internal. External.
The pump is controlled via a lever located directly below the display. Easily change between internal and external circulation. -
JULABO. Quality.
Highest standards of quality for a long product life.
-
Modern. Reliable.
High-grade components in every JULABO Circulator – platinum sensors, proven motor technology, CAN-Bus communication and much more. -
Satisfied customers.
11 subsidiaries and more than 100 partners worldwide guarantee fast and qualified JULABO support. -
Services 24/7.
Around the clock availability. You can find suitable accessories, data sheets, manuals, case studies, and more at www.julabo.com. -
Quick start.
Individual JULABO consultation and comprehensive manuals at your disposal. -
Timer. Integrated.
CORIO circulators include an integrated timer function. When the set time has elapsed, a signal sounds and the device switches off. Setting range: 0 ... 999 minutes. -
Brilliant.
Very bright display makes it easy to read even from a distance. -
Connection. Easy.
Inclined pump connections (M16×1) facilitate the connection of applications. Each unit includes 2 barbed fittings of 8/12 mm diameter each. -
Everything at the front.
All operating controls and safety functions are accessed easily and comfortably from the front. -
Exact.
You can rely on it. PID1 control and 'Active Cooling Control' make the new CORIO precise and perfect. -
Locked in.
The lockable power plug guarantees safe connection. More process safety. -
Switch on. And off you go.
Intelligent operating concept. Ready for operation with just a few quick and easy steps. -
Early warning system for low liquid level
Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down