Print

Flow measurement and Flow control

Flow meter MID DN15 8980731

  • Measurement technology: magnetic-inductive
  • Suitable Fluids: Thermal HL30, Wasser-Glykol
  • Working temperature range: -40°C…+130°C
  • Accuracy: 1.56 … 0.51 %
  • Flow rate: 1 … 100 l/min 1)
  • Fluid connectors: M30x1.5 male 2)
  • Tubing diameter: DN15
  • Output signal: 4 ... 20 mA
  • Mains power supply: 100-230V/50-60Hz
  • Power Supply and 2.5m ...
Order No.: 8980731

Flow meter MID DN25 8980732

Flow meter MID DN25 8980732 from JULABO View 1
  • Measurement technology: magnetic-inductive
  • Suitable Fluids: Thermal HL30, Wasser-Glykol
  • Working temperature range: -40°C … +130°C
  • Accuracy: 3.21 … 0.53 %
  • Flow rate: 1 … 300 l/min 1)
  • Fluid connectors: M30x1.5 male 2)
  • Tubing diameter: DN25
  • Output signal: 4 ... 20 mA
  • Mains power supply: 100-230V/50-60Hz
  • Power Supply and 2.5m ...
Order No.: 8980732

Flow meter CORIOLIS 1 DN15 8980735

  • Measurement technology: Coriolis
  • Suitable Fluids: Thermal HL30, HL60, HL80, Water-Glykol, Fluorinert ®
  • Working temperature range: -40 °C … +150 °C
  • Accuracy: 1.10 … 0.10 %
  • Flow rate: 1 … 100 l/min 1)
  • Fluid connectors: M30x1.5 male 2)
  • Tubing diameter: DN15
  • Output signal: 4 ... ...
Order No.: 8980735

Flow meter CORIOLIS 1 DN25 8980736

Flow meter CORIOLIS 1 DN25 8980736 from JULABO View 1
  • Measurement technology: Coriolis
  • Suitable Fluids: Thermal HL30, HL60, HL80, Water-Glykol, Fluorinert ®
  • Working temperature range: -40 °C … +150 °C
  • Accuracy: 3.01 … 0.10 %
  • Flow rate: 1 … 300 l/min 1)
  • Fluid connectors: M30x1.5 male 2)
  • Tubing diameter: DN25
  • Output signal: 4 ... ...
Order No.: 8980736

Flow meter CORIOLIS 2 DN25 8980737

  • Measurement technology: Coriolis
  • Suitable Fluids: Thermal HL30, HL60, HL80, Water-Glykol, Fluorinert ®
  • Working temperature range: -90°C … +240°C
  • Accuracy: 0.85 … 0.10 %
  • Flow rate: 1 … 300 l/min 1)
  • Fluid connectors: M30x1.5 male 2)
  • Tubing diameter: DN25
  • Output signal: 4 ... 20 ...
Order No.: 8980737

Fluid-Bypass, electronically controlled, -92…+250°C M30 x 1.5 24VDC / 0.5A 8980780

  • Working temperature range: -92…+250°C
  • Control Instument: high-resolution stepper motor valve
  • Suitable Fluids: THERMAL HL30/HL60/HL80, Fluorinert ®, Water-Glycol
  • Flow control range: 0.2 … 100 Lpm *3)
  • Fluid connectors: M30 x 1.5 male *1) *2)
  • Power supply: via PRESTO (24 VDC / 0.5A)
  • Control input: CAN connector to connect to ...
Order No.: 8980780

Connection Kit for Fluid-Bypass for PRESTO A45, A45t, W50, W50t for assembly by customer 8980781

Connection Kit for Fluid-Bypass for PRESTO A45, A45t, W50, W50t for assembly by customer 8980781 from JULABO View 1
  • All necessary components to fix the Fluid-Bypass to the PRESTO
  • Stainless steel tubing to connect Fluid-Bypass to PRESTO
  • Insulation, temperature resistant
  • Digital control cable
Order No.: 8980781

This accessory is suitable for:

PRESTO A45, PRESTO A45t, PRESTO W50, PRESTO W50t

Connection Kit for Fluid-Bypass for PRESTO W55 for assembly by customer 8980783

Connection Kit for Fluid-Bypass for PRESTO W55 for assembly by customer 8980783 from JULABO View 1
  • All necessary components to fix the Fluid-Bypass to the PRESTO
  • Stainless steel tubing to connect Fluid-Bypass to PRESTO
  • Insulation, temperature resistant
  • Digital control cable
Order No.: 8980783

This accessory is suitable for:

PRESTO W55

Factory Installation of Fluid-Bypass and Connection Kit to PRESTO A45, A45t, W50, W50t, W55 8980784

Factory Installation of Fluid-Bypass and Connection Kit to PRESTO A45, A45t, W50, W50t, W55 8980784 from JULABO View 1
Order No.: 8980784

This accessory is suitable for:

PRESTO A45, PRESTO A45t, PRESTO W50, PRESTO W50t

Contact

JULABO GmbH
Gerhard-Juchheim-Strasse 1
77960 Seelbach / Germany
Tel: +49 7823 51-0
info.de@julabo.com
www.julabo.com
Contact form

Catalog request
Order our brochures!