FP89-ME Ultra-Low Refrigerated / Heating Circulator
Ultra-low Refrigerated Circulator with 2-stage cascade-cooling
The Ultra-Low Refrigerated Circulators of the TopTech Series are equipped with a dual-stage cascade refrigeration system for continuous operation of internal and external temperature applications.
Models with ME circulator
- Heated bath cover plate to prevent condensation or ice build-up
- Pressure pump up to 0.45 bar, electronically adjustable in steps
- ACC Active Cooling Control across the entire temperature range
- Compact design Note: FP models feature an energy-saving proportional cooling control.
Order No. | 9 162 689.03 | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -90 ... +100 °C | |||||||||||||||
Temperature stability | +/-0.02 °C | |||||||||||||||
Heating capacity | 1.2 kW | |||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||
|
||||||||||||||||
Pump capacity flow rate | 11 ... 16 l/min | |||||||||||||||
Pump capacity flow pressure | 0.23 ... 0.45 bar | |||||||||||||||
Usable bath opening (W x L / D) |
13 x 15 / 16 cm | |||||||||||||||
Filling volume | 5.5 ... 8 l | |||||||||||||||
Dimensions (W × L × H) |
55 x 60 x 90 cm |
Order No. | 9 162 689.13 | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -90 ... +100 °C | |||||||||||||||
Temperature stability | +/-0.02 °C | |||||||||||||||
Heating capacity | 1.2 kW | |||||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||||
|
||||||||||||||||
Pump capacity flow rate | 11 ... 16 l/min | |||||||||||||||
Pump capacity flow pressure | 0.23 ... 0.45 bar | |||||||||||||||
Usable bath opening (W x L / D) |
13 x 15 / 16 cm | |||||||||||||||
Filling volume | 5.5 ... 8 l | |||||||||||||||
Dimensions (W × L × H) |
55 x 60 x 90 cm |
Product Features
- PID3 cascade temperature control
- RS232 interface for online communication
- Integrated programmer for 10 program steps
Dimensions (W × L × H) |
55 x 60 x 90 cm |
---|---|
Filling volume | 5.5 ... 8 l |
Weight | 137 kg |
Pump connections | M16x1 male |
Pump connections | M16x1 male |
Barbed fittings inner diameter | 8/12 mm |
Working temperature range | -90 ... +100 °C |
---|---|
Temperature stability | +/-0.02 °C |
Setting the resolution of the temperature display | 0.01 °C |
Temperature display resolution | 0.01 °C |
Ambient temperature | +5.0 ... +40.0 °C |
Heating capacity | 1.2 kW | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||
|
|||||||||||||||||
Pump capacity flow rate | 11 ... 16 l/min | ||||||||||||||||
Pump capacity flow pressure | 0.23 ... 0.45 bar | ||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R404A | |||||||||||||||
Global Warming Potential for R404A | 3922 | ||||||||||||||||
Filling volume | 500 g | ||||||||||||||||
Carbon dioxide equivalent | 1.961 t |
Heating capacity | 1.2 kW | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||||
|
|||||||||||||||||
Pump capacity flow rate | 11 ... 16 l/min | ||||||||||||||||
Pump capacity flow pressure | 0.23 ... 0.45 bar | ||||||||||||||||
Viscosity max. | 50 cST | ||||||||||||||||
Refrigerant stage 1 |
Refrigerant | R404A | |||||||||||||||
Global Warming Potential for R404A | 3922 | ||||||||||||||||
Filling volume | 500 g | ||||||||||||||||
Carbon dioxide equivalent | 1.961 t |
Bath tank | Stainless steel |
---|---|
Bath cover | integrated |
Usable bath opening (W x L / D) |
13 x 15 / 16 cm |
Cooling of compressor | 2-stage Air |
---|
Classification according to DIN12876-1 |
Classification III (FL) |
---|---|
IP Code according to IEC 60529 |
IP 21 |
Pump type | Immersion Pump |
External pt100 sensor connection | integrated |
---|---|
Integrated programmer | 1x10 steps |
Temperature control | PID3 |
Absolute temperature calibration | 3 Point Calibration |
Temperature display | VFD |
Temperature setting | Keypad |
230V/50Hz Schuko Plug - CEE 7/4 Plug Type F | 9162689.03 |
---|---|
230V/60Hz Nema N6-20 Plug | 9162689.13 |
2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) |
Accessory for FP89-ME
Benefits
-
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory. -
Green technology.
Development consistently applied environmentally friendly materials and technologies. -
JULABO. Quality.
Highest standards of quality for a long product life. -
Quick start.
Individual JULABO consultation and comprehensive manuals at your disposal.