FLW7006 Powerful recirculating cooler
Models with particularly high power reserves
The powerful FL models are suitable for a wide range of cooling tasks in industrial environments, such as removal of large process heat. 2 variants: Air-cooled (FL) and water-cooled (FLW).
Optional heating function
On request, we also offer our FL recirculating chillers with an additional integrated heating function and other special solutions. Our product experts will be happy to advise you individually in order to design a temperature control unit that is exactly right for your needs. Just give us a call!
Order No. | 9676070.07 | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -20 ... +40 °C | |||||||||||||||||||||
Temperature stability | ±0.5 °C | |||||||||||||||||||||
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
||||||||||||||||||||||
Pump capacity flow rate | 60 l/min | |||||||||||||||||||||
Pump capacity flow pressure | 0.5 ... 6 bar | |||||||||||||||||||||
Filling volume | 39 ... 47 l | |||||||||||||||||||||
Dimensions
(W × L × H) |
78 x 85 x 148 cm |
Product Features
- Ergonomic design and easy operation
- Splash-proof keypad
- Large, bright LED display
- Permissible temperature in return line +80°C
- Easy filling from the top with hinged protective lid
- Low liquid level protection with optical and audible alarm signal
- Integrated stainless steel bath tanks
- Front drain
- No side vents, instruments can be placed right next to other equipment
- RS232 interface for PC connection
- IP class according to IEC 60529: 21
- Alarm output, potential-free change-over contact (max. 30 VA)
- Pressure Indicator
Technical data for FLW7006
Dimensions (W × L × H) |
78 x 85 x 148 cm |
---|---|
Filling volume | 39 ... 47 l |
Weight | 232 kg |
Pump connections | G1¼" male |
Cooling Water Connection | G¾ in |
Barbed fittings inner diameter | 1" |
Working temperature range | -20 ... +40 °C |
---|---|
Temperature stability | ±0.5 °C |
Setting the resolution of the temperature display | 0.1 °C |
Setting the resolution of the temperature display | 0.1 °C |
Ambient temperature | +5 ... +40 °C |
Return flow temperature max. | 80 °C |
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
||||||||||||||||||||||
Pump capacity flow rate | 60 l/min | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pump capacity flow pressure | 0.5 ... 6 bar | |||||||||||||||||||||
Power consumption | 14 A |
Bath tank | Stainless steel |
---|
Cooling of compressor | 1-stage Water |
---|---|
Cooling water pressure max. | 6 bar |
to provide full cooling capacity according to catalog values | |
Cooling water temperature range | 20 °C |
---|---|
Cooling water difference pressure | 2 bar |
Cooling water consumption | 11.6 l/min |
Sound pressure level | 74 dbA |
---|---|
Classification according to DIN12876-1 |
Classification I (NFL) |
IP Code according to IEC 60529 |
IP 21 |
Pump type | Immersion Pump |
Interfaces | Alarm output / RS232 / Stakei |
---|---|
Temperature control | PID1 |
Temperature display | LED |
Temperature setting | Keypad |
9676070.16 | 230V/3PPE/60Hz (Without Plug) (R449A) |
---|---|
9676070.07 | 400V/3PNPE/50Hz (Plug 16A CEE) (R452A) |
2 each barbed fittings for tubing 1" inner dia (pumpconnections G1 1/4" male). |
Accessory for FLW7006
Downloads for FLW7006
We would also be happy to send you our printed catalogs and brochures by post.
Request brochureFLW7006 Benefits
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
Green technology.
Development consistently applied environmentally friendly materials and technologies.
JULABO. Quality.
Highest standards of quality for a long product life.
Quick start.
Individual JULABO consultation and comprehensive manuals at your disposal.