FK30-SL Calibration Bath
with integrated cooling machine for working temperatures up to -30 °C
The calibration baths in this category feature an integrated refrigeration unit and are suitable for calibration applications to -30 °C. The bath cover with openings and Viton® sleeves is already included in delivery for all models.
Request a quoteOrder No. | 9 352 627.02 | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -30 ... +200 °C | |||||||||
Temperature stability | ±0.005 °C | |||||||||
Heating capacity | 1 kW | |||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||
|
||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | |||||||||
Usable bath opening (W x L / D) |
12 x 17 / cm | |||||||||
Filling volume | 14 l | |||||||||
Dimensions (W × L × H) |
32 x 45 x 79 cm |
Order No. | 9 352 627.03 | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -30 ... +200 °C | |||||||||
Temperature stability | ±0.005 °C | |||||||||
Heating capacity | 2 kW | |||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||
|
||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | |||||||||
Usable bath opening (W x L / D) |
12 x 17 / cm | |||||||||
Filling volume | 14 l | |||||||||
Dimensions (W × L × H) |
32 x 45 x 79 cm |
Order No. | 9 352 627.04 | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -30 ... +200 °C | |||||||||
Temperature stability | ±0.005 °C | |||||||||
Heating capacity | 2 kW | |||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||
|
||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | |||||||||
Usable bath opening (W x L / D) |
12 x 17 / cm | |||||||||
Filling volume | 14 l | |||||||||
Dimensions (W × L × H) |
32 x 45 x 79 cm |
Product Features
- VFD COMFORT DISPLAY
- LCD DIALOG DISPLAY backlit for convenient interactive operation
- Keypad for setpoints, warning/safety values and menu functions
- ICC (Intelligent Cascade Control), self-optimizing temperature control
- TCF Temperature Control Features to optimize the control behavior
- ATC3 3-Point-Calibration
- Pt100 External sensor connection for measurement and control
- SMART PUMP, electronically adjustable pump stages
- Adjustable high temperature cut-out, visible via display
- Integrated programmer for 6 x 60 program steps
- Highest temperature stability to ±0.005 °C (±0.02 °C at +200 °C)
- Temperature uniformity better than ±0.01 °C
- Optional Pt100 sensor for reference temperature measurements
- Temperature chamber with overflow at maximum liquid level
- Active Cooling Control
Dimensions (W × L × H) |
32 x 45 x 79 cm |
---|---|
Filling volume | 14 l |
Usable immersion depth | 17 cm |
Weight | 48 kg |
Working temperature range | -30 ... +200 °C |
---|---|
Temperature stability | ±0.005 °C |
Temperature display resolution | 0.01 °C |
Ambient temperature | 5 ... 40 °C |
Heating capacity | 1 kW | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||
|
|||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | ||||||||||
Maximum suction | 0.2 ... 0.4 bar | ||||||||||
Viscosity max. | 70 cST | ||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||
Global Warming Potential for R134a | 1430 | ||||||||||
Filling volume | 163 g | ||||||||||
Carbon dioxide equivalent | 0.233 t |
Heating capacity | 2 kW | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||
|
|||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | ||||||||||
Maximum suction | 0.2 ... 0.4 bar | ||||||||||
Viscosity max. | 70 cST | ||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||
Global Warming Potential for R134a | 1430 | ||||||||||
Filling volume | 163 g | ||||||||||
Carbon dioxide equivalent | 0.233 t |
Heating capacity | 2 kW | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||
|
|||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | ||||||||||
Maximum suction | 0.2 ... 0.4 bar | ||||||||||
Viscosity max. | 70 cST | ||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||
Global Warming Potential for R134a | 1430 | ||||||||||
Filling volume | 163 g | ||||||||||
Carbon dioxide equivalent | 0.233 t |
Bath tank | Stainless steel |
---|---|
Bath cover | integrated |
Usable bath opening (W x L / D) |
12 x 17 / cm |
Cooling coil | not available |
---|---|
Cooling of compressor | 1-stage Air |
Classification according to DIN12876-1 |
Classification III (FL) |
---|---|
IP Code according to IEC 60529 |
IP 21 |
Pump type | Immersion Pump |
Digital interface | Profibus optional |
---|---|
External pt100 sensor connection | integrated |
Integrated programmer | 6x60 steps |
Temperature control | ICC |
Absolute temperature calibration | 3 Point Calibration |
Temperature display | VFD |
Temperature setting | Keypad |
115V/60Hz Nema N5-15 Plug | 9352627.02 |
---|---|
230V/50Hz Schuko Plug - CEE 7/4 Plug Type F | 9352627.03 |
230V/50Hz UK Plug Type BS1363A | 9352627.04 |
Including bath cover with 7 openings. |
Accessory for FK30-SL
Benefits
-
JULABO. Quality.
Highest standards of quality for a long product life. -
Green technology.
Development consistently applied environmentally friendly materials and technologies. -
Satisfied customers.
11 subsidiaries and more than 100 partners worldwide guarantee fast and qualified JULABO support. -
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.