PRESTO A80
Temperature Control System / Process System
Reactor temperature control, tests for all kinds of substances or temperature simulation – the new PRESTO are made for highly precise temperature control and rapid temperature changes. Highly efficient components allow extremely fast compensation of exothermic and endothermic reactions. Lab users benefit from high flow rates, constant pressure, and a controlled build-up of pump pressure. Permanent internal monitoring and self-lubricating pumps contribute to the new PRESTO’s long service life. The integrated 5.7’’ industrial touch screen displays all important information clearly and concisely enhancing ease of use considerably.
Your advantages
- For highly precise, external temperature applications
- Rapid heating and cooling
- Wide working temperature ranges without changing fluids
- Highest performance with small footprint
- Space-saving design optimizes space utilization in your lab
- 5,7” industrial color TFT touch screen
- USB (Host und Device)
- Ethernet
- SD-Card slot
- RS232
- Modbus
- RS485 (Accessory)
- Profibus DP (Accessory)
- Stand-by input
- Removable venting grid for simplified removal of dust
Technical Data
Order No. | 9420801 | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Category | Temperature Control PRESTO | ||||||||||||||||
Working temperature range (°C) | -80 ... +250 | ||||||||||||||||
Temperature control | ICC | ||||||||||||||||
Temperature stability (°C) | ±0.01 ... ±0.05 | ||||||||||||||||
Setting / display resolution | 0.01 °C | ||||||||||||||||
Integrated programmer | 8x60 steps | ||||||||||||||||
Temperature Display | TFT Touchscreen | ||||||||||||||||
Heating capacity (kW) | 1.8 | ||||||||||||||||
Cooling capacity (Medium: JULABO Thermal | Ethanol) |
|
||||||||||||||||
Pump capacity flow rate (l/min) | 16 ... 40 | ||||||||||||||||
Pump capacity flow pressure (bar) | 0.3 ... 1.7 | ||||||||||||||||
Pump connections | M24x1.5 | ||||||||||||||||
Refrigerant stage 1 | R507 | ||||||||||||||||
Filling volume refrigerant stage 1 (g) | 1140 | ||||||||||||||||
Global Warming Potential for R507 | 3985 | ||||||||||||||||
Carbon dioxide equivalent stage 1 (t) | 4.543 | ||||||||||||||||
Refrigerant stage 2 | R23 | ||||||||||||||||
Filling volume refrigerant stage 2 (g) | 500 | ||||||||||||||||
Global Warming Potential for R23 | 14800 | ||||||||||||||||
Carbon dioxide equivalent stage 2 (t) | 7.4 | ||||||||||||||||
External Pt100 sensor connection | integrated | ||||||||||||||||
Digital interfaces |
RS232 SD memory card USB Ethernet Modbus Optional: RS485, Profibus |
||||||||||||||||
Analog connection input / output | Optional | ||||||||||||||||
Ambient temperature | 5 ... 40 °C | ||||||||||||||||
Dimensions W x L x H (cm) | 43 x 65 x 126 | ||||||||||||||||
Weight (kg) | 164 | ||||||||||||||||
Sound pressure level (distance 1 m) max. (dBA) | 68 | ||||||||||||||||
Process volume min. (active heat exchanger volume) liters | 3.9 (1.7) | ||||||||||||||||
Internal usable expansion vol. (liters) | 5.6 | ||||||||||||||||
Classification according to DIN12876-1 | Classification III (FL) | ||||||||||||||||
Cooling of compressor | 2-stage Air | ||||||||||||||||
Available voltage versions | 208V/60Hz (-10/+15%) / 15A / Nema N6-20 Plug 230V/50Hz (+/- 10%) / 13A / UK Plug type BS1363A 230V/50Hz (+/- 10%) / 16A / CEE 7/4 Plug type F |
Characteristics

TFT Display for comfortable user guidance, colored display of measurement values, graphs and control options, user-defined views

Touch screen for direct operation via display

Help menus and explanations in plain text for all control options, help messages and warning messages

Language selection for display of control options, notifications and warning messages via touchscreen

Administrator level for customizing instrument settings, user levels with limited permissions for fast and safe defined access, password protection, all levels adjustable

‘Intelligent Cascade Control’, automatic & self optimizing adjustment of PID control parameters, temperature stability ±0.01 °C ... <±0.2 °C

‘Temperature Control Features’, for individual optimization, access to all important control parameters, additional settings for band limit, limits, co-speedfactor etc.

External Pt100 sensor connection for precise measurement and control directly in the external application

‘Absolute Temperature Calibration’ for manual compensation of a temperature difference, 3-point calibration

Easily removable venting grid for quick and easy cleaning

‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures

Proportional cooling control for automatic adjustment of cooling power or temporary switch-off of compressor as needed to save up to 90 % energy in comparison to unregulated cooling machines

Reliable and consistent pump capacity, electronically adjustable pump stages or pressure value, automatic adjustment of pump capacity to viscosity

For the remote control of instruments via Ethernet networks, full access to all functions of the unit via a networkcapable PC

USB connection for data exchange (e.g. service data) or for wireless remote control via WirelessTEMP®

For data exchange (e.g. service data) via SD memory card

RS232 interface for PC connection, e.g. for data communication and recording of measured values

Integrated programmer for the execution of time and temperature dependant profiles, 8 temperature profiles with 60 steps max., with real time clock

Efficient components produce only a minimal sound decibel level

All connections as well supply and exhaust air are located at the front or rear, no venting grids on the sides, units can be placed close to each other or the application

Robust temperature control instrument, continuous operation even at ambient temperatures of up to +40 °C

Ergonomic design facilitates moving and positioning by one person

Backlit indicator for selected pump stages and filling volume

Maximum safety for applications, optical and audible signal when limits are exceeded.

Adjustable high temperature cut-off for internal tank and for integrated expansion vessel

Classification III (FL) according to DIN 12876-1

If an error occurs, the integrated Black-Box function permits fast diagnosis by the JULABO service team
Other characteristics
GB-version with 1050 W heater capacity available
Technical changes without prior notification.
Images may deviate from the original.
We would be pleased to submit a non-binding offer for the selected product or answer all pertinent questions.
click here for quotation request PRESTO A80Search
Contact
JULABO GmbH
Gerhard-Juchheim-Strasse 1
77960 Seelbach / Germany
Tel: +49 7823 51-0
info.de@julabo.com
www.julabo.com
Contact form