SE-26 Heating Circulator
Heating Circulator with stainless-steel bath tank for internal and external temperature applications
JULABO Heating Circulators with stainless steel bath tanks are mainly used for internal and external temperature tasks. The new range of these models now have increased capacities, allowing for temperature application of larger external systems, as well as open systems. Simultaneous temperature applications of smaller objects can also be carried out directly in the internal bath of the circulator. Models from the TopTech and HighTech Series’ are available with different bath sizes and features. Accessories for these units include test tube racks, bath covers etc. An integrated cooling coil is provided for temperature applications at near ambient or just below.
Your advantages
- VFD COMFORT DISPLAY
- Keypad for setpoints, warning/safety values and menu functions
- ICC (Intelligent Cascade Control), self-optimizing temperature control
- ATC3 3-Point-Calibration
- Pt100 External sensor connection for measurement and control
- SMART PUMP, electronically adjustable pump stages
- Early warning system for low liquid level (DBGM 203 06 059.8)
- Adjustable high temperature cut-out, visible via display
- RS232 interface for online communication
- Integrated programmer for 10 program steps
Technical Data
Order No. | 9252526 |
---|---|
Model series | HighTech |
Category | Heating Circulators |
Working temperature range (°C) | +20 ... +300 |
Temperature stability (°C) | ±0.01 |
Setting / display resolution | 0.01 °C |
Integrated programmer | 1x10 steps |
Temperature Display | VFD |
Heating capacity (kW) | 3 |
Pump capacity flow rate (l/min) | 22-26 |
Pump capacity flow pressure (bar) | 0.4-0.7 |
Pump capacity flow suction (bar) | 0.2-0.4 |
Bath opening / bath depth (W x L / D cm) | 22 x 30 / 20 |
Pump connections | M16x1 |
Barbed fittings diameter (inner dia. / mm) | 8 / 12 |
Filling volume (liters) | 26 |
External Pt100 sensor connection | integrated |
Digital interfaces |
RS232 Optional Profibus |
Ambient temperature | 5...40 °C |
Dimensions W x L x H (cm) | 36 x 61 x 47 |
Weight (kg) | 27 |
Classification according to DIN12876-1 | Classification III (FL) |
Description | Built-in cooling coil for tap water connection for temperature applications below or near ambient temperatures are integrated. |
Included with each unit | 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 male). |
Cooling coil | integrated |
Bath tank | Stainless steel |
Characteristics

Ample, easy to read VFD Comfort display for simultaneous display of 3 values, warning functions, high temperature cut-off, pump stages (resolution 0.01 °C)

Backlit indicator for selected pump stages and filling volume on Presto® PLUS, Magnum 91 & Forte HT

Comfortable keypad with additional menu functions for pump stages, calibration, control parameters, programmer, warnings, etc.

‘Intelligent Cascade Control’, automatic & self optimizing adjustment of PID control parameters, temperature stability ±0.005 °C internal, <±0.05 °C external

‘Temperature Control Features’ for individual optimization, access to all important control parameters, additional settings for band limit, limits, Co-Speedfactor etc.

‘Absolute Temperature Calibration’ for manual compensation of a temperature difference, 3-point calibration

Reliable and consistent pump capacity, electronically adjustable pump stages

External Pt100 sensor connection for precise measurement and control directly in the external application

RS232 interface for PC connection, e.g. for data communication and recording of measured values

Integrated programmer for the execution of time and temperature dependant profiles, 1 temperature profile with 10 steps max., with real time clock

Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down

Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function

Maximum safety, adjustable high temperature cut-off or dry-running protection, additional display of setpoints permits easy and precise adjustments

Classification III (FL) according to DIN 12876-1
Other characteristics
For temperature applications near or below ambient temperature: use a cooling coil or JULABO immersion cooler.
Technical changes without prior notification.
Images may deviate from the original.
We would be pleased to submit a non-binding offer for the selected product or answer all pertinent questions.