FPW50-HL Refrigerated/Heating Circulator
Superior models for most demanding applications
JULABO Refrigerated & Heating Circulators for heating and cooling are suitable for external temperature tasks and for temperature applications directly in the bath. A model from three different series’ with different capacities can be selected. Powerful circulating pump systems and high heating and cooling capacities guarantee short heat-up and cool-down times. The inevitable dust accumulation that occurs in refrigeration systems is solved by means of an easily removed venting grill, which allows for easy cleaning. Depending on the model, the units are equipped with handles or castors for an easy transportation. All models have a drain tap on the front allowing the fluid to be drained easily. The compact assembly of each unit enables a space to be saved in the laboratory.
Your advantages
- VFD COMFORT DISPLAY
- LCD DIALOG DISPLAY backlit for convenient interactive operation
- Keypad for setpoints, warning/safety values and menu functions
- ICC (Intelligent Cascade Control), self-optimizing temperature control
- TCF Temperature Control Features to optimize the control behaviour
- ATC3 3-Point-Calibration
- Pt100 External sensor connection for measurement and control
- SMART PUMP, electronically adjustable pump stages
- Druck- und Saugpumpe
- Early warning system for low liquid level (DBGM 203 06 059.8)
- Adjustable high temperature cut-out, visible via display
- RS232/RS485 interface for online communication
- Optional: Analog interface
- Integrated programmer for 6 x 60 program steps
- Connections for solenoid valve and HSP booster pump
- Active Cooling Control
- Proportional-Kälteleistungsregelung
Technical Data
| Order No. | 9312651 | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model series | HighTech | ||||||||||||
| Category | Refrigerated - Heating Circulators | ||||||||||||
| Working temperature range (°C) | -50 ... +200 | ||||||||||||
| Temperature control | ICC | ||||||||||||
| Temperature stability (°C) | ±0.01 | ||||||||||||
| Setting / display resolution | 0.01 °C | ||||||||||||
| Integrated programmer | 6x60 steps | ||||||||||||
| Temperature Display | VFD , LCD | ||||||||||||
| Heating capacity (kW) | 2 | ||||||||||||
| Cooling capacity (Medium Ethanol) |
|
||||||||||||
| Pump capacity flow rate (l/min) | 22-26 | ||||||||||||
| Pump capacity flow pressure (bar) | 0.4-0.7 | ||||||||||||
| Pump capacity flow suction (bar) | 0.2-0.4 | ||||||||||||
| Bath opening / bath depth (W x L / D cm) | 18 x 12 / 15 | ||||||||||||
| Pump connections | M16x1 | ||||||||||||
| Barbed fittings diameter (inner dia. / mm) | 8 / 12 | ||||||||||||
| Filling volume (liters) | 8 | ||||||||||||
| Refrigerant stage 1 | R404A | ||||||||||||
| Filling volume refrigerant stage 1 (g) | 480 | ||||||||||||
| Global Warming Potential for R404A | 3922 | ||||||||||||
| Carbon dioxide equivalent stage 1 (t) | 1.883 | ||||||||||||
| External Pt100 sensor connection | integrated | ||||||||||||
| Digital interfaces |
RS232 RS485 Optional Profibus |
||||||||||||
| Ambient temperature | 5...40 °C | ||||||||||||
| Dimensions W x L x H (cm) | 42 x 49 x 72 | ||||||||||||
| Weight (kg) | 57 | ||||||||||||
| Classification according to DIN12876-1 | Classification III (FL) | ||||||||||||
| Included with each unit | 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). | ||||||||||||
| Cooling of compressor | Water | ||||||||||||
| Power requirement V / Hz / A | 230/50/14 Additional voltage versions available |
Characteristics
Ample, easy to read VFD Comfort display for simultaneous display of 3 values, warning functions, high temperature cut-off, pump stages (resolution 0.01 °C)
Comfortable LCD dialog display for interactive operation with plain text display
Backlit indicator for selected pump stages and filling volume on Presto® PLUS, Magnum 91 & Forte HT
Comfortable keypad with additional menu functions for pump stages, calibration, control parameters, programmer, warnings, etc.
‘Intelligent Cascade Control’, automatic & self optimizing adjustment of PID control parameters, temperature stability ±0.005 °C internal, <±0.05 °C external
‘Temperature Control Features’ for individual optimization, access to all important control parameters, additional settings for band limit, limits, Co-Speedfactor etc.
‘Absolute Temperature Calibration’ for manual compensation of a temperature difference, 3-point calibration
Proportional cooling control for automatic adjustment of cooling power or temporary switch-off of compressor as needed to save up to 90 % energy in comparison to unregulated cooling machines
Easily removable venting grid for quick and easy cleaning
‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures
A heated cover plate prevents condensation or ice build-up in the bath
Reliable and consistent pump capacity, electronically adjustable pump stages
External Pt100 sensor connection for precise measurement and control directly in the external application
RS232/RS485 dual-interface for serial data transmission according to EIA-485 industry standard (2-wire bus technology), upgradable with Profibus DP
For the execution of time and temperature dependant profiles, 6 temperature profiles with 60 steps max., with real time clock
Stakei connections for solenoid valve, HSP booster pump and HST booster heater
Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down
Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function
Maximum safety, adjustable high temperature cut-off or dry-running protection, additional display of setpoints permits easy and precise adjustments
Classification III (FL) according to DIN 12876-1
Other characteristics
Optional: Electronic module with analog connections for external programming, temperature recorder, standby, alarm (Order no. 8 900 100).
Technical changes without prior notification.
Images may deviate from the original.
We would be pleased to submit a non-binding offer for the selected product or answer all pertinent questions.
click here for quotation request FPW50-HLSearch
Contact
JULABO GmbH
Gerhard-Juchheim-Strasse 1
77960 Seelbach / Germany
Tel: +49 7823 51-0
info.de@julabo.com
www.julabo.com
Contact form
Available voltage versions
Order No.: 9312651
230 V / 50 Hz
230 V / 60 Hz





