F32-HL Refrigerated / Heating Circulator
Top-of-the-line for challenging tasks
The top-of-the-line models with HL circulators offer professional technology and maximum functionality. The additional LCD dialog display interactively assists the user in setting circulator parameters. Intelligent Cascade Control (ICC) and Temperature Control Features (TCF) ensure optimal control behavior. HL circulators also have a Stakei connection.
Request a quoteOrder No. | 9 312 632 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -35 ... +200 °C | |||||||||||
Temperature stability | ±0.01 °C | |||||||||||
Heating capacity | 0.8 kW | |||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||
|
||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | |||||||||||
Usable bath opening (W x L / D) |
18 x 12 / 15 cm | |||||||||||
Filling volume | 5.5 ... 8 l | |||||||||||
Dimensions (W × L × H) |
31 x 42 x 66 cm |
Order No. | 9 312 632 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -35 ... +200 °C | |||||||||||
Temperature stability | ±0.01 °C | |||||||||||
Heating capacity | 0.8 kW | |||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||
|
||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | |||||||||||
Usable bath opening (W x L / D) |
18 x 12 / 15 cm | |||||||||||
Filling volume | 5.5 ... 8 l | |||||||||||
Dimensions (W × L × H) |
31 x 42 x 66 cm |
Order No. | 9 312 632 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -35 ... +200 °C | |||||||||||
Temperature stability | ±0.01 °C | |||||||||||
Heating capacity | 1 kW | |||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||
|
||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | |||||||||||
Usable bath opening (W x L / D) |
18 x 12 / 15 cm | |||||||||||
Filling volume | 5.5 ... 8 l | |||||||||||
Dimensions (W × L × H) |
31 x 42 x 66 cm |
Order No. | 9 312 632 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -35 ... +200 °C | |||||||||||
Temperature stability | ±0.01 °C | |||||||||||
Heating capacity | 2 kW | |||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||
|
||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | |||||||||||
Usable bath opening (W x L / D) |
18 x 12 / 15 cm | |||||||||||
Filling volume | 5.5 ... 8 l | |||||||||||
Dimensions (W × L × H) |
31 x 42 x 66 cm |
Order No. | 9 312 632 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -35 ... +200 °C | |||||||||||
Temperature stability | ±0.01 °C | |||||||||||
Heating capacity | 2 kW | |||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||
|
||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | |||||||||||
Usable bath opening (W x L / D) |
18 x 12 / 15 cm | |||||||||||
Filling volume | 5.5 ... 8 l | |||||||||||
Dimensions (W × L × H) |
31 x 42 x 66 cm |
Order No. | 9 312 632 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -35 ... +200 °C | |||||||||||
Temperature stability | ±0.01 °C | |||||||||||
Heating capacity | 2 kW | |||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||
|
||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | |||||||||||
Usable bath opening (W x L / D) |
18 x 12 / 15 cm | |||||||||||
Filling volume | 5.5 ... 8 l | |||||||||||
Dimensions (W × L × H) |
31 x 42 x 66 cm |
Order No. | 9 312 632 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -35 ... +200 °C | |||||||||||
Temperature stability | ±0.01 °C | |||||||||||
Heating capacity | 2 kW | |||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||
|
||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | |||||||||||
Usable bath opening (W x L / D) |
18 x 12 / 15 cm | |||||||||||
Filling volume | 5.5 ... 8 l | |||||||||||
Dimensions (W × L × H) |
31 x 42 x 66 cm |
Order No. | 9 312 632 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -35 ... +200 °C | |||||||||||
Temperature stability | ±0.01 °C | |||||||||||
Heating capacity | 2 kW | |||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||
|
||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | |||||||||||
Usable bath opening (W x L / D) |
18 x 12 / 15 cm | |||||||||||
Filling volume | 5.5 ... 8 l | |||||||||||
Dimensions (W × L × H) |
31 x 42 x 66 cm |
Order No. | 9 312 632 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -35 ... +200 °C | |||||||||||
Temperature stability | ±0.01 °C | |||||||||||
Heating capacity | 2 kW | |||||||||||
Cooling capacity |
|
|
||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||
|
||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | |||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | |||||||||||
Usable bath opening (W x L / D) |
18 x 12 / 15 cm | |||||||||||
Filling volume | 5.5 ... 8 l | |||||||||||
Dimensions (W × L × H) |
31 x 42 x 66 cm |
Product Features
- VFD COMFORT DISPLAY
- LCD DIALOG DISPLAY backlit for convenient interactive operation
- Keypad for setpoints, warning/safety values and menu functions
- ICC (Intelligent Cascade Control), self-optimizing temperature control
- TCF Temperature Control Features to optimize the control behavior
- ATC3 3-Point-Calibration
- Pt100 External sensor connection for measurement and control
- SMART PUMP, electronically adjustable pump stages
- Adjustable pressure and suction pump
- Adjustable high temperature cut-out, visible via display
- RS232/RS485 interface for online communication
- Optional: analogue interfaces
- Integrated programmer for 6 x 60 program steps
- Connections for solenoid valve and HSP booster pump
- Active Cooling Control
Dimensions (W × L × H) |
31 x 42 x 66 cm |
---|---|
Filling volume | 5.5 ... 8 l |
Weight | 38 kg |
Pump connections | M16x1 male |
Barbed fittings inner diameter | 8/12 mm |
Working temperature range | -35 ... +200 °C |
---|---|
Temperature stability | ±0.01 °C |
Setting the resolution of the temperature display | 0.01 °C |
Temperature display resolution | 0.01 °C |
Ambient temperature | +5.0 ... +40.0 °C |
Heating capacity | 0.8 kW | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||
|
|||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | ||||||||||||
Maximum suction | 0.2 ... 0.4 bar | ||||||||||||
Viscosity max. | 70 cST | ||||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||||
Global Warming Potential for R134a | 1430 | ||||||||||||
Filling volume | 166 g | ||||||||||||
Carbon dioxide equivalent | 0.237 t | ||||||||||||
Power | 14 A |
Heating capacity | 0.8 kW | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||
|
|||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | ||||||||||||
Maximum suction | 0.2 ... 0.4 bar | ||||||||||||
Viscosity max. | 70 cST | ||||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||||
Global Warming Potential for R134a | 1430 | ||||||||||||
Filling volume | 166 g | ||||||||||||
Carbon dioxide equivalent | 0.237 t | ||||||||||||
Power | 14 A |
Heating capacity | 1 kW | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||
|
|||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | ||||||||||||
Maximum suction | 0.2 ... 0.4 bar | ||||||||||||
Viscosity max. | 70 cST | ||||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||||
Global Warming Potential for R134a | 1430 | ||||||||||||
Filling volume | 166 g | ||||||||||||
Carbon dioxide equivalent | 0.237 t | ||||||||||||
Power | 14 A |
Heating capacity | 2 kW | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||
|
|||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | ||||||||||||
Maximum suction | 0.2 ... 0.4 bar | ||||||||||||
Viscosity max. | 70 cST | ||||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||||
Global Warming Potential for R134a | 1430 | ||||||||||||
Filling volume | 166 g | ||||||||||||
Carbon dioxide equivalent | 0.237 t | ||||||||||||
Power | 12 A |
Heating capacity | 2 kW | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||
|
|||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | ||||||||||||
Maximum suction | 0.2 ... 0.4 bar | ||||||||||||
Viscosity max. | 70 cST | ||||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||||
Global Warming Potential for R134a | 1430 | ||||||||||||
Filling volume | 166 g | ||||||||||||
Carbon dioxide equivalent | 0.237 t | ||||||||||||
Power | 12 A |
Heating capacity | 2 kW | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||
|
|||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | ||||||||||||
Maximum suction | 0.2 ... 0.4 bar | ||||||||||||
Viscosity max. | 70 cST | ||||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||||
Global Warming Potential for R134a | 1430 | ||||||||||||
Filling volume | 166 g | ||||||||||||
Carbon dioxide equivalent | 0.237 t | ||||||||||||
Power | 2 A |
Heating capacity | 2 kW | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||
|
|||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | ||||||||||||
Maximum suction | 0.2 ... 0.4 bar | ||||||||||||
Viscosity max. | 70 cST | ||||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||||
Global Warming Potential for R134a | 1430 | ||||||||||||
Filling volume | 166 g | ||||||||||||
Carbon dioxide equivalent | 0.237 t | ||||||||||||
Power | 2 A |
Heating capacity | 2 kW | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||
|
|||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | ||||||||||||
Maximum suction | 0.2 ... 0.4 bar | ||||||||||||
Viscosity max. | 70 cST | ||||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||||
Global Warming Potential for R134a | 1430 | ||||||||||||
Filling volume | 166 g | ||||||||||||
Carbon dioxide equivalent | 0.237 t | ||||||||||||
Power | 12 A |
Heating capacity | 2 kW | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity |
|
|
|||||||||||
Cooling capacity
(Medium: Ethanol) |
|||||||||||||
|
|||||||||||||
Pump capacity flow rate | 22 ... 26 l/min | ||||||||||||
Pump capacity flow pressure | 0.4 ... 0.7 bar | ||||||||||||
Maximum suction | 0.2 ... 0.4 bar | ||||||||||||
Viscosity max. | 70 cST | ||||||||||||
Refrigerant stage 1 |
Refrigerant | R134a | |||||||||||
Global Warming Potential for R134a | 1430 | ||||||||||||
Filling volume | 166 g | ||||||||||||
Carbon dioxide equivalent | 0.237 t | ||||||||||||
Power | 12 A |
Bath cover | integrated |
---|---|
Usable bath opening (W x L / D) |
18 x 12 / 15 cm |
Cooling of compressor | 1-stage Air |
---|
Sound pressure level | 53 dbA |
---|---|
Classification according to DIN12876-1 |
Classification III (FL) |
IP Code according to IEC 60529 |
IP 21 |
Pump type | Immersion Pump |
Digital interface | Profibus optional |
---|---|
External pt100 sensor connection | integrated |
Integrated programmer | 6x60 steps |
Temperature control | ICC |
Absolute temperature calibration | 3 Point Calibration |
Temperature display | VFD |
Temperature setting | Keypad |
100V/50-60Hz Nema N5-15 Plug | 9312632.01 |
---|---|
115V/60Hz Nema N5-15 Plug | 9312632.02 |
230V/50-60Hz UK Plug Type BS1363A | 9312632.04 |
230V/50-60Hz CH Plug Type SEV 1011 | 9312632.05 |
230V/50-60Hz Schuko Plug - CEE 7/4 Plug Type F | 9312632.33 |
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for F32-HL
Benefits
-
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory. -
Green technology.
Development consistently applied environmentally friendly materials and technologies. -
Intelligent temperature control.
Intelligent cascade control - automatic and self-optimizing adaptation of the PID control parameters with external stability of +/- 0.05 °C. -
JULABO. Quality.
Highest standards of quality for a long product life.