CORIO CD-300F Refrigerated – Heating Circulator

The new generation of laboratory circulators for routine work and standard tasks

Refrigerated / Heating Circulators of the new CORIO series distinguish themselves with a great price-to-performance ratio. They are ideal for all standard tasks and routine work in laboratories and industry.

Request a quote
Data based on voltage version:
230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F)
CD-300F
Order No. 9 012 703.01
Working temperature range -25 ... +150 °C
Temperature stability ±0.03 °C
Heating capacity 0.8 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -10 -20
0.31 0.28 0.2 0.11
Cooling capacity
(Medium: Ethanol)
°C 20 0 -10 -20
kW 0.31 0.28 0.2 0.11
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.27 bar
Usable bath opening
(W x L / D)
13 x 15 / 15 cm
Filling volume 3 ... 4 l
Dimensions
(W × L × H)
24 x 42 x 66 cm
CD-300F
Order No. 9 012 703.01
Working temperature range -25 ... +150 °C
Temperature stability ±0.03 °C
Heating capacity 0.8 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -10 -20
0.31 0.28 0.2 0.11
Cooling capacity
(Medium: Ethanol)
°C 20 0 -10 -20
kW 0.31 0.28 0.2 0.11
Pump capacity flow rate 16 l/min
Pump capacity flow pressure 0.35 bar
Usable bath opening
(W x L / D)
13 x 15 / 15 cm
Filling volume 3 ... 4 l
Dimensions
(W × L × H)
24 x 42 x 66 cm
CD-300F
Order No. 9 012 703.02
Working temperature range -25 ... +150 °C
Temperature stability ±0.03 °C
Heating capacity 1 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -10 -20
0.31 0.28 0.2 0.11
Cooling capacity
(Medium: Ethanol)
°C 20 0 -10 -20
kW 0.31 0.28 0.2 0.11
Pump capacity flow rate 16 l/min
Pump capacity flow pressure 0.33 bar
Usable bath opening
(W x L / D)
13 x 15 / 15 cm
Filling volume 3 ... 4 l
Dimensions
(W × L × H)
24 x 42 x 66 cm
CD-300F
Order No. 9 012 703.03
Working temperature range -25 ... +150 °C
Temperature stability ±0.03 °C
Heating capacity 2 kW
Cooling capacity
°C
kW
20 0 -10 -20
0.31 0.28 0.2 0.11
Cooling capacity
(Medium: Ethanol)
°C 20 0 -10 -20
kW 0.31 0.28 0.2 0.11
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.35 bar
Usable bath opening
(W x L / D)
13 x 15 / 15 cm
Filling volume 3 ... 4 l
Dimensions
(W × L × H)
24 x 42 x 66 cm
CD-300F
Order No. 9 012 703.03.chn
Working temperature range -25 ... +150 °C
Temperature stability ±0.03 °C
Heating capacity 2 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -10 -20
0.31 0.28 0.2 0.11
Cooling capacity
(Medium: Ethanol)
°C 20 0 -10 -20
kW 0.31 0.28 0.2 0.11
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.35 bar
Usable bath opening
(W x L / D)
13 x 15 / 15 cm
Filling volume 3 ... 4 l
Dimensions
(W × L × H)
24 x 42 x 66 cm
CD-300F
Order No. 9 012 703.04
Working temperature range -25 ... +150 °C
Temperature stability ±0.03 °C
Heating capacity 2 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -10 -20
0.31 0.28 0.2 0.11
Cooling capacity
(Medium: Ethanol)
°C 20 0 -10 -20
kW 0.31 0.28 0.2 0.11
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.35 bar
Usable bath opening
(W x L / D)
13 x 15 / 15 cm
Filling volume 3 ... 4 l
Dimensions
(W × L × H)
24 x 42 x 66 cm
CD-300F
Order No. 9 012 703.05
Working temperature range -25 ... +150 °C
Temperature stability ±0.03 °C
Heating capacity 2 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -10 -20
0.31 0.28 0.2 0.11
Cooling capacity
(Medium: Ethanol)
°C 20 0 -10 -20
kW 0.31 0.28 0.2 0.11
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.35 bar
Usable bath opening
(W x L / D)
13 x 15 / 15 cm
Filling volume 3 ... 4 l
Dimensions
(W × L × H)
24 x 42 x 66 cm
CD-300F
Order No. 9 012 703.13
Working temperature range -25 ... +150 °C
Temperature stability ±0.03 °C
Heating capacity 2 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -10 -20
0.31 0.28 0.2 0.11
Cooling capacity
(Medium: Ethanol)
°C 20 0 -10 -20
kW 0.31 0.28 0.2 0.11
Pump capacity flow rate 17 l/min
Pump capacity flow pressure 0.43 bar
Usable bath opening
(W x L / D)
13 x 15 / 15 cm
Filling volume 3 ... 4 l
Dimensions
(W × L × H)
24 x 42 x 66 cm

Product Features

  • Models for internal and external applications
  • Very quiet
  • Bright, white, easy to read display
  • Easy pump change-over between internal and external circulation
  • USB connection
  • External pump connections
  • Class III (FL) according to DIN 12876-1
  • Space-saving cooling coil design yields more usable space in the bath tank
  • High-quality bath tanks made of stainless steel with bath lid and drain tap
  • Bath lid and drain tap included
  • Removable ventilation grid
  • Refrigeration unit without side vents
Dimensions and volumes
Dimensions
(W × L × H)
24 x 42 x 66 cm
Filling volume 3 ... 4 l
Weight 28 kg
Pump connections M16x1  male
Barbed fittings inner diameter 8/12 mm
Temperature values
Working temperature range -25 ... +150 °C
Temperature stability ±0.03 °C
Setting the resolution of the temperature display 0.1 °C
Temperature display resolution 0.01 ... 0.1 °C
Ambient temperature +5 ... +40 °C
Data based on voltage version:
230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F)
Performance values
Heating capacity 0.8 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -10 -20
0.31 0.28 0.2 0.11
Cooling capacity
(Medium: Ethanol)
°C 20 0 -10 -20
kW 0.31 0.28 0.2 0.11
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.27 bar
Viscosity max. 50 cST
Refrigerant stage 1
Refrigerant R134a
Global Warming Potential for R134a 1430
Filling volume 100 g
Carbon dioxide equivalent 0.143 t
Performance values
Heating capacity 0.8 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -10 -20
0.31 0.28 0.2 0.11
Cooling capacity
(Medium: Ethanol)
°C 20 0 -10 -20
kW 0.31 0.28 0.2 0.11
Pump capacity flow rate 16 l/min
Pump capacity flow pressure 0.35 bar
Viscosity max. 50 cST
Refrigerant stage 1
Refrigerant R134a
Global Warming Potential for R134a 1430
Filling volume 100 g
Carbon dioxide equivalent 0.143 t
Performance values
Heating capacity 1 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -10 -20
0.31 0.28 0.2 0.11
Cooling capacity
(Medium: Ethanol)
°C 20 0 -10 -20
kW 0.31 0.28 0.2 0.11
Pump capacity flow rate 16 l/min
Pump capacity flow pressure 0.33 bar
Viscosity max. 50 cST
Refrigerant stage 1
Refrigerant R134a
Global Warming Potential for R134a 1430
Filling volume 100 g
Carbon dioxide equivalent 0.143 t
Performance values
Heating capacity 2 kW
Cooling capacity
°C
kW
20 0 -10 -20
0.31 0.28 0.2 0.11
Cooling capacity
(Medium: Ethanol)
°C 20 0 -10 -20
kW 0.31 0.28 0.2 0.11
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.35 bar
Viscosity max. 50 cST
Refrigerant stage 1
Refrigerant R134a
Global Warming Potential for R134a 1430
Filling volume 100 g
Carbon dioxide equivalent 0.143 t
Performance values
Heating capacity 2 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -10 -20
0.31 0.28 0.2 0.11
Cooling capacity
(Medium: Ethanol)
°C 20 0 -10 -20
kW 0.31 0.28 0.2 0.11
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.35 bar
Viscosity max. 50 cST
Refrigerant stage 1
Refrigerant R134a
Global Warming Potential for R134a 1430
Filling volume 100 g
Carbon dioxide equivalent 0.143 t
Performance values
Heating capacity 2 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -10 -20
0.31 0.28 0.2 0.11
Cooling capacity
(Medium: Ethanol)
°C 20 0 -10 -20
kW 0.31 0.28 0.2 0.11
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.35 bar
Viscosity max. 50 cST
Refrigerant stage 1
Refrigerant R134a
Global Warming Potential for R134a 1430
Filling volume 100 g
Carbon dioxide equivalent 0.143 t
Performance values
Heating capacity 2 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -10 -20
0.31 0.28 0.2 0.11
Cooling capacity
(Medium: Ethanol)
°C 20 0 -10 -20
kW 0.31 0.28 0.2 0.11
Pump capacity flow rate 15 l/min
Pump capacity flow pressure 0.35 bar
Viscosity max. 50 cST
Refrigerant stage 1
Refrigerant R134a
Global Warming Potential for R134a 1430
Filling volume 100 g
Carbon dioxide equivalent 0.143 t
Performance values
Heating capacity 2 kW
Cooling capacity
(Medium: Ethanol)
°C
kW
20 0 -10 -20
0.31 0.28 0.2 0.11
Cooling capacity
(Medium: Ethanol)
°C 20 0 -10 -20
kW 0.31 0.28 0.2 0.11
Pump capacity flow rate 17 l/min
Pump capacity flow pressure 0.43 bar
Viscosity max. 50 cST
Refrigerant stage 1
Refrigerant R134a
Global Warming Potential for R134a 1430
Filling volume 100 g
Carbon dioxide equivalent 0.143 t
Bath
Bath tank Stainless steel
Bath cover integrated
Usable bath opening
(W x L / D)
13 x 15 / 15 cm
Cooling
Cooling of compressor 1-stage Air
Other
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Pump function Pressure Pump
Pump type Immersion Pump
Electronics
Temperature control PID1
Absolute temperature calibration 1 Point Calibration
Temperature display LED
Temperature setting Keypad
Available voltage versions
100V/50-60Hz Nema N5-15 Plug 9012703.01
115V/60Hz Nema N5-15 Plug 9012703.02
230V/50Hz Schuko Plug - CEE 7/4 Plug Type F 9012703.03
230V/50Hz CN Plug 9012703.03.chn
230V/50Hz UK Plug Type BS1363A 9012703.04
230V/50Hz CH Plug Type SEV 1011 9012703.05
230V/60Hz Schuko Plug - CEE 7/4 Plug Type F 9012703.13
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)
chart_hu_corio-cd-300F_thermal
chart_cd_corio-cd-300F_thermal
chart_cd_corio-cd-300F_ethanol

Accessory for CORIO CD-300F

Brochure

CORIO Brochure
English
PDF - 6.77 MB

Download

Operation Manual

19510800-V9
English
PDF - 6.44 MB

Download

Product Data Sheet

CORIO CD-300F
English
PDF - 462.12 KB

Download

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

Benefits

  • 100% geprüft
    100% Checked.
    100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
  • ATC.ai
    ATC.
    Absolute Temperature Calibration, 1-point calibration (CD).
  • easy-to-handle.psd
    Handle with ease.
    Makes day-to-day work easy. Comfortably move your JULABO Circulator around by using the ergonomic handles (front and rear).
  • more-bath.psd
    More bath.
    Designed for more comfort. Thanks to the recessed cooling coil, the internal bath provides more space.
  • space-saving.psd
    Space saving. Free up space.
    Place your JULABO Circulator right next to an application, another unit, or wall. That saves space. This is made possible by eliminating vents and connections on the sides.
  • condensation-protection_CORIO
    Condensation protection.
    Superb design solution. Integrated ventilation directs air over the bath lid and minimizes condensation.
  • Blatt wächst in einer Glühbirne
    Green technology.
    Development consistently applied environmentally friendly materials and technologies.
  • easy-pump-control.psd
    Internal. External.
    The pump is controlled via a lever located directly below the display. Easily change between internal and external circulation.
  •  -- en
    Modern. Reliable.
    High-grade components in every JULABO Circulator – platinum sensors, proven motor technology, CAN-Bus communication and much more.
  • Safety.
    CORIO CD and CP comply with Class III (FL) according to DIN 12876-1 and switches off automatically in case of high temperature or low liquid level alarm.
  • network
    Satisfied customers.
    11 subsidiaries and more than 100 partners worldwide guarantee fast and qualified JULABO support.
  • Downloads
    Services 24/7.
    Around the clock availability. You can find suitable accessories, data sheets, manuals, case studies, and more at www.julabo.com.
  • Solid.psd
    Solid.
    Minimized energy loss through high-quality insulation.
  •  -- en
    Stable.
    Rubber feet allow for a secured footing of your CORIO to prevent damage to your laboratory equipment.
  •  -- en
    Tidy.
    The special drain tap for easy draining of bath fluids without tools.
  • insulation.psd
    Touching permitted.
    Optimum safety. The ergonomic plastic handle protects your fingers from hot surfaces.
  • Made in Germany
    JULABO. Quality.
    Highest standards of quality for a long product life.
  • Quickstart
    Quick start.
    Individual JULABO consultation and comprehensive manuals at your disposal.
  • timer-function.psd
    Timer. Integrated.
    CORIO circulators include an integrated timer function. When the set time has elapsed, a signal sounds and the device switches off. Setting range: 0 ... 999 minutes.
  • brilliant-display.psd
    Brilliant.
    Very bright display makes it easy to read even from a distance.
  • easy-conectivity.psd
    Connection. Easy.
    Inclined pump connections (M16×1) facilitate the connection of applications. Each unit includes 2 barbed fittings of 8/12 mm diameter each.
  • all-in-front.psd
    Everything at the front.
    All operating controls and safety functions are accessed easily and comfortably from the front.
  • ACCUND_PID1.ai
    Exact.
    You can rely on it. PID1 control and 'Active Cooling Control' make the new CORIO precise and perfect.
  • profesional-plug-connection.psd
    Locked in.
    The lockable power plug guarantees safe connection. More process safety.
  • switch-on-start.psd
    Switch on. And off you go.
    Intelligent operating concept. Ready for operation with just a few quick and easy steps.
  • EarlyWarningSystemLowLiquid.ai
    Early warning system for low liquid level
    Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down
  • usb-connectivity.psd
    Connectivity.
    Remote control made easy. CORIO CD circulators feature a USB connection.