Print

FL1703 Recirculating Cooler

Recirculating Cooler/Chiller for environmentally friendly cooling

The FL series offers a new generation of chillers for routine cooling applications within the laboratory and industry. The temperature stability of the PID control is ±0.5°C. All units can easily be cleaned and are provided with a splash water proof keypad with LED temperature indication. On the front of the units there is an RS232 interface as well as an alarm shutdown. The filling port is easily accessible placed on the top under a lift-up cover. Another hinged tray serves as a file for the operating manual or other documents concerning the installation. The removable venting grid allows an easy cleaning of the condenser, the drain tap is easily accessible behind the grid. All models include an easily visible level indication. Another advantage is the venting slots are on the front and rear and therefore the units can be placed directly one beside the other (space saving).  

Your advantages

  • Ergonomic design and easy operation
  • Splash-proof keypad
  • Large, bright LED display
  • Reliable Microprocessor PID temperature control
  • Filling level indicator
  • Powerful immersion pumps, suitable for continuous operation
  • Permissible temperature in return line +80°C
  • Easy filling from the top with hinged protective lid
  • Low liquid level protection with optical and audible alarm signal
  • Integrated stainless steel bath tanks
  • Removable venting grid for cleaning of the condenser
  • Front drain
  • No side vents
  • RS232 interface for PC-connection
  • IP class according to IEC 60529: 21
  • Alarm output, potential-free change-over contact (max. 30 VA)
  • Pressure Indicator
  • By-pass valve to adjust pump pressure

Technical Data

Order No. 9663017
Model series FL Series
Category Recirculating Coolers
Working temperature range (°C) -20 ... +40
Temperature stability (°C) ±0.5
Setting / display resolution 0.1 °C
Temperature Display LED
Cooling capacity (Medium Ethanol)
°C20100-10-20
kW1.71.410.750.3
Pump capacity flow rate (l/min) 40
Pump capacity flow pressure (bar) 0.5-3.0
Pump connections G3/4"
Barbed fittings diameter (inner dia. / mm) 3/4"
Filling volume (liters) 12 ... 17
Refrigerant stage 1 R452A
Filling volume refrigerant stage 1 (g) 690
Global Warming Potential for R452A 2140
Carbon dioxide equivalent stage 1 (t) 1.477
Digital interfaces RS232
Optional Profibus
Ambient temperature 5...40 °C
Dimensions W x L x H (cm) 50 x 76 x 64
Weight (kg) 91
Description Suitable fluids: water, water-glycol mixture, JULABO Thermal bath fluids
Included with each unit 2 barbed fittings for tubing 3/4" inner dia. (pump connections G3/4" male)
Cooling of compressor Air
Refrigerant specifications are valid for the 50 Hz version.

Characteristics

Display 
Easy to read
Easy to read
Large LED temperature display for actual value and setpoint (resolution 0.1 °C)
Operation 
Simple and fast 
Simple and fast 
Convenient 3-key setpoint adjustment (FL models)
Temperature Control
Precise
Precise
PID Temperature control with set control parameters, temperature stability ±0.02...±0.2 °C
Refrigeration Technology
Consistent cooling capacity
Consistent cooling capacity
Easily removable venting grid for quick and easy cleaning
Technical Features
Serial connection
Serial connection
RS232 interface for PC connection, e.g. for data communication and recording of measured values

Technical changes without prior notification.
Images may deviate from the original.

We would be pleased to submit a non-binding offer for the selected product or answer all pertinent questions.

click here for quotation request FL1703
 

Contact

JULABO GmbH
Gerhard-Juchheim-Strasse 1
77960 Seelbach / Germany
Tel: +49 7823 51-0
info.de@julabo.com
www.julabo.com
Contact form

Available voltage versions

Model: FL1703
Order No.: 9663017
230 V / 50 Hz
230 V / 60 Hz
Catalog request
Order our brochures!