Print

Refrigerated - Heating Circulators

for working temperatures from -50 °C to +200 °C

JULABO Refrigerated and Heating Circulators are suitable for temperature application to external systems with simultaneous operation in the bath tank. Models in different performance classes are available. The units provide high heating/cooling capacities to ensure rapid heat-up and cool-down times. With ‚Active Cooling Control' to +200 °C. ‚FP‘ models offer proportional cooling control to ensure energy-saving performance and to reduce heat generation to the environment. Convenient cleaning of dust by removable venting grid. Some models have a handle or castors to allow easy transport. All models provide a drain port on the front for conveniently draining the bath fluid. Typical applications: Temperature applications to external, closed systems, such as for example photometers, refractometers, viscometers, etc. For simultaneous application to small objects in the circulator bath.

Product overview


CORIO new
Order No. Model Working temperature
range (°C)
Temperature stability
(°C)
Cooling capacity at 20 °C Heating capacity (kW) Pump capacity flow rate (l/min) Pump pressure (psi) Comparison
9012701 CORIO CD-200F -20 ... +150 ±0.03 0.22 1 15 5.08
9012702 CORIO CD-201F -20 ... +150 ±0.03 0.22 1 15 5.08
9012703 CORIO CD-300F -25 ... +150 ±0.03 0.31 1 15 5.08
9012704 CORIO CD-600F -35 ... +150 ±0.03 0.6 1 15 5.08
9012705 CORIO CD-601F -40 ... +150 ±0.03 0.6 1 15 4.8
9012706 CORIO CD-900F -40 ... +150 ±0.03 0.9 1 15 4.8
9012707 CORIO CD-1000F -40 ... +150 ±0.03 1 1 15 5.08
9012708 CORIO CD-1001F -38 ... +100 ±0.03 1 1.5 15
9013701 CORIO CP-200F -20 ... +200 ±0.03 0.2 1 8 ... 27 1.5 ... 10.2
9013702 CORIO CP-201F -20 ... +200 ±0.03 0.2 1 8 ... 27 1.5 ... 10.2
9013703 CORIO CP-300F -25 ... +200 ±0.03 0.3 1 8 ... 27 1.5 ... 10.2
9013704 CORIO CP-600F -35 ... +200 ±0.03 0.6 1 8 ... 27 1.5 ... 10.2
9013705 CORIO CP-601F -35 ... +200 ±0.03 0.6 1 8 ... 27 1.5 ... 10.2
9013706 CORIO CP-900F -38 ... +200 ±0.03 0.9 1 8 ... 27 1.5 ... 10.2
9013707 CORIO CP-1000F -50 ... +200 ±0.03 1 1 8 ... 27 1.5 ... 10.2
9013708 CORIO CP-1001F -38 ... +100 ±0.03 1 1 8 ... 27 1.5 ... 10.2

DYNEO new
Order No. Model Working temperature
range (°C)
Temperature stability
(°C)
Cooling capacity at 20 °C Heating capacity (kW) Pump capacity flow rate (l/min) Pump pressure (psi) Comparison
9021701 DYNEO DD-200F -20 ... +200 ±0.01 0.2 1 8 ... 23 1.5 ... 8.7
9021702 DYNEO DD-201F -20 ... +200 ±0.01 0.2 1 8 ... 23 1.5 ... 8.7
9021703 DYNEO DD-300F -25 ... +200 ±0.01 0.3 1 8 ... 23 1.5 ... 8.7
9021704 DYNEO DD-600F -35 ... +200 ±0.01 0.6 1 8 ... 23 1.5 ... 8.7
9021705 DYNEO DD-601F -35 ... +200 ±0.01 0.6 1 8 ... 23 1.5 ... 8.7
9021706 DYNEO DD-900F -38 ... +200 ±0.01 0.9 1 8 ... 23 1.5 ... 8.7
9021707 DYNEO DD-1000F -50 ... +200 ±0.01 1 1 8 ... 23 1.5 ... 8.7
9021708 DYNEO DD-1001F -38 ... +100 ±0.01 1 1 8 ... 23 1.5 ... 8.7

HighTech
Order No. Model Working temperature
range (°C)
Temperature stability
(°C)
Cooling capacity at 20 °C Heating capacity (kW) Pump capacity flow rate (l/min) Pump pressure (psi) Comparison
9212625 F25-HE -28 ... +200 ±0.01 0.26 1 22-26 5.8-10.2
9212632 F32-HE -35 ... +200 ±0.01 0.45 1 22-26 5.8-10.2
9212634 F34-HE -30 ... +150 ±0.01 0.45 1 22-26 5.8-10.2
9212650 FP50-HE -50 ... +200 ±0.01 0.9 2 22-26 5.8-10.2
9212651 FPW50-HE -50 ... +200 ±0.01 0.9 1 22-26 5.8-10.2
9312618 FP35-HL -35 ... +150 ±0.01 0.45 1 22-26 5.8-10.2
9312625 F25-HL -28 ... +200 ±0.01 0.26 1 22-26 5.8-10.2
9312632 F32-HL -35 ... +200 ±0.01 0.45 1 22-26 5.8-10.2
9312633 F33-HL -30 ... +200 ±0.01 0.5 1 22-26 5.8-10.2
9312650 FP50-HL -50 ... +200 ±0.01 0.9 2 22-26 5.8-10.2
9312651 FPW50-HL -50 ... +200 ±0.01 0.9 1 22-26 5.8-10.2