Heating Circulators
with high-quality insulated bath tanks for temperature applications up to +300 °C
JULABO circulators with stainless steel bath tanks are suitable for both internal and external temperature control. They have greater power for larger and open systems, making them ideal for external temperature control. Smaller objects may be inserted directly into the circulator's bath at the same time. Models are available with a variety of bath sizes and other functional characteristics. Accessories like Pt100 sensors, heat transfer liquid, tubing, and adapters are available to facilitate connection to external systems. An integrated cooling coil enables temperature control below or near the ambient temperature.
Models are available with a variety of bath sizes and other functional characteristics. Accessories like Pt100 sensors, heat transfer liquid, tubing, and adapters are available to facilitate connection to external systems. An integrated cooling coil enables temperature control below or near the ambient temperature.
Product Features
- All products feature user-friendly, intuitive operation
- State-of-the-art control technology for quick and highly precise results
- Working temperatures from +20 °C to +300 °C
- Very quiet
- Easy operation
Product Overview
CORIO CD heating circulators
for internal and external temperature tasks with insulated stainless steel bath tanks and working temperatures from +20 °C to +150 °C
for internal and external temperature applications with stainless steel bath tanks and working temperatures from +20 °C to +150 °C
| Model | Add to compare CORIO CD-BC4 |
Add to compare CORIO CD-BC6 |
Add to compare CORIO CD-BC12 |
Add to compare CORIO CD-BC26 |
|---|---|---|---|---|
| Working temperature range (°C) | +20 ... +150 | +20 ... +150 | +20 ... +150 | +20 ... +150 |
| Temperature stability (°C) | ±0.03 | ±0.03 | ±0.03 | ±0.03 |
| Heating capacity (kW) | 2 | 2 | 2 | 2 |
| Pump capacity flow pressure (l/min) | 17 | 17 | 15 | 17 |
| Pump capacity pressure (psi) | 6.2 | 6.2 | 5.1 | 6.2 |
CORIO CP heating circulators
Laboratory circulators with an expanded working temperature range up to +200 °C
CORIO circulators offer professional technology for high demands. With these devices, temperature control is optionally possible in the internal bath or in a connected external application.
| Model | Add to compare CORIO CP-BC4 |
Add to compare CORIO CP-BC6 |
Add to compare CORIO CP-BC12 |
Add to compare CORIO CP-BC26 |
|---|---|---|---|---|
| Working temperature range (°C) | +20 ... +200 | +20 ... +200 | +20 ... +200 | +20 ... +200 |
| Temperature stability (°C) | ±0.02 | ±0.02 | ±0.02 | ±0.02 |
| Heating capacity (kW) | 2 | 2 | 2 | 2 |
| Pump capacity flow pressure (l/min) | 8 ... 27 | 8 ... 27 | 8 ... 27 | 8 ... 27 |
| Pump capacity pressure (psi) | 1.5 ... 10.2 | 1.5 ... 10.2 | 1.5 ... 10.2 | 1.5 ... 10.2 |
DYNEO DD heating circulators
for working temperatures from +20 °C to +200 °C
DYNEO DD heating circulators for internal and external applications are equipped with closed bath tanks. The tanks are well insulated and include a coil for counter-cooling. An integrated drain tap makes emptying the tank safe and clean. The multilingual 3.5-inch color display and unique rotary knob provide for straightforward and intuitive operation.
| Model | Add to compare DYNEO DD-BC4 |
Add to compare DYNEO DD-BC6 |
Add to compare DYNEO DD-BC12 |
Add to compare DYNEO DD-BC26 |
|---|---|---|---|---|
| Working temperature range (°C) | +20 ... +200 | +20 ... +200 | +20 ... +200 | +20 ... +200 |
| Temperature stability (°C) | ±0.01 | ±0.01 | ±0.01 | ±0.01 |
| Heating capacity (kW) | 2 | 2 | 2 | 2 |
| Pump capacity flow pressure (l/min) | 8 ... 27 | 8 ... 27 | 8 ... 27 | 8 ... 27 |
| Pump capacity pressure (psi) | 1.5 ... 10.2 | 1.5 ... 10.2 | 1.5 ... 10.2 | 1.5 ... 10.2 |
MAGIO MS / MX heating circulators
with extremely powerful pumps, intuitive touchscreen displays
Like all circulators in the MAGIO range, the heating circulators are characterised by premium quality and high performance combined with intuitive usability. The devices offer extra powerful pressure and suction pumps to meet the most challenging demands for temperature control of external applications. Samples can also be temperature controlled in the internal bath of the high-quality, insulated and closed bath tank.
| Model | Add to compare MAGIO MS-BC4 |
Add to compare MAGIO MX-BC6 |
Add to compare MAGIO MX-BC12 |
Add to compare MAGIO MX-BC26 |
|---|---|---|---|---|
| Working temperature range (°C) | +20 ... +300 | +20 ... +300 | +20 ... +300 | +20 ... +300 |
| Temperature stability (°C) | ±0.01 | ±0.01 | ±0.01 | ±0.01 |
| Heating capacity (kW) | 2 | 3 | 3 | 3 |
| Pump capacity flow pressure (l/min) | 16 ... 31 | 16 ... 31 | 16 ... 31 | 16 ... 31 |
| Pump capacity pressure (psi) | 3.5 ... 13.3 | 3.5 ... 13.3 | 3.5 ... 13.3 | 3.5 ... 13.3 |