CORIO Laboratory Circulators

Circulators are an important part of daily work in many laboratories of research institutions and industrial companies worldwide. The JULABO CORIO circulators have been developed with pioneering technologies for these laboratories and are manufactured to the highest quality standards in Germany.

CORIO Circulators - an overview of the categories

CORIO CD refrigerated / heating circulators

The new generation of laboratory circulators for routine work and standard tasks

Refrigerated / heating circulators of the CORIO CD series distinguish themselves with a great price-to-performance ratio. Durable and dependable, they are suitable for a wide range of standard and routine work in both laboratories and industrial environments.

Model
Add to compare
CORIO CD-200F
Add to compare
CORIO CD-201F
Add to compare
CORIO CD-310F
Add to compare
CORIO CD-449F
Working temperature range (°C) -20 ... 150 -20 ... 150 -30 ... 150 -32 ... 150
Temperature stability (°C) ±0.03 ±0.03 ±0.03 ±0.03
Cooling capacity (kW) 0.22 0.22 0.31 0.45
Heating capacity (kW) 2 2 2 2
Pump capacity flow rate (l/min) 15 15 15 15
Pump capacity pressure (bar) 0.35 0.35 0.35 0.35
Model
Add to compare
CORIO CD-450F
Add to compare
CORIO CD-600F
Add to compare
CORIO CD-650F
Add to compare
CORIO CD-601F
Working temperature range (°C) -30 ... 150 -35 ... 150 -40 ... 150 -35 ... 150
Temperature stability (°C) ±0.03 ±0.03 ±0.03 ±0.03
Cooling capacity (kW) 0.45 0.6 0.68 0.6
Heating capacity (kW) 2 2 2 2
Pump capacity flow rate (l/min) 15 15 15 15
Pump capacity pressure (bar) 0.35 0.35 0.35 0.35
Model
Add to compare
CORIO CD-800F
Add to compare
CORIO CD-1200F
Add to compare
CORIO CD-1200FW
Add to compare
CORIO CD-1201F
Working temperature range (°C) -40 ... 150 -40 ... 150 -40 ... 150 -40 ... 100
Temperature stability (°C) ±0.03 ±0.03 ±0.03 ±0.03
Cooling capacity (kW) 0.85 1.25 1.25 1.25
Heating capacity (kW) 2 2 2 2
Pump capacity flow rate (l/min) 15 15 15 15
Pump capacity pressure (bar) 0.35 0.35 0.35 0.35

CORIO CP refrigerated / heating circulators

with an enhanced pump performance and a temperature range up to +200 °C

Refrigerated circulators from the CORIO CP range are suitable for applications with a temperature range up to +200°C. The enhanced pump performance ensures they are suitable for easy temperature control tasks in combination with external applications.

Model
Add to compare
CORIO CP-200F
Add to compare
CORIO CP-201F
Add to compare
CORIO CP-310F
Add to compare
CORIO CP-450F
Working temperature range (°C) -20 ... 200 -20 ... 200 -30 ... 200 -30 ... 200
Temperature stability (°C) ±0.03 ±0.03 ±0.03 ±0.03
Cooling capacity (kW) 0.2 0.2 0.3 0.44
Heating capacity (kW) 2 2 2 2
Pump capacity flow rate (l/min) 8 ... 27 8 ... 27 8 ... 27 8 ... 27
Pump capacity pressure (bar) 0.1 ... 0.7 0.1 ... 0.7 0.1 ... 0.7 0.1 ... 0.7
Model
Add to compare
CORIO CP-449F
Add to compare
CORIO CP-600F
Add to compare
CORIO CP-650F
Add to compare
CORIO CP-601F
Working temperature range (°C) -32 ... 200 -35 ... 200 -40 ... 200 -35 ... 200
Temperature stability (°C) ±0.03 ±0.03 ±0.03 ±0.03
Cooling capacity (kW) 0.44 0.6 0.67 0.6
Heating capacity (kW) 2 2 2 2
Pump capacity flow rate (l/min) 8 ... 27 8 ... 27 8 ... 27 8 ... 27
Pump capacity pressure (bar) 0.1 ... 0.7 0.1 ... 0.7 0.1 ... 0.7 0.1 ... 0.7
Model
Add to compare
CORIO CP-800F
Add to compare
CORIO CP-1201F
Add to compare
CORIO CP-1200F
Add to compare
CORIO CP-1200FW
Working temperature range (°C) -40 ... 200 -40 ... 100 -50 ... 200 -50 ... 200
Temperature stability (°C) ±0.03 ±0.03 ±0.03 ±0.03
Cooling capacity (kW) 0.84 1.25 1.24 1.24
Heating capacity (kW) 2 2 2 2
Pump capacity flow rate (l/min) 8 ... 27 8 ... 27 8 ... 27 8 ... 27
Pump capacity pressure (bar) 0.1 ... 0.7 0.1 ... 0.7 0.1 ... 0.7 0.1 ... 0.7

CORIO C heating immersion circulators

The new generation of laboratory circulators

The CORIO C immersion circulator is the basic model of the CORIO circulator portfolio. The bath attachment clamp is included in delivery and facilitates mounting of the circulator on any bath tank up to 30 liters.

Model
Add to compare
CORIO C
Working temperature range (°C) 20 ... 100
Temperature stability (°C) ±0.03
Heating capacity (kW) 2
Circulation capacity flow rate (l/min) 6
Circulation capacity pressure (bar) 0.1

CORIO CD heating immersion circulators

Laboratory circulators for internal and external temperature applications until +150°C

CORIO CD heating immersion circulators can control the temperature of external applications thanks to their integrated pressure pump in conjunction with an optional pump set. The switch-over between internal and external temperature control is conveniently carried out on the front of the Unit. The bath attachment clamp supplied facilitates installation on any bath tanks up to a bath volume of 50 liters. All units offer a heating capacity of 2 kW at 230V.

Model
Add to compare
CORIO CD
Working temperature range (°C) 20 ... 150
Temperature stability (°C) ±0.03
Heating capacity (kW) 2
Pump capacity flow rate (l/min) 15
Pump capacity pressure (bar) 0.35

CORIO CP heating immersion circulators

Laboratory circulators with extended pump capacity until +200 °C

With their infinitely adjustable pressure pump, the CORIO CP heating immersion circulators achieve a flow rate of until 27 l/min. CORIO CP heating immersion circulators are suitable for a wide range of routine tasks with different pressure requirements. The supplied bath attachment clamp facilitates installation on any bath tank until a bath volume of 50 liters is reached. All units offer a heating capacity of 2 kW at 230V.

Model
Add to compare
CORIO CP
Working temperature range (°C) 20 ... 200
Temperature stability (°C) ±0.02
Heating capacity (kW) 2
Pump capacity flow rate (l/min) 8 ... 27
Pump capacity pressure (bar) 0.1 ... 0.7

CORIO C Open heating bath circulators with transparent bath tanks

Laboratory circulators for internal temperature application at working temperatures from +20 to +90°C

The open heating bath circulators of the new CORIO series feature high-quality transparent bath tanks.

Model
Add to compare
CORIO C-BT5
Add to compare
CORIO C-BT9
Add to compare
CORIO C-BT19
Add to compare
CORIO C-BT27
Working temperature range (°C) 20 ... 90 20 ... 90 20 ... 90 20 ... 90
Temperature stability (°C) ±0.03 ±0.03 ±0.03 ±0.03
Heating capacity (kW) 2 2 2 2
Circulation capacity flow rate (l/min) 6 6 6 6
Circulation capacity pressure (bar) 0.1 0.1 0.1 0.1

CORIO C with stainless steel bath tanks

Laboratory circulators for internal temperature application at working temperatures from +20 to +100°C

The open heating bath circulators of the new CORIO series feature high-quality bath tanks made of stainless steel.

Model
Add to compare
CORIO C-B5
Add to compare
CORIO C-B13
Add to compare
CORIO C-B19
Add to compare
CORIO C-B17
Working temperature range (°C) 20 ... 100 20 ... 100 20 ... 100 20 ... 100
Temperature stability (°C) ±0.03 ±0.03 ±0.03 ±0.03
Heating capacity (kW) 2 2 2 2
Circulation capacity flow rate (l/min) 6 6 6 6
Circulation capacity pressure (bar) 0.1 0.1 0.1 0.1
Model
Add to compare
CORIO C-B27
Working temperature range (°C) 20 ... 100
Temperature stability (°C) ±0.03
Heating capacity (kW) 2
Circulation capacity flow rate (l/min) 6
Circulation capacity pressure (bar) 0.1

CORIO CD with transparent open bath

for internal and external applications at working temperatures from +20 °C to +90 °C

The open heating bath circulators of the new CORIO series feature high-quality transparent bath tanks and pump connections.

Model
Add to compare
CORIO CD-BT5
Add to compare
CORIO CD-BT19
Add to compare
CORIO CD-BT27
Working temperature range (°C) 20 ... 90 20 ... 90 20 ... 90
Temperature stability (°C) ±0.03 ±0.03 ±0.03
Heating capacity (kW) 2 2 2
Pump capacity flow rate (l/min) 15 15 15
Pump capacity pressure (bar) 0.35 0.35 0.35

CORIO CD heating circulators with stainless steel open bath

for internal and external applications at workingtemperatures up to +150 °C

The open heating bath circulators of the new CORIO series feature high-quality bath tanks made of stainless steel.

Model
Add to compare
CORIO CD-B5
Add to compare
CORIO CD-B13
Add to compare
CORIO CD-B17
Add to compare
CORIO CD-B19
Working temperature range (°C) 20 ... 150 20 ... 150 20 ... 150 20 ... 150
Temperature stability (°C) ±0.03 ±0.03 ±0.03 ±0.03
Heating capacity (kW) 2 2 2 2
Pump capacity flow rate (l/min) 15 15 15 15
Pump capacity pressure (bar) 0.35 0.35 0.35 0.35
Model
Add to compare
CORIO CD-B27
Add to compare
CORIO CD-B33
Add to compare
CORIO CD-B39
Working temperature range (°C) 20 ... 150 20 ... 150 20 ... 150
Temperature stability (°C) ±0.03 ±0.03 ±0.03
Heating capacity (kW) 2 2 2
Pump capacity flow rate (l/min) 15 15 15
Pump capacity pressure (bar) 0.35 0.35 0.35

CORIO CD heating circulators

for internal and external temperature tasks with insulated stainless steel bath tanks and working temperatures from +20 °C to +150 °C

for internal and external temperature applications with stainless steel bath tanks and working temperatures from +20 °C to +150 °C

Model
Add to compare
CORIO CD-BC4
Add to compare
CORIO CD-BC6
Add to compare
CORIO CD-BC12
Add to compare
CORIO CD-BC26
Working temperature range (°C) 20 ... 150 20 ... 150 20 ... 150 20 ... 150
Temperature stability (°C) ±0.03 ±0.03 ±0.03 ±0.03
Heating capacity (kW) 2 2 2 2
Pump capacity flow rate (l/min) 15 15 15 15
Pump capacity pressure (bar) 0.35 0.35 0.35 0.35

CORIO CP heating circulators

Laboratory circulators with an expanded working temperature range up to +200 °C

CORIO circulators offer professional technology for high demands. With these devices, temperature control is optionally possible in the internal bath or in a connected external application.

Model
Add to compare
CORIO CP-BC4
Add to compare
CORIO CP-BC6
Add to compare
CORIO CP-BC12
Add to compare
CORIO CP-BC26
Working temperature range (°C) 20 ... 200 20 ... 200 20 ... 200 20 ... 200
Temperature stability (°C) ±0.02 ±0.02 ±0.02 ±0.02
Heating capacity (kW) 2 2 2 2
Pump capacity flow rate (l/min) 8 ... 27 8 ... 27 8 ... 27 8 ... 27
Pump capacity pressure (bar) 0.1 ... 0.7 0.1 ... 0.7 0.1 ... 0.7 0.1 ... 0.7