Heating Circulators with Open Bath

for internal and external temperature applications with transparent or stainless steel bath tanks and pump connections

JULABO open heating bath circulators with bath tanks made of stainless steel, Plexiglas, or Makrolon are designed for internal and external temperature applications. They are primarily used for internal temperature control directly within the bath tank. External closed systems may be connected via the integrated pump connections. Models are available with a variety of bath sizes and other functional characteristics.

A variety of bath inserts for laboratory glassware, bath covers, and adjustable floors are available as accessories. Common applications include temperature control of measurement cells, photometers, and samples; heating of glass flasks; and temperature testing of food, luxury articles, and materials.

Product Features

  • For internal and external applications
  • Bright, white, easy to read display
  • Very quiet
  • easy switching between internal and external circulation

Product Overview

CORIO CD heating circulators with stainless steel open bath

for internal and external applications at workingtemperatures up to +150 °C

The open heating bath circulators of the new CORIO series feature high-quality bath tanks made of stainless steel.

Model
Add to compare
CORIO CD-B5
Add to compare
CORIO CD-B13
Add to compare
CORIO CD-B17
Add to compare
CORIO CD-B19
Working temperature range (°C) 20 ... 150 20 ... 150 20 ... 150 20 ... 150
Temperature stability (°C) ±0.03 ±0.03 ±0.03 ±0.03
Heating capacity (kW) 2 2 2 2
Pump capacity flow rate (l/min) 15 15 15 15
Pump capacity pressure (bar) 0.35 0.35 0.35 0.35
Model
Add to compare
CORIO CD-B27
Add to compare
CORIO CD-B33
Add to compare
CORIO CD-B39
Working temperature range (°C) 20 ... 150 20 ... 150 20 ... 150
Temperature stability (°C) ±0.03 ±0.03 ±0.03
Heating capacity (kW) 2 2 2
Pump capacity flow rate (l/min) 15 15 15
Pump capacity pressure (bar) 0.35 0.35 0.35

CORIO CD with transparent open bath

for internal and external applications at working temperatures from +20 °C to +90 °C

The open heating bath circulators of the new CORIO series feature high-quality transparent bath tanks and pump connections.

Model
Add to compare
CORIO CD-BT5
Add to compare
CORIO CD-BT19
Add to compare
CORIO CD-BT27
Working temperature range (°C) 20 ... 90 20 ... 90 20 ... 90
Temperature stability (°C) ±0.03 ±0.03 ±0.03
Heating capacity (kW) 2 2 2
Pump capacity flow rate (l/min) 15 15 15
Pump capacity pressure (bar) 0.35 0.35 0.35