Heating Immersion Circulators
with attachment clamp for any bath tank up to 50 liters filling volume
JULABO immersion circulators for controlling temperature in any bath tank up to 50 liters. These units are equipped with a bath attachment clamp for wall thicknesses up to 26 mm. Alternatively, the circulator may be fastened to a laboratory stand. The clamp makes it easy to install the circulator onto an existing bath tank.
Parts that are immersed in bath liquid are constructed of high quality stainless steel or synthetic material. Common applications include controlling the temperature of samples, temperature testing of food or luxury articles, materials testing, and evaluation, adjustment, and calibration or thermometers and thermal switches
Product Features
- Complete selection of models for internal and external applications
- High heating capacities
- Very quiet
Product Overview
CORIO C Heating Immersion Circulators
The new generation of laboratory circulators
The CORIO C Immersion Circulator is the basic model of the CORIO circulator portfolio. The bath attachment clamp is included in delivery and facilitates mounting of the circulator on any bath tank up to 30 liters.

Model | CORIO C |
---|---|
Order No. | 9 011 000 |
Working temperature range (°C) | +20 ... +100 |
Temperature stability (°C) | ±0.03 |
Heating capacity (kW) | 2 |
Circulation capacity flow rate (l/min) | 6 |
Circulation capacity pressure (bar) | 0.1 |
CORIO CD Heating Immersion Circulators
The new generation of laboratory circulators
In addition to the advantages of the CORIO C Circulator, the CORIO CD Immersion Circulator can be equipped with an optional pump set for temperature control of external applications.

Model | CORIO CD |
---|---|
Order No. | 9 012 000 |
Working temperature range (°C) | +20 ... +150 |
Temperature stability (°C) | ±0.03 |
Heating capacity (kW) | 2 |
Pump capacity flow rate (l/min) | 15 |
Pump capacity flow pressure (bar) | 0.35 |
CORIO CP Heating Immersion Circulators
Laboratory Circulators with an expanded working temperature range up to +200 °C
In addition to the advantages of the CORIO C Circulator, the CORIO CD and CP Immersion Circulator can be equipped with an optional pump set for temperature control of external applications.

Model | CORIO CP |
---|---|
Order No. | 9 013 000 |
Working temperature range (°C) | +20 ... +200 |
Temperature stability (°C) | ±0.02 |
Heating capacity (kW) | 2 |
Pump capacity flow rate (l/min) | 8 ... 27 |
Pump capacity flow pressure (bar) | 0.1 ... 0.7 |
DYNEO DD Heating Immersion Circulators
Flexible laboratory circulators with a new operating concept
DYNEO DD heating circulators for internal and external applications are equipped with closed bath tanks. The tanks are well insulated and include a coil for counter-cooling. An integrated drain tap makes emptying the tank safe and clean. The multilingual 3.5-inch color display and unique rotary knob provide for straightforward and intuitive operation.

Model | DYNEO DD |
---|---|
Order No. | 9 021 000 |
Working temperature range (°C) | +20 ... +200 |
Temperature stability (°C) | ±0.01 |
Heating capacity (kW) | 2 |
Pump capacity flow rate (l/min) | 8 ... 27 |
Pump capacity flow pressure (bar) | 0.1 ... 0.7 |