Performance data depends on the mains voltage in the country of use. Please select:
Country of use | Mains voltage | Plug | JULABO voltage version code
CORIO CP-BC6
Order number including voltage version
9013506.04
Working temperature range
1
20 ... 200 °C
Temperature stability
±0.02 °C
Heating capacity
2 kW
Pump capacity flow rate
8 ... 27 l/min
Pump capacity pressure
0.1 ... 0.7 bar
Usable bath opening(W x L / D)
13 x 15 / 20 cm
Filling volume
6 ... 7.5 l
Total dimensions
(W × L × H)
24 x 44 x 47 cm
1 For applications near or below ambient temperature: use a cooling coil or JULABO immersion cooler.
Models for internal and external applications
Bright, white, easy to read display
Very quiet
easy switching between internal and external circulation
powerful and infinitely adjustable pressure pump
USB connection
RS232 interface for online communication
High-quality bath tanks made of stainless steel with bath lid and drain tap
Integrated pump connection M16×1
Integrated cooling coil for counter-cooling with 9,5mm outer diameter
Easy operation
Technical data for CORIO CP-BC6
Dimensions and volumes
Total dimensions(W × L × H)
24 x 44 x 47 cm
Filling volume
6 ... 7.5 l
Weight
10 kg
Pump connections
M16x1 male
Barbed fittings inner diameter
8/12 mm
Temperature values
Working temperature range
1
20 ... 200 °C
Temperature stability
±0.02 °C
Temperature display resolution
0.01 °C
Ambient temperature
+5 ... +40 °C
1 For applications near or below ambient temperature: use a cooling coil or JULABO immersion cooler.
Performance data depends on the mains voltage in the country of use. Please select:
Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Heating capacity
2 kW
Pump capacity flow rate
8 ... 27 l/min
Pump capacity pressure
0.1 ... 0.7 bar
Viscosity max.
50 cSt
Power consumption
10 A
Bath
Bath tank
Stainless steel
Bath cover
integrated
Usable bath opening(W x L / D)
13 x 15 / 20 cm
Other
Classification
according to DIN12876-1
Classification III (FL)
Pump function
Pressure Pump
Pump type
Immersion Pump
Electronics
Interfaces
RS232 / USB
Temperature control
PID1
Absolute temperature calibration
3 Point Calibration
Temperature display
LED
Temperature setting
Keypad
Electronic Timer
h:min
0 ... 999
Available voltage versions
9013506.33
200-230V 50/60Hz (Schuko Plug - CEE 7/4 Plug Type F)
9013506.33.chn
200-230V 50/60Hz (CN Plug)
9013506.04
200-230V 50/60Hz (UK Plug Type BS1363A)
9013506.05
200-230V 50/60Hz (CH Plug Type SEV 1011)
9013506.22
100-115V 50/60Hz (Nema N5-15 Plug)
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)
Add to quotation request
Contact expert
Heat-up time
Medium: Thermal
Pump capacity
Medium: Water
Accessory for CORIO CP-BC6
Downloads for CORIO CP-BC6
We would also be happy to send you our printed catalogs and brochures by post.
Request brochure