VALEGRO Recirculating Coolers

Modern, user-friendly chillers for a wide range of cooling tasks

The new VALEGRO recirculating coolers are environmentally friendly all-rounders for a wide range of cooling and heating tasks. They are characterized by a good ratio between cooling capacity and unit size as well as an optimal usability.

The modern devices offer precise temperature control for a wide range of applications in laboratories, industry, and research. Their compact design allows them to fit seamlessly into any working environment. They use an eco-friendly, natural refrigerant and can be ideally adapted to the requirements of the customer's application thanks to an adjustable pump. During the design of the VALEGRO recirculating coolers, the focus was on maximum user-friendliness. Many helpful features such as a timer function, a removable venting grid that can be removed without tools, and an illuminated, easy-to-clean level indicator make everyday work easier. The inclined OLED touch display is easy to read and ergonomic to use. With the intuitive menu navigation, all functions can be accessed simple and quickly. Clear warnings and understandable messages secure safe handling of the units at all times. In addition to RS232 and USB-C interfaces, VALEGRO recirculating coolers are also available with Ethernet (optional). All interfaces are located directly below the display and are easy to access from the front.

Product Features

  • Climate-friendly thanks to natural refrigerant
  • OLED touch display with intuitive menu navigation
  • Good ratio between cooling capacity and size
  • USB-C and RS232 as standard, Ethernet available as option
  • Illuminated, easy-to-clean level indicator

Product Overview

VALEGRO Recirculating Coolers

with cooling capacities of 0.35 - 1.8 kW

The air-cooled VALEGRO recirculating coolers are environmentally friendly all-rounders for a wide range of cooling and heating tasks from -20 to +40 °C. The pump can be user-friendly adjusted in different pump stages on a percentage basis.

Model
Add to compare
VALEGRO 350
Add to compare
VALEGRO 500
Add to compare
VALEGRO 801
Add to compare
VALEGRO 1001
Working temperature range (°C) -20 ... 40 -20 ... 40 -20 ... 40 -20 ... 40
Temperature stability (°C) ±0.3 ±0.3 ±0.3 ±0.3
Cooling capacity (kW) 0.35 0.5 0.8 1
Pump capacity flow rate (l/min) 7 ... 16 7 ... 19 15 ... 23 15 ... 23
Pump capacity pressure (bar) 0.15 ... 0.6 0.15 ... 0.85 0.5 ... 1.1 0.5 ... 1.1
Model
Add to compare
VALEGRO 1201
Add to compare
VALEGRO 1501
Add to compare
VALEGRO 1801
Working temperature range (°C) -20 ... 40 -20 ... 40 -20 ... 40
Temperature stability (°C) ±0.3 ±0.3 ±0.3
Cooling capacity (kW) 1.2 1.5 1.8
Pump capacity flow rate (l/min) 15 ... 23 15 ... 23 15 ... 23
Pump capacity pressure (bar) 0.5 ... 1.1 0.5 ... 1.1 0.5 ... 1.1

VALEGRO Recirculating Coolers with Extended Temperature Range

with cooling capacities of 0.8 - 1.8 kW

VALEGRO recirculating coolers with additional heating function have an extended working temperature range from -20 to +85 °C. The pump can be easily adjusted in user-friendly, percentage-based stages.

Model
Add to compare
VALEGRO 801H
Add to compare
VALEGRO 1001H
Add to compare
VALEGRO 1201H
Add to compare
VALEGRO 1501H
Working temperature range (°C) -20 ... 85 -20 ... 85 -20 ... 85 -20 ... 85
Temperature stability (°C) ±0.2 ±0.2 ±0.2 ±0.2
Cooling capacity (kW) 0.8 1 1.2 1.5
Pump capacity flow rate (l/min) 15 ... 23 15 ... 23 15 ... 23 15 ... 23
Pump capacity pressure (bar) 0.5 ... 1.1 0.5 ... 1.1 0.5 ... 1.1 0.5 ... 1.1
Model
Add to compare
VALEGRO 1801H
Working temperature range (°C) -20 ... 85
Temperature stability (°C) ±0.2
Cooling capacity (kW) 1.8
Pump capacity flow rate (l/min) 15 ... 23
Pump capacity pressure (bar) 0.5 ... 1.1

VALEGRO Recirculating Coolers with Increased Pump Capacity

with cooling capacities of 1.2 - 2.5 kW

The more powerful VALEGRO recirculating coolers are designed for larger and more complex applications. They feature a precisely adjustable, increased pump pressure up to 3.5 bar.

Model
Add to compare
VALEGRO 1203
Add to compare
VALEGRO 1503
Add to compare
VALEGRO 1803
Add to compare
VALEGRO 2503
Working temperature range (°C) -20 ... 40 -20 ... 40 -20 ... 40 -20 ... 40
Temperature stability (°C) ±0.3 ±0.3 ±0.3 ±0.3
Cooling capacity (kW) 1.2 1.5 1.8 2.5
Pump capacity flow rate (l/min) 15 ... 40 15 ... 40 15 ... 40 15 ... 40
Pump capacity pressure (bar) 0.5 ... 3.5 0.5 ... 3.5 0.5 ... 3.5 0.5 ... 3.5

VALEGRO Recirculating Coolers with Extended Temperature Range and Increased Pump Capacity

with cooling capacities of 1.2 - 2.5 kW

The advanced VALEGRO recirculating coolers meet even the most demanding requirements, featuring an additional heating function and a powerful, pressure-controlled pump. They offer flexible operation and maximum safety in every application.

Model
Add to compare
VALEGRO 1203H
Add to compare
VALEGRO 1503H
Add to compare
VALEGRO 1803H
Add to compare
VALEGRO 2503H
Working temperature range (°C) -20 ... 85 -20 ... 85 -20 ... 85 -20 ... 85
Temperature stability (°C) ±0.2 ±0.2 ±0.2 ±0.2
Cooling capacity (kW) 1.2 1.5 1.8 2.5
Pump capacity flow rate (l/min) 15 ... 40 15 ... 40 15 ... 40 15 ... 40
Pump capacity pressure (bar) 0.5 ... 3.5 0.5 ... 3.5 0.5 ... 3.5 0.5 ... 3.5