MA Heating Immersion Circulator
Middle class for a broad range of applications -20°C...200°C
Heating Immersion Circulator for any bath tanks up to 50 liters
JULABO Heating Immersion Circulators are available for various bath tanks up to a capacity of 50 litres and come equipped with a bath clamp that fits onto all tanks with a wall thickness up to 26 mm. This clamp allows fast and problem-free assembling for existing as well as new bath tanks. The immersion depth is 16.5 cm (adjustable down to 14.5 cm). The immersed parts are made of high-quality stainless steel or plastic. The pump set, which is available as an accessory, provides pumping to external systems for provision of external temperature tasks. An integrated cooling coil for cooling-water connection is also available as an accessory.
Your advantages
- MULTI-DISPLAY (LED) for actual and setpoint values, warning/safety functions and pump stage
- Keypad for setpoints, warning/safety values and menu functions
- PID2 temperature control with drift compensation
- ATC3 3-Point-Calibration
- Early warning system for low liquid level (DBGM 203 06 059.8)
- Adjustable high temperature cut-out, visible via display
- RS232 interface for online communication
- SMART PUMP, electronically adjustable pump stages
Technical Data
| Order No. | 9153000 |
|---|---|
| Model series | TopTech |
| Category | Heating Immersion Circulators |
| Working temperature range (°C) | +20 ... +200 |
| Temperature stability (°C) | ±0.01 |
| Setting / display resolution | 0.01 (-9.99...99.99) / 0.1 °C |
| Temperature Display | LED |
| Heating capacity (kW) | 1 |
| Pump capacity flow rate (l/min) | 11-16 |
| Pump capacity flow pressure (psi) | 3.3-6.5 |
| Digital interfaces |
RS232 Optional Profibus |
| Ambient temperature | 5...40 °C |
| Dimensions W x L x H (inch) | 5.1 x 5.9 x 13 |
| Weight (LBS) | 9 |
| Classification according to DIN12876-1 | Classification III (FL) |
| Description | For temperature applications near or below ambient temperature: use a cooling coil or JULABO immersion cooler. |
| Cooling coil | optional |
| Power requirement V / Hz / A | 115/60/9 Additional voltage versions available |
Characteristics
Large Multi-Display (LED), easy to read across the room, for actual value and up to 3 setpoints, warning functions, high temperature cut-off, selected pump stages (resolution 0.01/0.1 °C)
Comfortable keypad with additional menu functions for pump stages, calibration, control parameters, programmer, warnings, etc.
PID Temperature control with drift compensation and adjustable control parameters, temperature stability ±0.01...±0.02 °C
‘Absolute Temperature Calibration’ for manual compensation of a temperature difference, 3-point calibration
Reliable and consistent pump capacity, electronically adjustable pump stages
RS232 interface for PC connection, e.g. for data communication and recording of measured values
Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down
Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function
Adjustable high temperature cut-off or dry-running protection
Classification III (FL) according to DIN 12876-1
Other characteristics
Installation cooling coil and pump set for external applications available as accessory.
Technical changes without prior notification.
Images may deviate from the original.
We would be pleased to submit a non-binding offer for the selected product or answer all pertinent questions.
click here for quotation request MASearch
Contact
JULABO USA Inc.
884 Marcon Boulevard
Allentown, PA 18109
Phone: 610-231-0250
Phone: 800-458-5226
(Toll-Free)
sales@julabo.us
julabo.us
Contact form
Available voltage versions
Order No.: 9153000
230 V / 50-60 Hz
100-115 V / 50-60 Hz