Cryostats
Welcome to JULABO cryostats: Highest precision for your cooling application
Cryostats from JULABO set new standards in terms of precision, performance and hassle-free operation. Thanks to their strong cooling performance and ability to maintain constant temperatures even under extreme conditions, they are the preferred choice in research, industry and academic institutions worldwide. Our cryostats not only offer the highest accuracy in temperature control, but also exceptional energy efficiency, resulting in cost savings and more sustainable use. Whether for sophisticated experiments, sensitive production processes or innovative research projects, rely on the proven quality and performance of our JULABO cryostats for your demanding cooling applications.
Why JULABO cryostats?
Precision: Thanks to state-of-the-art technology and decades of experience, our cryostats offer unparalleled temperature stability and accuracy.
Performance: With powerful cooling machines and innovative control technology, our cryostats deliver constant cooling, even under extreme conditions.
Flexibility: JULABO cryostats are available in different sizes, configurations and performance classes to meet the requirements of your application.
Reliability: Our cryostats are manufactured to the highest standards and are subject to strict quality controls to ensure long-term, hassle-free use.
Cryostats with the right functionality for your application
CORIO cryostats
Cryostats in the CORIO series offer the best price-performance ratio. Equipped with all the important core functions, CORIO cryostats are optimized for simple, daily routine work and are an integral part of many laboratories at research institutions and industrial companies worldwide.
DYNEO cryostats
With DYNEO cryostats, we offer our customers the ideal units for internal and external applications in a wide working temperature range from -50 °C until +200 °C. Whether in basic research, materials testing or technical systems - DYNEO cryostats offer functional solutions for every requirement and every budget.
MAGIO cryostats
The cryostats in the MAGIO series are high-end units in the highest performance class with a large working temperature range from -50 °C until +300 °C. The units offer extra powerful pressure and suction pumps and therefore meet the highest requirements for temperature control of demanding external applications.
Structure and components of cryostats
Cryostats from JULABO are state-of-the-art units for precise and hassle-free temperature control. Their design comprises four central components. The compressor compresses the cooling liquid and increases its pressure and temperature. In the condenser, the hot, compressed cooling liquid is cooled down and liquified by radiating heat to the ambient air. An expansion valve usually regulates the discharge of the cooling liquid into the evaporator and lowers its pressure, causing the coolant to expand and cool down. In the evaporator, the cooling liquid evaporates, absorbing heat from the temperature control medium and thereby cooling it down.
The cryostats have microprocessor controls that enable precise temperature monitoring and control. Safety functions and warning systems ensure hassle-free operation. All parts that come into contact with the cooling medium consist of stainless steel or high-quality plastics for durability and chemical resistance. Many models have pump connections for external temperature control applications and a bath opening for smaller samples.
JULABO cryostats at a glance
CORIO CD refrigerated / heating circulators
The new generation of laboratory circulators for routine work and standard tasks
Refrigerated / heating circulators of the CORIO CD series distinguish themselves with a great price-to-performance ratio. Durable and dependable, they are suitable for a wide range of standard and routine work in both laboratories and industrial environments.
| Model | Add to compare CORIO CD-200F |
Add to compare CORIO CD-201F |
Add to compare CORIO CD-310F |
Add to compare CORIO CD-449F |
|---|---|---|---|---|
| Working temperature range (°C) | -20 ... 150 | -20 ... 150 | -30 ... 150 | -32 ... 150 |
| Temperature stability (°C) | ±0.03 | ±0.03 | ±0.03 | ±0.03 |
| Cooling capacity (kW) | 0.22 | 0.22 | 0.31 | 0.45 |
| Heating capacity (kW) | 2 | 2 | 2 | 2 |
| Pump capacity flow rate (l/min) | 15 | 15 | 15 | 15 |
| Pump capacity pressure (bar) | 0.35 | 0.35 | 0.35 | 0.35 |
| Model | Add to compare CORIO CD-450F |
Add to compare CORIO CD-600F |
Add to compare CORIO CD-601F |
Add to compare CORIO CD-800F |
|---|---|---|---|---|
| Working temperature range (°C) | -30 ... 150 | -35 ... 150 | -35 ... 150 | -40 ... 150 |
| Temperature stability (°C) | ±0.03 | ±0.03 | ±0.03 | ±0.03 |
| Cooling capacity (kW) | 0.45 | 0.6 | 0.6 | 0.85 |
| Heating capacity (kW) | 2 | 2 | 2 | 2 |
| Pump capacity flow rate (l/min) | 15 | 15 | 15 | 15 |
| Pump capacity pressure (bar) | 0.35 | 0.35 | 0.35 | 0.35 |
| Model | Add to compare CORIO CD-1200F |
Add to compare CORIO CD-1200FW |
Add to compare CORIO CD-1201F |
|---|---|---|---|
| Working temperature range (°C) | -40 ... 150 | -40 ... 150 | -40 ... 100 |
| Temperature stability (°C) | ±0.03 | ±0.03 | ±0.03 |
| Cooling capacity (kW) | 1.25 | 1.25 | 1.25 |
| Heating capacity (kW) | 2 | 2 | 2 |
| Pump capacity flow rate (l/min) | 15 | 15 | 15 |
| Pump capacity pressure (bar) | 0.35 | 0.35 | 0.35 |
CORIO CP refrigerated / heating circulators
with an enhanced pump performance and a temperature range up to +200 °C
Refrigerated circulators from the CORIO CP range are suitable for applications with a temperature range up to +200°C. The enhanced pump performance ensures they are suitable for easy temperature control tasks in combination with external applications.
| Model | Add to compare CORIO CP-200F |
Add to compare CORIO CP-201F |
Add to compare CORIO CP-310F |
Add to compare CORIO CP-450F |
|---|---|---|---|---|
| Working temperature range (°C) | -20 ... 200 | -20 ... 200 | -30 ... 200 | -30 ... 200 |
| Temperature stability (°C) | ±0.03 | ±0.03 | ±0.03 | ±0.03 |
| Cooling capacity (kW) | 0.2 | 0.2 | 0.3 | 0.44 |
| Heating capacity (kW) | 2 | 2 | 2 | 2 |
| Pump capacity flow rate (l/min) | 8 ... 27 | 8 ... 27 | 8 ... 27 | 8 ... 27 |
| Pump capacity pressure (bar) | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 |
| Model | Add to compare CORIO CP-449F |
Add to compare CORIO CP-600F |
Add to compare CORIO CP-601F |
Add to compare CORIO CP-800F |
|---|---|---|---|---|
| Working temperature range (°C) | -32 ... 200 | -35 ... 200 | -35 ... 200 | -40 ... 200 |
| Temperature stability (°C) | ±0.03 | ±0.03 | ±0.03 | ±0.03 |
| Cooling capacity (kW) | 0.44 | 0.6 | 0.6 | 0.84 |
| Heating capacity (kW) | 2 | 2 | 2 | 2 |
| Pump capacity flow rate (l/min) | 8 ... 27 | 8 ... 27 | 8 ... 27 | 8 ... 27 |
| Pump capacity pressure (bar) | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 |
| Model | Add to compare CORIO CP-1201F |
Add to compare CORIO CP-1200F |
Add to compare CORIO CP-1200FW |
|---|---|---|---|
| Working temperature range (°C) | -40 ... 100 | -50 ... 200 | -50 ... 200 |
| Temperature stability (°C) | ±0.03 | ±0.03 | ±0.03 |
| Cooling capacity (kW) | 1.25 | 1.24 | 1.24 |
| Heating capacity (kW) | 2 | 2 | 2 |
| Pump capacity flow rate (l/min) | 8 ... 27 | 8 ... 27 | 8 ... 27 |
| Pump capacity pressure (bar) | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 |
DYNEO DD refrigerated / heating circulators
New temperature control technology for demanding applications
Refrigerated circulators of the DYNEO series distinguish themselves with a great price-performance ratio. The instruments offer high heating/cooling capacities for short heat-up and cool-down times. The refrigerated circulators work precisely and reliably even at higher ambient temperatures up to +40 °C. Either in basic research, in material testing or in technical systems – the DYNEO refrigerated circulators offer functional solutions for every requirement and budget.
| Model | Add to compare DYNEO DD-200F |
Add to compare DYNEO DD-201F |
Add to compare DYNEO DD-310F |
Add to compare DYNEO DD-449F |
|---|---|---|---|---|
| Working temperature range (°C) | -20 ... 200 | -20 ... 200 | -30 ... 200 | -32 ... 200 |
| Temperature stability (°C) | ±0.01 | ±0.01 | ±0.01 | ±0.01 |
| Cooling capacity (kW) | 0.2 | 0.2 | 0.3 | 0.44 |
| Heating capacity (kW) | 2 | 2 | 2 | 2 |
| Pump capacity flow rate (l/min) | 8 ... 27 | 8 ... 27 | 8 ... 27 | 8 ... 27 |
| Pump capacity pressure (bar) | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 |
| Model | Add to compare DYNEO DD-450F |
Add to compare DYNEO DD-600F |
Add to compare DYNEO DD-601F |
Add to compare DYNEO DD-800F |
|---|---|---|---|---|
| Working temperature range (°C) | -30 ... 200 | -35 ... 200 | -35 ... 200 | -40 ... 200 |
| Temperature stability (°C) | ±0.01 | ±0.01 | ±0.01 | ±0.01 |
| Cooling capacity (kW) | 0.44 | 0.6 | 0.6 | 0.84 |
| Heating capacity (kW) | 2 | 2 | 2 | 2 |
| Pump capacity flow rate (l/min) | 8 ... 27 | 8 ... 27 | 8 ... 27 | 8 ... 27 |
| Pump capacity pressure (bar) | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 |
| Model | Add to compare DYNEO DD-1201F |
Add to compare DYNEO DD-1200F |
Add to compare DYNEO DD-1200FW |
|---|---|---|---|
| Working temperature range (°C) | -40 ... 100 | -50 ... 200 | -50 ... 200 |
| Temperature stability (°C) | ±0.01 | ±0.01 | ±0.01 |
| Cooling capacity (kW) | 1.25 | 1.24 | 1.24 |
| Heating capacity (kW) | 1.5 | 2 | 2 |
| Pump capacity flow rate (l/min) | 8 ... 27 | 8 ... 27 | 8 ... 27 |
| Pump capacity pressure (bar) | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 |
MAGIO MS refrigerated / heating circulators
with extremely powerful pressure/suction pump and intuitive touch display
As with all circulators from the MAGIO range, the refrigerated circulators stand out thanks to their premium quality, high performance and intuitive operation. The devices offer extra strong pressure and suction pumps, thus fulfilling the highest demands for temperature control of external applications. Whether in basic research, material testing or technical systems – the MAGIO refrigerated circulators offer high-tech solutions for high customer requirements.
| Model | Add to compare MAGIO MS-310F |
Add to compare MAGIO MS-449F |
Add to compare MAGIO MS-450F |
Add to compare MAGIO MS-600F |
|---|---|---|---|---|
| Working temperature range (°C) | -30 ... 200 | -30 ... 200 | -30 ... 200 | -35 ... 200 |
| Temperature stability (°C) | ±0.01 | ±0.01 | ±0.01 | ±0.01 |
| Cooling capacity (kW) | 0.33 | 0.46 | 0.46 | 0.6 |
| Heating capacity (kW) | 2 | 2 | 2 | 2 |
| Pump capacity flow rate (l/min) | 16 ... 31 | 16 ... 31 | 16 ... 31 | 16 ... 31 |
| Pump capacity pressure (bar) | 0.24 ... 0.92 | 0.24 ... 0.92 | 0.24 ... 0.92 | 0.24 ... 0.92 |
| Model | Add to compare MAGIO MS-601F |
Add to compare MAGIO MS-800F |
Add to compare MAGIO MS-1200F |
Add to compare MAGIO MS-1200FW |
|---|---|---|---|---|
| Working temperature range (°C) | -35 ... 200 | -40 ... 200 | -50 ... 200 | -50 ... 200 |
| Temperature stability (°C) | ±0.01 | ±0.01 | ±0.01 | ±0.01 |
| Cooling capacity (kW) | 0.6 | 0.86 | 1.26 | 1.26 |
| Heating capacity (kW) | 2 | 2 | 2 | 2 |
| Pump capacity flow rate (l/min) | 16 ... 31 | 16 ... 31 | 16 ... 31 | 16 ... 31 |
| Pump capacity pressure (bar) | 0.24 ... 0.92 | 0.24 ... 0.92 | 0.24 ... 0.92 | 0.24 ... 0.92 |
MAGIO MX refrigerated / heating circulators
Our most powerful laboratory circulators with the highest cooling and heating capacity
As with all circulators from the MAGIO range, the refrigerated circulators stand out thanks to their premium quality, high performance and intuitive operation. These devices provide extra powerful pressure and suction pumps and have an incredibly high heating output of 3 kW, enabling even more dynamic temperature control for external applications.
| Model | Add to compare MAGIO MX-1800F |
Add to compare MAGIO MX-2500F |
|---|---|---|
| Working temperature range (°C) | -50 ... 200 | -50 ... 200 |
| Temperature stability (°C) | ±0.01 | ±0.01 |
| Cooling capacity (kW) | 1.87 | 2.5 |
| Heating capacity (kW) | 1.9 | 3 |
| Pump capacity flow rate (l/min) | 16 ... 31 | 16 ... 31 |
| Pump capacity pressure (bar) | 0.24 ... 0.92 | 0.24 ... 0.92 |
Why JULABO?
With over 50 years of experience in temperature control and refrigeration technology, JULABO is one of the leading manufacturers on the market. Our dedicated team of experts is always on hand to help you choose the right cryostat and answer any other questions you may have.
Contact us today
Ready to experience the future of refrigeration? Contact us today to find out more about our cryostats or to receive a personalized quote. We look forward to helping you and providing you with the best possible solution for your requirements.