VALEGRO Recirculating Coolers

Modern, user-friendly chillers for a wide range of cooling tasks

The new VALEGRO recirculating coolers are environmentally friendly all-rounders for a wide range of heating and cooling tasks. The modern chillers offer an optimal ratio between cooling capacity and unit size combined with a high level of user-friendliness.

Whether in the laboratory, in research, or in industrial production, VALEGRO recirculating coolers are reliable partners whenever precise temperature control is required. Thanks to their compact design and quiet operation, they fit seamlessly into any working environment. All models use an environmentally friendly, natural refrigerant and can be ideally adapted to the requirements of a wide range of customer applications thanks to the continuously adjustable pump.

During the development of the VALEGRO recirculating coolers, the focus was on maximum user-friendliness. Many helpful features make everyday work easier. These include a timer function, a venting grid that can be removed without tools, and an illuminated, easy-to-clean level indicator. The inclined OLED touch display is easy to read and ergonomic to use. With the intuitive menu navigation, all functions can be accessed simply and quickly. Clear warnings and understandable messages ensure safe and convenient operation of the units at all times. In addition to RS232 and USB-C interfaces, VALEGRO recirculating coolers are also available with Ethernet as an option. All interfaces are located directly below the display and are easily accessible from the front.

Product Features

  • Climate-friendly thanks to natural refrigerant
  • OLED touch display with intuitive menu navigation
  • Good ratio between cooling capacity and size
  • PID temperature control

Product Overview

VALEGRO Recirculating Coolers

with cooling capacities of 0.25 - 1.8 kW

The air-cooled VALEGRO recirculating coolers are environmentally friendly all-rounders for a wide range of cooling and heating tasks from -20 to 40 °C. The pump output can be easily and continuously adjusted.

Model
Add to compare
VALEGRO 250
Add to compare
VALEGRO 350
Add to compare
VALEGRO 500
Add to compare
VALEGRO 801
Working temperature range (°C) -15 ... 40 -20 ... 40 -20 ... 40 -20 ... 40
Temperature stability (°C) ±0.5 ±0.3 ±0.3 ±0.3
Cooling capacity (kW) 0.25 0.35 0.5 0.8
Pump capacity flow rate (l/min) 11 ... 22 7 ... 16 7 ... 19 15 ... 23
Pump capacity pressure (bar) 0.1 ... 0.4 0.15 ... 0.6 0.15 ... 0.85 0.5 ... 1.1
Model
Add to compare
VALEGRO 1001
Add to compare
VALEGRO 1201
Add to compare
VALEGRO 1501
Add to compare
VALEGRO 1801
Working temperature range (°C) -20 ... 40 -20 ... 40 -20 ... 40 -20 ... 40
Temperature stability (°C) ±0.3 ±0.3 ±0.3 ±0.3
Cooling capacity (kW) 1 1.2 1.5 1.8
Pump capacity flow rate (l/min) 15 ... 23 15 ... 23 15 ... 23 15 ... 23
Pump capacity pressure (bar) 0.5 ... 1.1 0.5 ... 1.1 0.5 ... 1.1 0.5 ... 1.1

VALEGRO Recirculating Coolers with Extended Temperature Range

with cooling capacities of 0.8 - 1.8 kW

VALEGRO recirculating coolers with an additional heating function have an extended working temperature range of -20 to +85 °C. The pump output can be easily and continuously adjusted.

Model
Add to compare
VALEGRO 801H
Add to compare
VALEGRO 1001H
Add to compare
VALEGRO 1201H
Add to compare
VALEGRO 1501H
Working temperature range (°C) -20 ... 85 -20 ... 85 -20 ... 85 -20 ... 85
Temperature stability (°C) ±0.2 ±0.2 ±0.2 ±0.2
Cooling capacity (kW) 0.8 1 1.2 1.5
Pump capacity flow rate (l/min) 15 ... 23 15 ... 23 15 ... 23 15 ... 23
Pump capacity pressure (bar) 0.5 ... 1.1 0.5 ... 1.1 0.5 ... 1.1 0.5 ... 1.1
Model
Add to compare
VALEGRO 1801H
Working temperature range (°C) -20 ... 85
Temperature stability (°C) ±0.2
Cooling capacity (kW) 1.8
Pump capacity flow rate (l/min) 15 ... 23
Pump capacity pressure (bar) 0.5 ... 1.1

VALEGRO Recirculating Coolers with Increased Pump Capacity

with cooling capacities of 1.2 - 2.5 kW

The more powerful VALEGRO recirculating coolers are designed for larger and more complex applications. They feature a precisely adjustable, increased pump pressure up to 3.5 bar.

Model
Add to compare
VALEGRO 1203
Add to compare
VALEGRO 1503
Add to compare
VALEGRO 1803
Add to compare
VALEGRO 2503
Working temperature range (°C) -20 ... 40 -20 ... 40 -20 ... 40 -20 ... 40
Temperature stability (°C) ±0.3 ±0.3 ±0.3 ±0.3
Cooling capacity (kW) 1.2 1.5 1.8 2.5
Pump capacity flow rate (l/min) 15 ... 40 15 ... 40 15 ... 40 15 ... 40
Pump capacity pressure (bar) 0.5 ... 3.5 0.5 ... 3.5 0.5 ... 3.5 0.5 ... 3.5

VALEGRO Recirculating Coolers with Extended Temperature Range and Increased Pump Capacity

with cooling capacities of 1.2 - 2.5 kW

The advanced VALEGRO recirculating coolers meet even the most demanding requirements, featuring an additional heating function and a powerful, pressure-controlled pump. They offer flexible operation and maximum safety in every application.

Model
Add to compare
VALEGRO 1203H
Add to compare
VALEGRO 1503H
Add to compare
VALEGRO 1803H
Add to compare
VALEGRO 2503H
Working temperature range (°C) -20 ... 85 -20 ... 85 -20 ... 85 -20 ... 85
Temperature stability (°C) ±0.2 ±0.2 ±0.2 ±0.2
Cooling capacity (kW) 1.2 1.5 1.8 2.5
Pump capacity flow rate (l/min) 15 ... 40 15 ... 40 15 ... 40 15 ... 40
Pump capacity pressure (bar) 0.5 ... 3.5 0.5 ... 3.5 0.5 ... 3.5 0.5 ... 3.5