VALEGRO Recirculating Coolers

VALEGRO recirculating coolers combine modern and sustainable technology with a high level of user-friendliness. They are versatile and ensure precise temperature control for laboratories, industry and research – at working temperatures from -20 to +85 °C, depending on the model.
VALEGRO coolers from 800 watts cooling capacity are particularly energy-efficient thanks to speed-controlled compressors and fans.

Sustainable lab cooling – how to reduce energy use with VALEGRO

VALEGRO Recirculating Coolers

with cooling capacities of 0.35 - 1.8 kW

The air-cooled VALEGRO recirculating coolers are environmentally friendly all-rounders for a wide range of cooling and heating tasks from -20 to +40 °C. The pump can be user-friendly adjusted in different pump stages on a percentage basis.

Model
Add to compare
VALEGRO 350
Add to compare
VALEGRO 500
Add to compare
VALEGRO 801
Add to compare
VALEGRO 1001
Working temperature range (°C) -20 ... 40 -20 ... 40 -20 ... 40 -20 ... 40
Temperature stability (°C) ±0.3 ±0.3 ±0.3 ±0.3
Cooling capacity (kW) 0.35 0.5 0.8 1
Pump capacity flow rate (l/min) 7 ... 16 7 ... 19 15 ... 23 15 ... 23
Pump capacity pressure (bar) 0.15 ... 0.6 0.15 ... 0.85 0.5 ... 1.1 0.5 ... 1.1
Model
Add to compare
VALEGRO 1201
Add to compare
VALEGRO 1501
Add to compare
VALEGRO 1801
Working temperature range (°C) -20 ... 40 -20 ... 40 -20 ... 40
Temperature stability (°C) ±0.3 ±0.3 ±0.3
Cooling capacity (kW) 1.2 1.5 1.8
Pump capacity flow rate (l/min) 15 ... 23 15 ... 23 15 ... 23
Pump capacity pressure (bar) 0.5 ... 1.1 0.5 ... 1.1 0.5 ... 1.1

VALEGRO Recirculating Coolers with Extended Temperature Range

with cooling capacities of 0.8 - 1.8 kW

VALEGRO recirculating coolers with additional heating function have an extended working temperature range from -20 to +85 °C. The pump can be easily adjusted in user-friendly, percentage-based stages.

Model
Add to compare
VALEGRO 801H
Add to compare
VALEGRO 1001H
Add to compare
VALEGRO 1201H
Add to compare
VALEGRO 1501H
Working temperature range (°C) -20 ... 85 -20 ... 85 -20 ... 85 -20 ... 85
Temperature stability (°C) ±0.2 ±0.2 ±0.2 ±0.2
Cooling capacity (kW) 0.8 1 1.2 1.5
Pump capacity flow rate (l/min) 15 ... 23 15 ... 23 15 ... 23 15 ... 23
Pump capacity pressure (bar) 0.5 ... 1.1 0.5 ... 1.1 0.5 ... 1.1 0.5 ... 1.1
Model
Add to compare
VALEGRO 1801H
Working temperature range (°C) -20 ... 85
Temperature stability (°C) ±0.2
Cooling capacity (kW) 1.8
Pump capacity flow rate (l/min) 15 ... 23
Pump capacity pressure (bar) 0.5 ... 1.1

VALEGRO Recirculating Coolers with Increased Pump Capacity

with cooling capacities of 1.2 - 2.5 kW

The more powerful VALEGRO recirculating coolers are designed for larger and more complex applications. They feature a precisely adjustable, increased pump pressure up to 3.5 bar.

Model
Add to compare
VALEGRO 1203
Add to compare
VALEGRO 1503
Add to compare
VALEGRO 1803
Add to compare
VALEGRO 2503
Working temperature range (°C) -20 ... 40 -20 ... 40 -20 ... 40 -20 ... 40
Temperature stability (°C) ±0.3 ±0.3 ±0.3 ±0.3
Cooling capacity (kW) 1.2 1.5 1.8 2.5
Pump capacity flow rate (l/min) 15 ... 40 15 ... 40 15 ... 40 15 ... 40
Pump capacity pressure (bar) 0.5 ... 3.5 0.5 ... 3.5 0.5 ... 3.5 0.5 ... 3.5

VALEGRO Recirculating Coolers with Extended Temperature Range and Increased Pump Capacity

with cooling capacities of 1.2 - 2.5 kW

The advanced VALEGRO recirculating coolers meet even the most demanding requirements, featuring an additional heating function and a powerful, pressure-controlled pump. They offer flexible operation and maximum safety in every application.

Model
Add to compare
VALEGRO 1203H
Add to compare
VALEGRO 1503H
Add to compare
VALEGRO 1803H
Add to compare
VALEGRO 2503H
Working temperature range (°C) -20 ... 85 -20 ... 85 -20 ... 85 -20 ... 85
Temperature stability (°C) ±0.2 ±0.2 ±0.2 ±0.2
Cooling capacity (kW) 1.2 1.5 1.8 2.5
Pump capacity flow rate (l/min) 15 ... 40 15 ... 40 15 ... 40 15 ... 40
Pump capacity pressure (bar) 0.5 ... 3.5 0.5 ... 3.5 0.5 ... 3.5 0.5 ... 3.5