PRESTO A30
Temperature Control System / Process System
PRESTO provide large heating and cooling capacities covering a working temperature range from -92 °C to +250 °C. Highly efficient components allow extremely fast compensation of exothermic and endothermic reactions.
Lab users benefit from high flow rates, constant pressure, and a controlled build-up of pump pressure. Changes in the temperature-control liquid’s viscosity are balanced dynamically. Permanent internal monitoring and self-lubricating pumps contribute to the new PRESTO®’s long service life.
A special feature of the new PRESTO is the integrated 5.7’’ industrial touch screen.
All important information is displayed clearly and concisely enhancing ease of use considerably.
The new PRESTO can be operated intuitively with the tip of your finger.
As the new PRESTO operate whisper quiet, you will hardly hear them in your laboratory. Even high room temperatures of up to +40 °C will not make the new PRESTO sweat. Maintenance-free pumps and drives guarantee operational readiness.
Multiple interfaces permit remote control of the PRESTO® across networks and in superordinated control systems. The Design does away with venting slots at the sides. The required installation space is reduced to an absolute minimum.
Your advantages
- For highly precise, external temperature applications
- Rapid heating and cooling
- Fast compensation of exothermic reaction
- Wide working temperature ranges without changing fluids
- Highest performance with small footprint
- Space-saving design optimizes space utilization in your lab
- NEW 5,7” industrial color TFT touch screen
- well-organized view of important information with unmatched, intuitive user friendliness
- Up to 3 user level with password management
- NEW USB (Host und Device)
- NEW Ethernet
- NEW SD-Card slot
- RS232 / optional RS485 / optional Profibus DP
- Stand-by input
- Filling system accessible from the top
- Removable venting grid for simplified removal of dust
Technical Data
| Order No. | 9420300 | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Category | Temperature Control PRESTO | ||||||||||||||||
| Working temperature range (°C) | -30 ... +250 | ||||||||||||||||
| Temperature control | ICC | ||||||||||||||||
| Temperature stability (°C) | ±0.01 ... ±0.05 | ||||||||||||||||
| Setting / display resolution | 0.01 °C | ||||||||||||||||
| Integrated programmer | 8x60 steps | ||||||||||||||||
| Temperature Display | TFT Touchscreen | ||||||||||||||||
| Heating capacity (kW) | 2.3 | ||||||||||||||||
| Cooling capacity (Medium: JULABO Thermal | Ethanol) |
|
||||||||||||||||
| Pump capacity flow rate (l/min) | 25 | ||||||||||||||||
| Pump capacity flow pressure (psi) | 7.25 | ||||||||||||||||
| Pump connections | M24x1.5 | ||||||||||||||||
| Refrigerant stage 1 | R507 | ||||||||||||||||
| Filling volume refrigerant stage 1 (g) | 314 | ||||||||||||||||
| Global Warming Potential for | 3985 | ||||||||||||||||
| Carbon dioxide equivalent stage 1 (t) | 1.251 | ||||||||||||||||
| External Pt100 sensor connection | integrated | ||||||||||||||||
| Digital interfaces |
RS232 SD memory card USB Ethernet Modbus Optional: RS485, Profibus |
||||||||||||||||
| Analog connection input / output | Optional | ||||||||||||||||
| Ambient temperature | 5...40 °C | ||||||||||||||||
| Dimensions W x L x H (inch) | 9.5 x 22.9 x 24 | ||||||||||||||||
| Weight (LBS) | 137 | ||||||||||||||||
| Sound pressure level (distance 1 m) max. (dBA) | 54 | ||||||||||||||||
| Process volume min. (active heat exchanger volume) liters | 2.4 (1.4) | ||||||||||||||||
| Internal usable expansion vol. (liters) | 1.5 | ||||||||||||||||
| Classification according to DIN12876-1 | Classification III (FL) | ||||||||||||||||
| Cooling of compressor | 1-stage Air | ||||||||||||||||
| Power requirement V / Hz / A | 208/60/14 Additional voltage versions available | ||||||||||||||||
| Available voltage versions | 208V/60Hz (-10/+15%) / 15A / Nema N6-20 Plug 230V/50Hz (+/- 10%) / 10A / CH Plug type SEV 1011 230V/50Hz (+/- 10%) / 13A / UK Plug type BS1363A 230V/50Hz (+/- 10%) / 16A / CEE 7/4 Plug type F |
Characteristics
TFT Display for comfortable user guidance, colored display of measurement values, graphs and control options, user-defined views
Touch screen for direct operation via display
Help menus and explanations in plain text for all control options, help messages and warning messages
Language selection for display of control options, notifications and warning messages via touchscreen
Administrator level for customizing instrument settings, user levels with limited permissions for fast and safe defined access, password protection, all levels adjustable
‘Intelligent Cascade Control’, automatic & self optimizing adjustment of PID control parameters, temperature stability ±0.01 °C ... <±0.2 °C
‘Temperature Control Features’, for individual optimization, access to all important control parameters, additional settings for band limit, limits, co-speedfactor etc.
External Pt100 sensor connection for precise measurement and control directly in the external application
‘Absolute Temperature Calibration’ for manual compensation of a temperature difference, 3-point calibration
Easily removable venting grid for quick and easy cleaning
‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures
Proportional cooling control for automatic adjustment of cooling power or temporary switch-off of compressor as needed to save up to 90 % energy in comparison to unregulated cooling machines
Reliable and consistent pump capacity, electronically adjustable pump stages or pressure value, automatic adjustment of pump capacity to viscosity
For the remote control of instruments via Ethernet networks, full access to all functions of the unit via a networkcapable PC
USB connection for data exchange (e.g. service data) or for wireless remote control via WirelessTEMP®
For data exchange (e.g. service data) via SD memory card
RS232/RS485 dual-interface for serial data transmission according to EIA-485 industry standard (2-wire bus technology), upgradable with Profibus DP
Integrated programmer for the execution of time and temperature dependant profiles, 8 temperature profiles with 60 steps max., with real time clock
Efficient components produce only a minimal sound decibel level
All connections as well supply and exhaust air are located at the front or rear, no venting grids on the sides, units can be placed close to each other or the application
Robust temperature control instrument, continuous operation even at ambient temperatures of up to +40 °C
Ergonomic design facilitates moving and positioning by one person
Backlit indicator for selected pump stages and filling volume
Maximum safety for applications, optical and audible signal when limits are exceeded.
Adjustable high temperature cut-off for internal tank and for integrated expansion vessel
Classification III (FL) according to DIN 12876-1
If an error occurs, the integrated Black-Box function permits fast diagnosis by the JULABO service team
Other characteristics
GB version with 2100 W heater capacity / CH version with 1700 W heater capacity
Technical changes without prior notification.
Images may deviate from the original.
We would be pleased to submit a non-binding offer for the selected product or answer all pertinent questions.
click here for quotation request PRESTO A30Search
Contact
JULABO USA Inc.
884 Marcon Boulevard
Allentown, PA 18109
Phone: 610-231-0250
Phone: 800-458-5226
(Toll-Free)
sales@julabo.us
julabo.us
Contact form

