Ultra-Low Refrigerated-Heating Circulators

for working temperatures from -91 °C to +200 °C

JULABO Ultra-Low Refrigerated Circulators for heating and cooling. The units are suitable for external temperature applications with simultaneous operation in the bath tank. The units provide particularly high heating and cooling capacities for rapid heat-up and cool-down times even for large volume, external systems. ‚FP‘ models offer proportional cooling control to ensure energy-saving performance and to reduce heat generation to the environment. Models with the designation ‚W‘ are water-cooled. With handle or castors to allow easy transport. With drain port for conveniently draining the bath fluid. The units offer an improved insulation to prevent ice-formation and have a filling level display. Typical applications: Temperature applications to jacketed reaction vessels, autoclaves, miniplant installations, kilo labs, freezing point determination, calibration at low temperatures, petroleum testing, etc.

Product overview


TopTech
Order No. Model Working temperature
range (°C)
Temperature stability
(°C)
Cooling capacity at 20 °C Heating capacity (kW) Pump capacity flow rate (l/min) Pump pressure (psi) Comparison
9162689 FP89-ME -90 ... +100 ±0.02 1 1.3 11-16 3.3-6.5

HighTech
Order No. Model Working temperature
range (°C)
Temperature stability
(°C)
Cooling capacity at 20 °C Heating capacity (kW) Pump capacity flow rate (l/min) Pump pressure (psi) Comparison
9312689 FP89-HL -90 ... +100 ±0.02 1 1.3 22-26 5.8-10.2
9352751 FP51-SL -51 ... +200 ±0.05 2 3 22-26 5.8-10.2
9352752 FP52-SL -60 ... +100 ±0.05 3 3 22-26 5.8-10.2
9352752N FP52-SL -60 ... +100 ±0.05 3 3 22-26 5.8-10.2
9352752N150 FP52-SL-150C -60 ... +150 ±0.05 3 3 22-26 5.8-10.2
9352753 FPW52-SL -60 ... +100 ±0.05 3 3 22-26 5.8-10.2
9352753N FPW52-SL -60 ... +100 ±0.05 3 3 22-26 5.8-10.2
9352753N150 FPW52-SL-150C -60 ... +150 ±0.05 3 3 22-26 5.8-10.2
9352755 FP55-SL -60 ... +100 ±0.05 5.2 3 22-26 5.8-10.2
9352755N FP55-SL -60 ... +100 ±0.05 5.2 3 22-26 5.8-10.2
9352755N150 FP55-SL-150C -60 ... +150 ±0.05 5.2 3 22-26 5.8-10.2
9352756 FPW55-SL -60 ... +100 ±0.05 5.2 3 22-26 5.8-10.2
9352756N FPW55-SL -60 ... +100 ±0.05 5.2 3 22-26 5.8-10.2
9352756N150 FPW55-SL-150C -60 ... +150 ±0.05 5.2 3 22-26 5.8-10.2
9352790 FP90-SL -90 ... +100 ±0.05 1.8 3 22-26 5.8-10.2
9352790N FP90-SL -90 ... +100 ±0.05 1.8 3 22-26 5.8-10.2
9352790N150 FP90-SL-150C -90 ... +150 ±0.05 1.8 3 22-26 5.8-10.2
9352791 FPW90-SL -90 ... +100 ±0.05 1.8 3 22-26 5.8-10.2
9352791N FPW90-SL -90 ... +100 ±0.05 1.8 3 22-26 5.8-10.2
9352791N150 FPW90-SL-150C -90 ... +150 ±0.05 1.8 3 22-26 5.8-10.2
9352793 FPW91-SL -91 ... +100 ±0.2 4.5 3 22-26 5.8-10.2
9352793N FPW91-SL -91 ... +100 ±0.2 4.5 3 22-26 5.8-10.2
9352795N F95-SL -95 ... +0 ±0.05 3 22-26 5.8-10.2
9352796N FW95-SL -95 ... +0 ±0.05 3 22-26 5.8-10.2