SC2500w SemiChill Compact Recirculating Cooler
5 models for industrial applications, up to 10 kW cooling capacity, customizable
Recirculating Cooler for industrial applications (basic model, additional options for specific requirements available).
The SemiChill series offers powerful recirculating coolers. These units have been especially designed for applications in the semiconductor industry. Five models are available, with cooling capacities from 2.5 to 10 kW (air- or water-cooled). Working temperature ranges from +5 to +35 °C which can optionally be extended from -20 to +130 °C. Also available is a selection of powerful pumps. The units can be modified to provide heater capacities up to 5 kW. Selection between different electronic modules to conform to simple or high demands such as, for example flow rate and conductivity measurement, external temperature control or integration of the coolers via analogue signals, RS232, devicenet or ethernet. A large range of accessories and options including DI filters, microfilters, USB adapters, etc. is available.
Your advantages
- For the most demanding applications
- Space-saving, no lateral ventilation
- Handles and castor make relocation easy
- Industrial grade mains power switch and emergency cut-off
- Pressure gauge
- Liquid level indicator
- Front filling port
- Low noise level
- PID temperature control
- ATC3 3-point calibration
- Early warning system for low liquid level
- Warning and safety functions
- Modular design allows selection between different options
- Water cooled model
Technical Data
| Order No. | 9500026XXP3H0 | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Model series | SemiChill | ||||||||
| Category | Recirculating Coolers | ||||||||
| Working temperature range (°C) |
+5 ... +35 Standard -20 ... +80 Option |
||||||||
| Temperature stability (°C) | ±0.1 | ||||||||
| Setting / display resolution | 0.1 °C | ||||||||
| Integrated programmer | 1x10 steps | ||||||||
| Temperature Display | LED Option | ||||||||
| Heating capacity (kW) |
0 Standard Option |
||||||||
| Cooling capacity (Medium Ethanol) |
|
||||||||
| Pump capacity flow rate (l/min) | 33 | ||||||||
| Pump capacity flow pressure (psi) | 50.8 | ||||||||
| Bath opening / bath depth (W x L / D inch) | |||||||||
| Pump connections | NPT 3/4" | ||||||||
| Barbed fittings diameter (inner dia. / mm) | 3/4" | ||||||||
| Filling volume (liters) | 21 ... 33 | ||||||||
| Refrigerant stage 1 | R452A | ||||||||
| Filling volume refrigerant stage 1 (g) | 750 | ||||||||
| Global Warming Potential for | 2140 | ||||||||
| Carbon dioxide equivalent stage 1 (t) | 1.605 | ||||||||
| External Pt100 sensor connection | integrated | ||||||||
| Digital interfaces |
RS232 Optional Profibus |
||||||||
| Ambient temperature | 5...40 °C | ||||||||
| Dimensions W x L x H (inch) | 19.3 x 24.4 x 41.3 | ||||||||
| Weight (LBS) | 271 | ||||||||
| Sound pressure level (distance 1 m) max. (dBA) | 63 | ||||||||
| Classification according to DIN12876-1 | Classification III (FL) | ||||||||
| Cooling of compressor | Water | ||||||||
| Power requirement V / Hz / A | 230/60/10 Additional voltage versions available |
Characteristics
Large LED temperature display for actual value and setpoint (resolution 0.1 °C)
Ample, easy to read VFD Comfort display for simultaneous display of 3 values, warning functions, high temperature cut-off, pump stages (resolution 0.01 °C)
Backlit indicator for selected pump stages and filling volume on Presto® PLUS, Magnum 91 & Forte HT
Comfortable and simple operation for setpoint adjustment
PID Temperature control with set control parameters, temperature stability ±0.02...±0.2 °C
‘Absolute Temperature Calibration’ for manual compensation of a temperature difference, 3-point calibration
Easily removable venting grid for quick and easy cleaning
‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures
Reliable and consistent pump capacity, electronically adjustable pump stages
External Pt100 sensor connection for precise measurement and control directly in the external application
RS232 interface for PC connection, e.g. for data communication and recording of measured values
Integrated programmer for the execution of time and temperature dependant profiles, 1 temperature profile with 10 steps max., with real time clock
Electronic countdown-timer function for timer-programmed unit shut-down, standby mode after programmed time expires
Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down
Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function
Maximum safety, adjustable high temperature cut-off or dry-running protection, additional display of setpoints permits easy and precise adjustments
Classification III (FL) according to DIN 12876-1
Other characteristics
Important information: this data sheet contains only the basic model. Select your individual SemiChiller according to your specific requirements and the available options. Please contact us: we help you to configure a suitable model for your requirements.
Technical changes without prior notification.
Images may deviate from the original.
We would be pleased to submit a non-binding offer for the selected product or answer all pertinent questions.
click here for quotation request SC2500w SemiChillSearch
Contact
JULABO USA Inc.
884 Marcon Boulevard
Allentown, PA 18109
Phone: 610-231-0250
Phone: 800-458-5226
(Toll-Free)
sales@julabo.us
julabo.us
Contact form
Downloads
- Product data sheet SC2500w SemiChill
- Operating manual SC2500w SemiChill ECO
- Operating manual SC2500w SemiChill PROF
Available voltage versions
Order No.: 9500026XXP3H0
230 V / 50 Hz
208-230 V / 60 Hz