AWC100 Compact Recirculating Cooler
Compact models for applications requiring little cooling performance
Extremely compact Recirculating Cooler to remove small heat loads.
JULABO's Air to Water Recirculating Cooler AWC100 is an extremely compact solution, designed to remove small heat loads from external systems such as from Peltier-elements. The highly competitively priced AWC100 features a compact footprint and is designed specifically for applications where cooling water can be above ambient and where temperature control is secondary. The ventilator speed can be increased by changing the switch for booster cooling on the rear of the unit. Stage 0: normal cooling capacity, virtually noiseless. Stage 1: higher cooling capacity, higher ventilator speed.
Your advantages
- Hassle-free operation
- Small footprint
- Virtually noiseless
- Easy to use
- Economical
Technical Data
| Order No. | 9630100 | ||||
|---|---|---|---|---|---|
| Model series | Cooler | ||||
| Category | Recirculating Coolers | ||||
| Working temperature range (°C) | +20 ... +40 | ||||
| Cooling capacity (Medium Ethanol) |
|
||||
| Pump capacity flow rate (l/min) | 2.9 | ||||
| Pump capacity flow pressure (psi) | 2.9 | ||||
| Pump connections | M10x1 | ||||
| Barbed fittings diameter (inner dia. / mm) | 8 / 10 | ||||
| Filling volume (liters) | 0.9 | ||||
| Ambient temperature | 5...35 °C | ||||
| Dimensions W x L x H (inch) | 8.3 x 14.2 x 12.6 | ||||
| Weight (LBS) | 24 | ||||
| Sound pressure level (distance 1 m) max. (dBA) | 55 | ||||
| Description | Cooling capacity at ambient temperature 20 °C and return line temperature of 30 °C = temperature difference 10 °C = 300 W. For further details please use the product brochure. | ||||
| Included with each unit | 2 barbed fittings for tubing 8 and 10 mm inner dia. (pump connections M10x1 male) | ||||
| Cooling of compressor | Air | ||||
| Power requirement V / Hz / A | 230/50-60/1 Additional voltage versions available |
Other characteristics
Cooling capacity depending on temperature difference between return line and ambient temperature!
Technical changes without prior notification.
Images may deviate from the original.
We would be pleased to submit a non-binding offer for the selected product or answer all pertinent questions.
click here for quotation request AWC100Search
Contact
JULABO USA Inc.
884 Marcon Boulevard
Allentown, PA 18109
Phone: 610-231-0250
Phone: 800-458-5226
(Toll-Free)
sales@julabo.us
julabo.us
Contact form
Available voltage versions
Order No.: 9630100
230 V / 50-60 Hz
115 V / 60 Hz