AWC100 Air-to-water recirculating cooler

for working near ambient temperature extremely compact recirculating cooler to remove small heat loads.

JULABO's Air to water recirculating cooler AWC100 is an extremely compact solution, designed to remove small heat loads from external systems such as from Peltier-elements. The highly competitively priced AWC100 features a compact footprint and is designed specifically for applications where cooling water can be above ambient and where temperature control is secondary.

The ventilator speed can be increased by changing the switch for booster cooling on the rear of the unit. Stage 0: normal cooling capacity, virtually noiseless. Stage 1: higher cooling capacity, higher ventilator speed.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
AWC100
Order number including voltage version 9630100.99
Working temperature range +20 ... +40 °C
Pump capacity flow rate 3.5 l/min
Pump capacity pressure 0.49 bar
Filling volume 0.9 l
Total dimensions
(W × L × H)
20 x 34 x 30 cm
Arrange callback

Product Features

  • Hassle-free operation
  • Connect, switch on and get started
  • Small footprint
  • Economical
  • Very quiet

Technical data for AWC100

Dimensions and volumes
Total dimensions
(W × L × H)
20 x 34 x 30 cm
Filling volume 0.9 l
Weight 9.7 kg
Pump connections M10x1
Barbed fittings inner diameter 8/10 mm
Temperature values
Working temperature range +20 ... +40 °C
Ambient temperature +5 ... +35 °C

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Cooling capacity
Cooling capacity 1 Medium: Ethanol
°C 20 15 10 5
kW 1 0.4 0.32 0.22 0.12
Cooling capacity 2 Medium: Ethanol
°C 20 15 10 5
kW 1 0.55 0.44 0.3 0.18

1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.

Pump capacity flow rate 3.5 l/min
Pump capacity pressure 0.49 bar
Power consumption 0.3 A
Cooling
Cooling of compressor Air
Other
Sound pressure level 55 dB(A)
IP Code
according to IEC 60529
IP 21
Pump type Centrifugal Pump
Available voltage versions
9630100.99 100-230V 50/60Hz (Multiple Plugs (EU / US / GB / CH - Plug))
Included in delivery
2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female)

Accessory for AWC100

Downloads for AWC100

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

AWC100 Benefits

100% Checked.

100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.

Green technology.

Development consistently applied environmentally friendly materials and technologies.

JULABO. Quality.

Highest standards of quality for a long product life.

Quick start.

Individual JULABO consultation and comprehensive manuals at your disposal.

Show all 6 benefits