CF31 Cryo-Compact Circulator
The top class for demanding applications of all types.
Cryo-Compact Circulator for internal and external temperature applications
The new CF series offers compact refrigerated/heating circulators. With small overall dimensions the units can even be placed on a very small surface or within a complex installation. All models offer a heating capacity of 2 kW and classification 3 according to DIN12876-1. The maximum ambient temperature of +40°C as well as a ventilation air cooling allow installing the units very closely side by side with other units or directly under a fume hood. Furthermore all the models feature pump connections for external temperature applications and a bath opening for temperature control of small objects directly in the circulator bath. Wetted parts are made of high quality stainless steel or plastic. The instruments provide a reliable Microprocessor electronics with high temperature stability as well as warning and safety functions.
Your advantages
- Ergonomic design and easy operation
- Small overall dimensions for lowest space requirement
- Splash-proof keypad
- Bright VFD display and interactive LCD dialog display
- Highly precise ICC cascade temperature control
- RS232/RS485 interface for PC connection
- Electronically adjustable pump stages
- External Pt100 sensor connection
- Integrated programmer with 6x60 program steps
- Early warning system for low liquid level
- 3-point calibration
- TCF Temperature Control Features
- Adjustable high temperature cut-off
- Classification 3 according to DIN12876-1
- Pump connections for external temperature applications
- Bath opening for temperature control of small objects in the bath
- Front drain
Technical Data
| Order No. | 9400331 | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Model series | HighTech | ||||||||
| Category | Cryo-Compact Circulators | ||||||||
| Working temperature range (°C) | -30 ... +200 | ||||||||
| Temperature stability (°C) | ±0.02 | ||||||||
| Setting / display resolution | 0.01 °C | ||||||||
| Integrated programmer | 6x60 steps | ||||||||
| Temperature Display | VFD , LCD | ||||||||
| Heating capacity (kW) | 1 | ||||||||
| Cooling capacity (Medium Ethanol) |
|
||||||||
| Pump capacity flow rate (l/min) | 22-26 | ||||||||
| Pump capacity flow pressure (psi) | 5.8-10.2 | ||||||||
| Pump capacity flow suction (psi) | 2.9-5.8 | ||||||||
| Bath opening / bath depth (W x L / D inch) | 6.3 x 1.2 / 5.5 | ||||||||
| Pump connections | M16x1 | ||||||||
| Barbed fittings diameter (inner dia. / mm) | 8 / 12 | ||||||||
| Filling volume (liters) | 3.5 | ||||||||
| Refrigerant stage 1 | R134a | ||||||||
| Filling volume refrigerant stage 1 (g) | 150 | ||||||||
| Global Warming Potential for | 1430 | ||||||||
| Carbon dioxide equivalent stage 1 (t) | 0.215 | ||||||||
| External Pt100 sensor connection | integrated | ||||||||
| Digital interfaces |
RS232 RS485 Optional Profibus |
||||||||
| Ambient temperature | 5...40 °C | ||||||||
| Dimensions W x L x H (inch) | 9.4 x 18.1 x 15.7 | ||||||||
| Weight (LBS) | 79 | ||||||||
| Classification according to DIN12876-1 | Classification III (FL) | ||||||||
| Included with each unit | 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). | ||||||||
| Cooling of compressor | Air | ||||||||
| Power requirement V / Hz / A | 115/60/14 Additional voltage versions available |
Characteristics
Ample, easy to read VFD Comfort display for simultaneous display of 3 values, warning functions, high temperature cut-off, pump stages (resolution 0.01 °C)
Comfortable LCD dialog display for interactive operation with plain text display
Backlit indicator for selected pump stages and filling volume on Presto® PLUS, Magnum 91 & Forte HT
Comfortable, splash-proof keypad for setpoint adjustment, high/low temperatures, timer and shaking frequeny (SW models)
‘Intelligent Cascade Control’, automatic & self optimizing adjustment of PID control parameters, temperature stability ±0.005 °C internal, <±0.05 °C external
‘Temperature Control Features’ for individual optimization, access to all important control parameters, additional settings for band limit, limits, Co-Speedfactor etc.
‘Absolute Temperature Calibration’ for manual compensation of a temperature difference, 3-point calibration
Reliable and consistent pump capacity, electronically adjustable pump stages
External Pt100 sensor connection for precise measurement and control directly in the external application
RS232/RS485 dual-interface for serial data transmission according to EIA-485 industry standard (2-wire bus technology), upgradable with Profibus DP
For the execution of time and temperature dependant profiles, 6 temperature profiles with 60 steps max., with real time clock
Maximum safety for applications, optical and audible alarm, allows user to refill bath fluid before the unit shuts down
Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function
Maximum safety, adjustable high temperature cut-off or dry-running protection, additional display of setpoints permits easy and precise adjustments
Classification III (FL) according to DIN 12876-1
Technical changes without prior notification.
Images may deviate from the original.
We would be pleased to submit a non-binding offer for the selected product or answer all pertinent questions.
click here for quotation request CF31Search
Contact
JULABO USA Inc.
884 Marcon Boulevard
Allentown, PA 18109
Phone: 610-231-0250
Phone: 800-458-5226
(Toll-Free)
sales@julabo.us
julabo.us
Contact form
Available voltage versions
Order No.: 9400331
230 V / 50 Hz
230 V / 60 Hz
115 V / 60 Hz


