Print


F1000 Recirculating Cooler
for simple cooling tasks
JULABO F models require very little space and have very low procurement costs. Recirculating coolers of the F Series are a great way to replace costly tap water and are ideal for basic cooling tasks.
Your advantages
- Environmentally-friendly operation with low energy consumption
- Compact design
- Splash-proof membrane keypad with LED temperature display
- Straightforward filling and draining
- Filling level indicator
- May be used with water, water/glycol, JULABO Thermal G
Technical Data
| Order No. | 9620100 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Model series | F Series | ||||||||||
| Category | Recirculating Coolers | ||||||||||
| Working temperature range (°C) | 0 ... +40 | ||||||||||
| Temperature stability (°C) | ±0.5 | ||||||||||
| Temperature control |
PID temperature control |
||||||||||
| Setting / display resolution | 0.1 °C | ||||||||||
| Temperature Display | LED | ||||||||||
| Cooling capacity (Medium Ethanol) |
|
||||||||||
| Pump capacity flow rate (l/min) | 23 | ||||||||||
| Pump capacity flow pressure (psi) | 14.5 | ||||||||||
| Pump connections | M16x1 | ||||||||||
| Barbed fittings diameter (inner dia. / mm) | 8 / 12 | ||||||||||
| Filling volume (liters) | 7 ... 9.5 | ||||||||||
| Refrigerant stage 1 | R134a | ||||||||||
| Filling volume refrigerant stage 1 (g) | 295 | ||||||||||
| Global Warming Potential for | 1430 | ||||||||||
| Carbon dioxide equivalent stage 1 (t) | 0.422 | ||||||||||
| Ambient temperature | 5...40 °C | ||||||||||
| Dimensions W x L x H (inch) | 14.8 x 19.3 x 25.2 | ||||||||||
| Weight (LBS) | 99 | ||||||||||
| Sound pressure level (distance 1 m) max. (dBA) | 62 | ||||||||||
| Included with each unit | 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 male) | ||||||||||
| Cooling of compressor | Air | ||||||||||
| Power requirement V / Hz / A | 115/60/11 Additional voltage versions available |
Characteristics
Display
Easy to read
Large LED temperature display for actual value and setpoint (resolution 0.1 °C)
Large LED temperature display for actual value and setpoint (resolution 0.1 °C)
Operation
Simple and fast
Convenient 3-key setpoint adjustment (F models)
Convenient 3-key setpoint adjustment (F models)
Temperature Control
Precise
PID Temperature control with set control parameters, temperature stability ±0.02...±0.2 °C
PID Temperature control with set control parameters, temperature stability ±0.02...±0.2 °C
Technical changes without prior notification.
Images may deviate from the original.
We would be pleased to submit a non-binding offer for the selected product or answer all pertinent questions.
click here for quotation request F1000Search
Contact
JULABO USA Inc.
884 Marcon Boulevard
Allentown, PA 18109
Phone: 610-231-0250
Phone: 800-458-5226
(Toll-Free)
sales@julabo.us
julabo.us
Contact form
Available voltage versions
Model: F1000
Order No.: 9620100
230 V / 50 Hz
230 V / 60 Hz
115 V / 60 Hz
Order No.: 9620100
230 V / 50 Hz
230 V / 60 Hz
115 V / 60 Hz

