HT60-M3 High Temperature Circulator
2-zone technique for working temperatures up to 400 °C
JULABO high temperature circulators: The response to present requirements in the market. Peak performance, rapid heating and cooling, fast action in case of exotherm reactions - these are only few of the features of our high temperature circulators. The self-optimizing controller (ICC - Intelligent Cascade Control) ensures high temperature stability. The classic PID control parameters are available at the touch of a button for modification at any time. MULTI-DISPLAY (LED) and interactive LCD display offer convenient operation. The implemented heating automation, strong pump and controlled cooling produce rapid and precise results for temperature applications to +4 00 °C. The instruments are completely sealed. This prevents the release of oil fumes and results in long life time of the heat transfer liquid. Automatic air-purge allows easy filling. Electrical connections and the optional Profibus permit future-oriented automation technology. JULABO high temperature circulators are recommended for applications using jacketed reactors and autoclaves, distillation columns as well as laboratory, miniplant and process-scale applications.
Your advantages
- Working temperature range up to 400 °C
- Self-optimizing ICC temperature controller
- Strong pumping capacity 18 l/min - 1.2 bar max
- Automatic air-purge allows easy filling
- Automated heat-up feature adjusts to external systems
- Bright MULTI-DISPLAY (LED) with display resolution 0.01 °C
- Backlit interactive 4-line LCD display
- On-line communication via built-in RS232 interface
- Stand-by input for external emergency switch-off
- Integrated programmer stores up to 6 profiles (60 sections each)
- Electronic level indication
- ATC function for simple correction of temperature variations
- ATC function allows use as testing instrument according to ISO 9000
- Tap water cooling for temperatures from 40 to 400 °C and rapid cooling
- Cooling capacity up to 15 kW (with tap water 20°C)
Technical Data
| Order No. | 9800063 |
|---|---|
| Category | High Temperature Circulators Forte HT |
| Working temperature range (°C) | +70 ... +400 |
| Temperature stability (°C) | ±0.01-0.1 |
| Setting / display resolution | 0.01 °C |
| Integrated programmer | 6x60 steps |
| Temperature Display | LCD , LED |
| Heating capacity (kW) | 6 |
| Pump capacity flow rate (l/min) | 14-18 |
| Pump capacity flow pressure (psi) | 11.6-17.4 |
| Pump connections | M16x1 |
| Filling volume (liters) | 2 |
| External Pt100 sensor connection | integrated |
| Digital interfaces |
RS232 RS485 Optional Profibus |
| Analog connection input / output | Yes |
| Ambient temperature | 5...40 °C |
| Dimensions W x L x H (inch) | Thermostat: 9.8 x 9.8 x 7.1 |
| Weight (LBS) | 64 |
| Classification according to DIN12876-1 | Classification III (FL) |
| Display for pump pressure and filling volume | Backlit indicator |
| Filling volume expansion vessel liters | 1.6+0.9 |
| Power requirement V / Hz / A | 3x 230/60/14 Additional voltage versions available |
| Dimensions Control unit B x T x H | 25 x 25 x 18 |
Characteristics
Display
Easy to read
Large LED temperature display for actual value and setpoint (resolution 0.1 °C)
Large LED temperature display for actual value and setpoint (resolution 0.1 °C)
Additional plain text information
Comfortable LCD dialog display for interactive operation with plain text display
Comfortable LCD dialog display for interactive operation with plain text display
Pump stage and liquid level
Backlit indicator for selected pump stages and filling volume on Presto® PLUS, Magnum 91 & Forte HT
Backlit indicator for selected pump stages and filling volume on Presto® PLUS, Magnum 91 & Forte HT
Operation
Clearly structured
Comfortable, splash-proof keypad for setpoint adjustment, high/low temperatures, timer and shaking frequeny (SW models)
Comfortable, splash-proof keypad for setpoint adjustment, high/low temperatures, timer and shaking frequeny (SW models)
Temperature Control
For perfect results
‘Intelligent Cascade Control’, automatic & self optimizing adjustment of PID control parameters, temperature stability ±0.005 °C internal, <±0.05 °C external
‘Intelligent Cascade Control’, automatic & self optimizing adjustment of PID control parameters, temperature stability ±0.005 °C internal, <±0.05 °C external
Full control
‘Temperature Control Features’ for individual optimization, access to all important control parameters, additional settings for band limit, limits, Co-Speedfactor etc.
‘Temperature Control Features’ for individual optimization, access to all important control parameters, additional settings for band limit, limits, Co-Speedfactor etc.
High measuring accuracy
‘Absolute Temperature Calibration’ for manual compensation of a temperature difference, 1-point calibration
‘Absolute Temperature Calibration’ for manual compensation of a temperature difference, 1-point calibration
Technical Features
Control from the external application
External Pt100 sensor connection for precise measurement and control directly in the external application
External Pt100 sensor connection for precise measurement and control directly in the external application
Connection compliant to standard
RS232/RS485 dual-interface for serial data transmission according to EIA-485 industry standard (2-wire bus technology), upgradable with Profibus DP
RS232/RS485 dual-interface for serial data transmission according to EIA-485 industry standard (2-wire bus technology), upgradable with Profibus DP
Optimal program control
For the execution of time and temperature dependant profiles, 6 temperature profiles with 60 steps max., with real time clock
For the execution of time and temperature dependant profiles, 6 temperature profiles with 60 steps max., with real time clock
Warning & Safety Functions
Early warning system for high/low temperature limits
Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function
Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function
Enhanced protective functions
Maximum safety, adjustable high temperature cut-off or dry-running protection, additional display of setpoints permits easy and precise adjustments
Maximum safety, adjustable high temperature cut-off or dry-running protection, additional display of setpoints permits easy and precise adjustments
For flammable bath fluids
Classification III (FL) according to DIN 12876-1
Classification III (FL) according to DIN 12876-1
Other characteristics
Permissible cooling water pressure 4.5 bar max, pressure difference between IN and OUT: 2 to 4.5 bar
Technical changes without prior notification.
Images may deviate from the original.
We would be pleased to submit a non-binding offer for the selected product or answer all pertinent questions.
click here for quotation request HT60-M3Search
Contact
JULABO USA Inc.
884 Marcon Boulevard
Allentown, PA 18109
Phone: 610-231-0250
Phone: 800-458-5226
(Toll-Free)
sales@julabo.us
julabo.us
Contact form
Available voltage versions
Model: HT60-M3
Order No.: 9800063
208 V / 3 Ph. / 60 Hz
230 V / 3 Ph. / 60 Hz
Order No.: 9800063
208 V / 3 Ph. / 60 Hz
230 V / 3 Ph. / 60 Hz