DYNEO DD-1000FW Refrigerated / heating circulator

New temperature control technology for demanding applications

Refrigerated circulators of the DYNEO series distinguish themselves with a great price-performance ratio. The instruments offer high heating/cooling capacities for short heat-up and cool-down times. The refrigerated circulators work precisely and reliably even at higher ambient temperatures up to +40 °C. Either in basic research, in material testing or in technical systems – the DYNEO refrigerated circulators offer functional solutions for every requirement and budget.

Optional analog and digital interface

DYNEO thermostats can optionally be equipped with analogue or digital interfaces. To request the options, order number must be extended with .d for the digital and .a for the analog interface (9XXX XXXX.A / 9XXX XXX.D)
DYNEO-Options-Analogue-or-Ditigal-Interface

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
DD-1000FW
Order No. 9021727.02
Working temperature range -50 ... +200 °C
Temperature stability ±0.01 °C
Heating capacity 1 kW
Cooling capacity
Medium: Ethanol
°C 20 10 0 -10 -20 -30 -40
kW* 1
1
0.96
0.73
0.51
0.25
0.11
Refrigerant R449A
Global Warming Potential 1397
Filling volume 190 g
Carbon dioxide equivalent 0.265 t
* Performance specifications measured in accordance with DIN12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.
Pump capacity flow rate 8 ... 27 l/min
Pump capacity flow pressure 1.5 ... 10.2 psi
Usable bath opening
(W x L / D)
7.1 x 5.1 / 5.9 in.
Filling volume 5 ... 7.5 l
Dimensions
(W × L × H)
16.5 x 19.3 x 29.1 in.

Product Features

  • For internal and external applications
  • Optimized cooling coil design saves space in the bath tank
  • Powerful and infinitely adjustable pressure pump
  • Flow rate 27 l/min, pressure 0.7 bar
  • Easy switching between internal and external circulation
  • Large color TFT display, multilingual interface
  • Central rotary knob (controller) simplifies operation
  • Integrated programmer
  • Integrated external Pt100 connection
  • USB connection
  • RS232 interface or analog interfaces (optional)
  • Integrated drain makes emptying liquid easy and safe.
  • Bath cover included with delivery
  • Removable ventilation grid
  • Space-saving cooling coil design provides more usable space in the bath tank
  • For internal and external applications
  • Powerful cooling machines
Dimensions and volumes
Dimensions
(W × L × H)
16.5 x 19.3 x 29.1 in.
Filling volume 5 ... 7.5 l
Weight 112.9 lbs
Pump connections M16x1 male
Barbed fittings inner diameter 8/12 mm
Temperature values
Working temperature range -50 ... +200 °C
Temperature stability ±0.01 °C
Setting the resolution of the temperature display 0.01 °C
Ambient temperature +5 ... +40 °C

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Heating capacity 1 kW
Cooling capacity
Medium: Ethanol
°C 20 10 0 -10 -20 -30 -40
kW* 1
1
0.96
0.73
0.51
0.25
0.11
Refrigerant R449A
Global Warming Potential 1397
Filling volume 190 g
Carbon dioxide equivalent 0.265 t
* Performance specifications measured in accordance with DIN12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.
Pump capacity flow rate 8 ... 27 l/min
Pump capacity flow pressure 1.5 ... 10.2 psi
Viscosity max. 50 cST
Power 16 A
Bath
Bath tank Stainless steel
Bath cover integrated
Usable bath opening
(W x L / D)
7.1 x 5.1 / 5.9 in.
Cooling
Cooling of compressor 1-stage Water
Cooling water pressure max. 87 psi
Cooling water difference pressure 4.4 psi
Cooling water temperature max. 30 °C
1.0Cooling water consumption 1.1 l/min
Other
Classification
according to DIN12876-1
Classification III (FL)
Pump function Pressure Pump
Pump type Immersion Pump
Electronics
Digital interface RS232 optional / USB / Alarm output optional / Reg/Eprog optional / Standby-Input optional
External pt100 sensor connection integrated
Integrated programmer 8x60 steps
Temperature control PID3
Absolute temperature calibration 3 Point Calibration
Temperature displayTemperature display 3.5" TFT Display
Temperature settingTemperature setting Shaft Encoder
Electronic Timer
hr:min
00:00 ... 99:59
Available voltage versions
9021727.02 115V/60Hz (Nema N5-20 Plug) (R449A)
9021727.04 230V/50-60Hz (UK Plug Type BS1363A) (R449A)
9021727.05 230V/50-60Hz (CH Plug Type SEV 1011) (R449A)
9021727.33 230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R449A)
9021727.33.chn 230V/50-60Hz (CN Plug) (R449A)
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)

Accessory for DYNEO DD-1000FW

We would also be happy to send you our printed catalogs and brochures by post.



Benefits

  • TCF
    Quick support
    If an error occurs, the integrated Black-Box function permits fast diagnosis by the JULABO service team
  • easy-to-handle
    Handle with ease.
    Makes day-to-day work easy. Comfortably move your CORIO around by using the ergonomic handles (front and rear).
  • PID2
    Highly precise
    PID Temperature control with drift compensation and adjustable control parameters, temperature stability ±0.01...±0.02 °C
  • dyneo-controller
    Turn. Push. Go.
    Easy operation of all parameters using the central controller.