FT402 FT Immersion Cooler
with immersion probe for rapid cooling of liquids
JULABO Immersion Coolers are primarily used for counter-cooling when connected to a heating circulator, or for rapidly cooling fluids down to low temperatures. Take advantage of the space-saving design.
JULABO Immersion Coolers represent an economical alternative to conventional tap water cooling. The easy-to-use units are suitable for a variety of cooling applications.
Request a quoteOrder No. | 9 650 842.05 | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -40 ... +30 °C | |||||||||||||
Temperature stability | ±0.5 °C | |||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||
|
||||||||||||||
Dimensions (W × L × H) |
7.9 x 11.8 x 16.9 in. |
Order No. | 9 650 842.02 | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -40 ... +30 °C | |||||||||||||
Temperature stability | ±0.5 °C | |||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||
|
||||||||||||||
Dimensions (W × L × H) |
7.9 x 11.8 x 16.9 in. |
Order No. | 9 650 842.03 | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -40 ... +30 °C | |||||||||||||
Temperature stability | ±0.5 °C | |||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||
|
||||||||||||||
Dimensions (W × L × H) |
7.9 x 11.8 x 16.9 in. |
Order No. | 9 650 842.04 | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -40 ... +30 °C | |||||||||||||
Temperature stability | ±0.5 °C | |||||||||||||
Cooling capacity (Medium: Ethanol) |
|
|
||||||||||||
Cooling capacity
(Medium: Ethanol) |
||||||||||||||
|
||||||||||||||
Dimensions (W × L × H) |
7.9 x 11.8 x 16.9 in. |
Product Features
- Rapid cooling of liquids down to low temperatures
- Counter-cooling of liquids in combination with heating circulators
- Preventing the use of precious tap water for cooling
- Compact design, small footprint
- Ease of operation
- Dry ice substitution
Dimensions (W × L × H) |
7.9 x 11.8 x 16.9 in. |
---|---|
Weight | 59.5 lbs |
Working temperature range | -40 ... +30 °C |
---|---|
Temperature stability | ±0.5 °C |
Temperature display resolution | 0.1 °C |
Ambient temperature | 5 ... 35 °C |
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||
|
|||||||||||||||
Refrigerant stage 1 |
Refrigerant | R452A | |||||||||||||
Global Warming Potential for R452A | 2140 | ||||||||||||||
Filling volume | 210 g | ||||||||||||||
Carbon dioxide equivalent | 0.449 t |
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||
|
|||||||||||||||
Refrigerant stage 1 |
Refrigerant | R449A | |||||||||||||
Global Warming Potential for R449A | 1397 | ||||||||||||||
Filling volume | 112 g | ||||||||||||||
Carbon dioxide equivalent | 0.156 t |
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||
|
|||||||||||||||
Refrigerant stage 1 |
Refrigerant | R452A | |||||||||||||
Global Warming Potential for R452A | 2140 | ||||||||||||||
Filling volume | 210 g | ||||||||||||||
Carbon dioxide equivalent | 0.449 t |
Cooling capacity (Medium: Ethanol) |
|
|
|||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
(Medium: Ethanol) |
|||||||||||||||
|
|||||||||||||||
Refrigerant stage 1 |
Refrigerant | R452A | |||||||||||||
Global Warming Potential for R452A | 2140 | ||||||||||||||
Filling volume | 210 g | ||||||||||||||
Carbon dioxide equivalent | 0.449 t |
Cooling of compressor | 1-stage Air |
---|
Sound pressure level | 61 dbA |
---|---|
IP Code according to IEC 60529 |
IP 21 |
External pt100 sensor connection | integrated |
---|---|
Temperature control | PID1 |
Temperature displayTemperature display | LED |
Temperature settingTemperature setting | Keypad |
Immersion probe type | inflexible |
---|---|
Dimensions immersion probe cylindrical (L x ⌀) |
4.7 x 2 in. |
230V/50Hz CH Plug Type SEV 1011 | 9650842.05 |
---|---|
115V/60Hz Nema N5-15 Plug | 9650842.02 |
230V/50Hz Schuko Plug - CEE 7/4 Plug Type F | 9650842.03 |
230V/50Hz UK Plug Type BS1363A | 9650842.04 |
Accessory for FT402
Benefits
-
JULABO. Quality.
Highest standards of quality for a long product life. -
Green technology.
Development consistently applied environmentally friendly materials and technologies. -
Satisfied customers.
11 subsidiaries and more than 100 partners worldwide guarantee fast and qualified JULABO support. -
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.