FLW20006
Order No. 9676200.07
Working temperature range -25 ... +40 °C
Temperature stability ±0.5 °C
Cooling capacity
Medium: Ethanol
°C 20 10 0 -10 -20
kW 1 20 17 13 9 4
Refrigerant R452A
Global Warming Potential 2140
Filling weight 2750 g
Carbon dioxide equivalent 5.885 t

1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.

Pump capacity flow rate 80 l/min
Pump capacity flow pressure 0.8 ... 6 bar
Filling volume 15 ... 37 l
Dimensions
(W × L × H)
95 x 115 x 161 cm
Arrange callback

Product Features

  • Ergonomic design and easy operation
  • Splash-proof keypad
  • Large, bright LED display
  • Permissible temperature in return line +80°C
  • Easy filling from the top with hinged protective lid
  • Low liquid level protection with optical and audible alarm signal
  • Integrated stainless steel bath tanks
  • Front drain
  • No side vents, instruments can be placed right next to other equipment
  • RS232 interface for PC connection
  • IP class according to IEC 60529: 21
  • Alarm output, potential-free change-over contact (max. 30 VA)
  • Pressure Indicator

Technical data for FLW20006

Dimensions and volumes
Dimensions
(W × L × H)
95 x 115 x 161 cm
Filling volume 15 ... 37 l
Weight 341 kg
Pump connections G1¼" male
Cooling Water Connection G¾ in
Barbed fittings inner diameter 1"
Temperature values
Working temperature range -25 ... +40 °C
Temperature stability ±0.5 °C
Setting the resolution of the temperature display 0.1 °C
Setting the resolution of the temperature display 0.1 °C
Ambient temperature +5 ... +40 °C
Return flow temperature max. 80 °C

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Cooling capacity
Medium: Ethanol
°C 20 10 0 -10 -20
kW 1 20 17 13 9 4
Refrigerant R452A
Global Warming Potential 2140
Filling weight 2750 g
Carbon dioxide equivalent 5.885 t

1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.

Pump capacity flow rate 80 l/min
Pump capacity flow pressure 0.8 ... 6 bar
Power consumption 18 A
Bath
Bath tank Stainless steel
Cooling
Cooling of compressor 1-stage Water
Cooling water pressure max. 6 bar

Recommended cooling water properties
to provide full cooling capacity according to catalog values
Cooling water temperature range 15 °C
Cooling water difference pressure 2 bar
Cooling water consumption 24 l/min
Other
Sound pressure level 69 dbA
Classification
according to DIN12876-1
Classification I (NFL)
IP Code
according to IEC 60529
IP 21
Pump type Centrifugal Pump
Electronics
Interfaces Alarm output / RS232 / Stakei
Temperature control PID1
Temperature display LED
Temperature setting Keypad
Available voltage versions
9676200.16 230V/3PPE/60Hz (Without Plug) (R449A)
9676200.07 400V/3PNPE/50Hz (Plug 32A CEE) (R452A)
Included in delivery
2 each barbed fittings for tubing 1" inner dia (pumpconnections G1 1/4" male).

Accessory for FLW20006

Downloads for FLW20006

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

FLW20006 Benefits

100% Checked.

100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.

Green technology.

Development consistently applied environmentally friendly materials and technologies.

JULABO. Quality.

Highest standards of quality for a long product life.

Quick start.

Individual JULABO consultation and comprehensive manuals at your disposal.

Show all 8 benefits