CF30 Cryo-compact circulator
The basis for routine work and standard tasks in the laboratory
The cryo-compact circulators of the CF series provide powerful cooling and heating capabilities in a space-saving, compact design. The instruments feature 2 kW heating capacity and classification III according to DIN 12876-1. The cryo-compact circulators have pump connections for external temperature control applications and a bath opening for tem-perature control of small objects.
Performance data depends on the mains voltage in the country of use. Please select:
| Order number including voltage version | 9400330.04 |
|---|---|
| Working temperature range | -30 ... 150 °C |
| Temperature stability | ±0.03 °C |
| Heating capacity | 2 kW |
| Pump capacity flow rate | 15 l/min |
| Pump capacity pressure | 0.35 bar |
|
Usable bath opening (W x L / D) |
16 x 3 / 14 cm |
| Filling volume | 2 ... 3.5 l |
|
Total dimensions
(W × L × H) |
24 x 46 x 40 cm |
Product Features
- Ergonomic design and easy operation
- Small overall dimensions for lowest space requirement
- Splash-proof keypad
- Large, bright LED display
- Precise PID temperature control
- RS232 interface for PC connection
- Adjustable high temperature cut-out, visible via display
- Pump connections for external temperature applications
- Bath opening for temperature control of small objects in the bath
- Front drain
- Extra bright displays, easy to read from a distance
- Precise temperature control
- Unique early warning system for low liquid level
- ATC3 3-Point-Calibration
- Class III (FL) according to DIN 12876-1
Technical data for CF30
|
Total dimensions (W × L × H) |
24 x 46 x 40 cm |
|---|---|
| Filling volume | 2 ... 3.5 l |
| Weight | 35 kg |
| Pump connections | M16x1 male |
| Barbed fittings inner diameter | 8/12 mm |
| Working temperature range | -30 ... 150 °C |
|---|---|
| Temperature stability | ±0.03 °C |
| Temperature display resolution | 0.1 °C |
| Ambient temperature | +5 ... +40 °C |
Performance data depends on the mains voltage in the country of use. Please select:
| Heating capacity | 2 kW | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
||||||||||||||||||
| Pump capacity flow rate | 15 l/min | |||||||||||||||||
| Pump capacity pressure | 0.35 bar | |||||||||||||||||
| Viscosity max. | 30 cSt | |||||||||||||||||
| Power consumption | 10 A | |||||||||||||||||
| Bath tank | Stainless steel |
|---|---|
| Bath cover | integrated |
|
Usable bath opening (W x L / D) |
16 x 3 / 14 cm |
| Cooling of compressor | 1-stage Air |
|---|
| Classification according to DIN12876-1 |
Classification III (FL) |
|---|---|
| IP Code according to IEC 60529 |
IP 21 |
| Pump type | Immersion Pump |
| Interfaces | RS232 |
|---|---|
| Temperature control | PID1 |
| Temperature display | LED |
| 9400330.13 | 230V 60Hz (Nema N6-20 Plug) (R134a) |
|---|---|
| 9400330.02 | 115V 60Hz (Nema N5-20 Plug) (R134a) |
| 9400330.03 | 230V 50Hz (Schuko Plug - CEE 7/4 Plug Type F) (R134a) |
| 9400330.04 | 230V 50Hz (UK Plug Type BS1363A) (R134a) |
| 2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for CF30
Downloads for CF30
We would also be happy to send you our printed catalogs and brochures by post.
Request brochureCF30 Benefits
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
Green technology.
Development consistently applied environmentally friendly materials and technologies.
JULABO. Quality.
Highest standards of quality for a long product life.
Quick start.
Individual JULABO consultation and comprehensive manuals at your disposal.
Related Products
Products with similar properties