PRESTO W40 Process system

Compact process systems down to -45 °C

JULABO's water-cooled PRESTO W40 process system combines high performance and a very compact design with all the advantages of the PRESTO series for a working temperature range from -40 °C to +250 °C.

The highly dynamic temperature control systems PRESTO are designed for high-precision temperature control for a wide range of applications such as reactor vessels or material stress tests. Moreover, by using efficient components, the process systems can compensate exothermic and endothermic reactions exceptionally fast. Permanent internal monitoring and self-lubricating pumps ensure a long life-time. In addition, numerous interfaces offer many remote control possibilities across networks or for integration into higher-level control systems.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
W40
Order number including voltage version 9421401.04
Working temperature range -40 ... 250 °C
Temperature stability ±0.01 ... ±0.05 °C
Heating capacity 1.8 kW
Pump capacity flow rate 0 ... 40 l/min
Pump capacity pressure 0.1 ... 1.7 bar
Total dimensions
(W × L × H)
33 x 59 x 67 cm
Arrange callback

Product Features

  • Second external Pt100 sensor connection (accessory)

Technical data for PRESTO W40

Dimensions and volumes
Total dimensions
(W × L × H)
33 x 59 x 67 cm
Internal usable expansion volume 2.7 l
Minimal process volume 3.5 l
Active heat exchanger volume 1.7 l
Weight 78 kg
Pump connections M24x1.5 male
Cooling Water Connection G¾ in
Temperature values
Working temperature range -40 ... 250 °C
Temperature stability ±0.01 ... ±0.05 °C
Setting the resolution of the temperature display 0.01 °C
Temperature display resolution 0.01 °C
Ambient temperature +5 ... +40 °C

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Heating capacity 1.8 kW
Cooling capacity
Medium: Ethanol
°C 20 0 -10 -20 -30 -40
kW 1 1.2 1 0.8 0.55 0.3 0.07
Refrigerant R449A
Global Warming Potential 1397
Filling weight 380 g
Carbon dioxide equivalent 0.53086 t

1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.
Cooling capacity 1 = capacity at minimum pump level, cooling capacity 2 = capacity at maximum pump level

Pump capacity flow rate 0 ... 40 l/min
Pump capacity pressure 0.1 ... 1.7 bar
Viscosity max. 50 cSt
Power consumption 13 A
Cooling
Cooling of compressor 1-stage Water
Cooling water pressure max. 6 bar
Max. heat dissipated by unit into cooling water 2 kW

Recommended cooling water properties
to provide full cooling capacity according to catalog values
Cooling water temperature range 10 ... 15 °C
Cooling water difference pressure 1.5 ... 6 bar
Cooling water consumption 1 1 l/min

1 Cooling water consumption may vary outside recommended cooling water properties.


Permissible cooling water properties
Cooling water temperature range 5 ... 35 °C
Cooling water difference pressure 2 0.5 ... 6 bar

2 At cooling water temperatures of 25 °C and higher, the minimum differential pressure is 1 bar.

Other
Sound pressure level 53 dB(A)
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Pump type Centrifugal Pump (Magnetically coupled)
Electronics
Interfaces Alarm output / Ethernet / Modbus TCP/IP / Profibus optional / REG/EPROG optional / RS232 / RS485 optional / SD memory card / Standby-Input optional / USB
External pt100 sensor connection integrated
2nd external Pt100 sensor connection accessory
Integrated programmer 8x60 steps
Temperature control ICC
Absolute temperature calibration 3 Point Calibration
Temperature display 5.7" TFT Touchscreen
Temperature setting Touchscreen
Available voltage versions
9421401.33 200-230V 50/60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R507)
9421401.04 230V 50/60Hz (UK Plug Type BS1363A) (R449A)
9421401.05 230V 50/60Hz (CH Plug Type T12 / 10A) (R449A)
9421401.14 208V 60Hz (Nema N6-20 Plug) (R449A)
9421401.05.S3536 230V 50/60Hz (CH Plug Type T23 / 16A) (R449A)
9421401.33.507.S3537 230V 50/60Hz (CH Plug Type T23 / 16A) (R507)
Contact expert

Cool-down time

Medium: Thermal HL

Heat-up time

Medium: Thermal HL

Pump capacity

Accessory for PRESTO W40

Downloads for PRESTO W40

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

PRESTO W40 Benefits

Intelligent temperature control.

Intelligent cascade control - automatic and self-optimizing adaptation of the PID control parameters with external stability of +/- 0.05 °C.

Full control

‘Temperature Control Features’, for individual optimization, access to all important control parameters, additional settings for band limit, limits, co-speedfactor etc.

Control of the external application

External Pt100 sensor connection for precise measurement and control directly in the external application

Highest measuring accuracy

‘Absolute Temperature Calibration’ for manual compensation of a temperature difference, 3-point calibration

Show all 21 benefits