PRESTO W40 Process system
Compact process systems down to -45 °C
JULABO's water-cooled PRESTO W40 process system combines high performance and a very compact design with all the advantages of the PRESTO series for a working temperature range from -40 °C to +250 °C.
The highly dynamic temperature control systems PRESTO are designed for high-precision temperature control for a wide range of applications such as reactor vessels or material stress tests. Moreover, by using efficient components, the process systems can compensate exothermic and endothermic reactions exceptionally fast. Permanent internal monitoring and self-lubricating pumps ensure a long life-time. In addition, numerous interfaces offer many remote control possibilities across networks or for integration into higher-level control systems.
Performance data depends on the mains voltage in the country of use. Please select:
| Order number including voltage version | see refrigerant variants |
|---|---|
| Working temperature range | -40 ... 250 °C |
| Temperature stability | ±0.01 ... ±0.05 °C |
| Heating capacity | 2.7 kW |
| Pump capacity flow rate | 0 ... 40 l/min |
| Pump capacity pressure | 0.1 ... 1.7 bar |
|
Total dimensions
(W × L × H) |
33 x 59 x 67 cm |
Product Features
- Heating capacity up to 2.7 kW
- Temperature stability ±0.01 °C ... ±0.05 °C
- Alarm output
- Built-in 5.7’’ industrial color touchscreen
- External Pt100 sensor connection
- Connections for USB, Ethernet, RS232, and Alarm output
- Analog connections, RS485, Profibus DP (accessory)
- Second external Pt100 sensor connection (accessory)
- Pump pressure up to 1.7 bar, max. flow rate 40 l/min
- RS232
- RS485 (Accessory)
- Profibus DP (Accessory)
- Cooling capacity up to 1.2 kW
Technical data for PRESTO W40
|
Total dimensions (W × L × H) |
33 x 59 x 67 cm |
|---|---|
| Internal usable expansion volume | 2.7 l |
| Minimal process volume | 3.5 l |
| Active heat exchanger volume | 1.7 l |
| Weight | 78 kg |
| Pump connections | M24x1.5 male |
| Cooling Water Connection | G¾ in |
| Working temperature range | -40 ... 250 °C |
|---|---|
| Temperature stability | ±0.01 ... ±0.05 °C |
| Setting the resolution of the temperature display | 0.01 °C |
| Temperature display resolution | 0.01 °C |
| Ambient temperature | +5 ... +40 °C |
Performance data depends on the mains voltage in the country of use. Please select:
| Heating capacity | 2.7 kW | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Pump capacity flow rate | 0 ... 40 l/min | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Pump capacity pressure | 0.1 ... 1.7 bar | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Viscosity max. | 50 cSt | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Power consumption | 16 A | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Cooling of compressor | 1-stage Water |
|---|---|
| Cooling water pressure max. | 6 bar |
| Max. heat dissipated by unit into cooling water | 2 kW |
| to provide full cooling capacity according to catalog values | |
| Cooling water temperature range | 10 ... 15 °C |
|---|---|
| Cooling water difference pressure | 1.5 ... 6 bar |
| Cooling water consumption 1 | 1 l/min |
|
1 Cooling water consumption may vary outside recommended cooling water properties. |
|
| Cooling water temperature range | 5 ... 35 °C |
|---|---|
| Cooling water difference pressure 2 | 0.5 ... 6 bar |
|
2 At cooling water temperatures of 25 °C and higher, the minimum differential pressure is 1 bar. |
|
| Sound pressure level | 53 dB(A) |
|---|---|
| Classification according to DIN12876-1 |
Classification III (FL) |
| IP Code according to IEC 60529 |
IP 21 |
| Pump type | Centrifugal Pump (Magnetically coupled) |
| Interfaces | Alarm output / Ethernet / Modbus TCP/IP / Profibus optional / REG/EPROG optional / RS232 / RS485 optional / SD memory card / Standby-Input optional / USB |
|---|---|
| External pt100 sensor connection | integrated |
| 2nd external Pt100 sensor connection | accessory |
| Integrated programmer | 8x60 steps |
| Temperature control | ICC |
| Absolute temperature calibration | 3 Point Calibration |
| Temperature display | 5.7" TFT Touchscreen |
| Temperature setting | Touchscreen |
| 9421401.33 | 200-230V 50/60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R507) |
|---|---|
| 9421401.04 | 230V 50/60Hz (UK Plug Type BS1363A) (R449A) |
| 9421401.05 | 230V 50/60Hz (CH Plug Type T12 / 10A) (R449A) |
| 9421401.14 | 208V 60Hz (Nema N6-20 Plug) (R449A) |
| 9421401.05.S3536 | 230V 50/60Hz (CH Plug Type T23 / 16A) (R449A) |
| 9421401.33.507.S3537 | 230V 50/60Hz (CH Plug Type T23 / 16A) (R507) |
Accessory for PRESTO W40
Downloads for PRESTO W40
We would also be happy to send you our printed catalogs and brochures by post.
Request brochurePRESTO W40 Benefits
Intelligent temperature control.
Intelligent cascade control - automatic and self-optimizing adaptation of the PID control parameters with external stability of +/- 0.05 °C.
Full control
‘Temperature Control Features’, for individual optimization, access to all important control parameters, additional settings for band limit, limits, co-speedfactor etc.
Control of the external application
External Pt100 sensor connection for precise measurement and control directly in the external application
Highest measuring accuracy
‘Absolute Temperature Calibration’ for manual compensation of a temperature difference, 3-point calibration