IC50 Immersion cooler new

Modern immersion coolers with natural refrigerant for rapid cool-down of fluids

JULABO immersion coolers are mainly used for counter-cooling in conjunction with heating circulators or for rapid cooling of fluids to low temperatures. The modern IC Series works with natural, climate-friendly refrigerants.

The IC50 immersion cooler was developed with a focus on high user-friendliness. The removable venting grid, which can be removed without tools, facilitates regular cleaning for maximum performance over the unit's entire life-time. The magnetic probe holder enables flexible and stable attachment of the probe to magnetic surfaces, ensuring hassle-free positioning for various applications.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
IC50
Order number including voltage version 9651050.30003827
Working temperature range 1 -50 ... 100 °C
Total dimensions
(W × L × H)
9.1 x 17.3 x 15.7 in.
Body dimensions
(W × L × H)
9.1 x 17.3 x 14.2 in.

1 JULABO immersion coolers are especially suitable for cooling applications and therefore cannot be used as heaters. The specification of the working temperature range above the ambient temperature corresponds to the maximum permissible temperature in the application for which the immersion cooler is approved. The lowest temperature of the working temperature range corresponds to the minimum temperature that the probe reaches at its surface.

Arrange callback

Product Features

  • Rapid cooling of liquids down to low temperatures
  • Counter-cooling of fluids in combination with heating circulators
  • Water-Saving & Environmentally Friendly: An Ecological and Resource-Conserving Alternative to Continuous Tap Water Cooling
  • Dry Ice Substitute: A Sustainable and Economic Alternative to Dry Ice
  • Sturdy cases with handles
  • High-quality stainless steel immersion probe

Technical data for IC50

Dimensions and volumes
Total dimensions
(W × L × H)
9.1 x 17.3 x 15.7 in.
Body dimensions
(W × L × H)
9.1 x 17.3 x 14.2 in.
Weight 47.4 lbs
Temperature values
Working temperature range 1 -50 ... 100 °C
Ambient temperature +5 ... +40 °C

1 JULABO immersion coolers are especially suitable for cooling applications and therefore cannot be used as heaters. The specification of the working temperature range above the ambient temperature corresponds to the maximum permissible temperature in the application for which the immersion cooler is approved. The lowest temperature of the working temperature range corresponds to the minimum temperature that the probe reaches at its surface.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Cooling capacity
Medium: Ethanol
°C 20 0 -20 -40
kW 2 0.45 0.32 0.16 0.04
Refrigerant R1270
Global Warming Potential 2
Filling weight 41 g
Carbon dioxide equivalent 8.2E-5 t

2 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.

Power consumption 4 A
Cooling
Cooling of compressor 1-stage Air
Other
Sound pressure level 55 dB(A)
Classification
according to DIN12876-1
Classification I (NFL)
IP Code
according to IEC 60529
IP 21
Electronics
External pt100 sensor connection not available
Immersion cooler
Dimensions probe tube
(L x Ø)
47.2 in.
Immersion probe type inflexible
Dimensions immersion probe cylindrical
(L x Ø)
3.9 x 2 in.
Available voltage versions
9651050.30003826 115V 60Hz (Nema N5-15 Plug) (R1270)
9651050.30003827 200-230V 50/60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R1270)
9651050.30003829 230V 50/60Hz (CH Plug Type T12 / 10A) (R1270)
9651050.30003828 230V 50Hz (UK Plug Type BS1363A) (R1270)

Accessory for IC50

Downloads for IC50

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

Maintenance notice

On Friday, 7 August 2026, we will be unavailable by phone and email from 2:30 PM for approximately 45 minutes. We'll be back from around 3:15 PM (CEST).