PRESTO W58x Process system

The most powerful, single-stage, highly dynamic temperature control systems

The water-cooled PRESTO W58x is able to quickly and efficiently control the temperature in applications requiring a great deal of power. This model features has an impressive cooling capacity of 33 kW at 20°C, thus ensuring that it maintains large power reserves over its entire working temperature range, especially at temperatures around -30°C to -40°C, which are often necessary for automotive testing.

The PRESTO W58x process system is equipped with a gear pump. As a result, bath fluids with a high viscosity, such as water-glycol mixtures at low temperatures of up to -45 °C, can also be used .

The magnetically coupled pump allows the user to optimally adjust pump capacity to suit the application, even over large distances and height differences, as well as for pressure-sensitive applications. Use of the latest thermodynamic technologies means that the cooling capacity is automatically adjusted to the current power requirements. Combined with further optimizations, the PRESTO W58x is both incredibly economical and energy-efficient.

Water-glycol up to +150 °C

Connection of an expansion kit ( accessorie) allows pressurized temperature control with water-glycol up to a working temperature of +150 °C.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
W58x
Order number including voltage version 9421583.S1.17
Working temperature range -50 ... 250 °C
Temperature stability ±0.05 ... ±0.1 °C
Heating capacity 27 kW
Pump capacity flow rate 0 ... 70 l/min
Pump capacity pressure 1.5 ... 79.8 psi
Total dimensions
(W × L × H)
27.6 x 42.5 x 68.5 in.
Arrange callback

Product Features

  • Second external Pt100 sensor connection (accessory)

Technical data for PRESTO W58x

Dimensions and volumes
Total dimensions
(W × L × H)
27.6 x 42.5 x 68.5 in.
Internal usable expansion volume 17.5 l
Minimal process volume 13 l
Active heat exchanger volume 12 l
Weight 1071.4 lbs
Pump connections M38x1.5 male
Cooling Water Connection G¾ in.
Temperature values
Working temperature range -50 ... 250 °C
Temperature stability ±0.05 ... ±0.1 °C
Setting the resolution of the temperature display 0.01 °C
Temperature display resolution 0.01 °C
Ambient temperature +5 ... +40 °C

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Heating capacity 27 kW
Cooling capacity
Cooling capacity 1 Medium: Ethanol
°C 20 0 -10 -20 -30 -40 -50
kW 1 33 32 28 19 12 7 1.4
Cooling capacity 2 Medium: Water Glycol 40:60
°C 20 0 -10 -20 -30 -40
kW 1 33 32 25 16 10 5.5
Refrigerant R449A
Global Warming Potential 1397
Filling weight 2550 g
Carbon dioxide equivalent 3.56235 t

1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.

Pump capacity flow rate 0 ... 70 l/min
Pump capacity pressure 1.5 ... 79.8 psi
Viscosity max. 280 cSt
Power consumption 47 A
Cooling
Cooling of compressor 1-stage Water
Cooling water pressure max. 87 psi
Max. heat dissipated by unit into cooling water 56 kW

Recommended cooling water properties
to provide full cooling capacity according to catalog values
Cooling water temperature range 10 ... 15 °C
Cooling water difference pressure 43.5 ... 87 psi
Cooling water consumption 1 21 ... 28 l/min

1 Cooling water consumption may vary outside recommended cooling water properties.


Permissible cooling water properties
Cooling water temperature range 5 ... 35 °C
Cooling water difference pressure 2 21.8 ... 87 psi

2 At cooling water temperatures of 25 °C and higher, the minimum differential pressure is 1 bar.

Other
Sound pressure level 72 dB(A)
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 20
Pump type Gear Pump
Electronics
Interfaces Alarm output / Ethernet / Modbus TCP/IP / Profibus optional / REG/EPROG optional / RS232 / RS485 optional / SD memory card / Standby-Input optional / USB
External pt100 sensor connection integrated
2nd external Pt100 sensor connection accessory
Integrated programmer 8x60 steps
Temperature control ICC
Absolute temperature calibration 3 Point Calibration
Temperature display 5.7" TFT Touchscreen
Temperature setting Touchscreen
Available voltage versions
9421583.S1.07 400V 3PPE 50Hz (Plug 63A CEE) (R449A)
9421583.S1.17 480V 3P(N)PE 60Hz (Without Plug) (R449A)

Accessory for PRESTO W58x

Downloads for PRESTO W58x

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure