Performance data depends on the mains voltage in the country of use. Please select:
Country of use | Mains voltage | Plug | JULABO voltage version code
CORIO C-BT5
| Order number including voltage version |
9011305.22 |
|
Working temperature range
1
|
20 ... 90 °C |
|
Temperature stability
|
±0.03 °C
|
|
Heating capacity
|
1 kW |
Usable bath opening (W x L / D) |
5.9 x 5.9 / 5.9 in.
|
|
Filling volume
|
3.5 ... 5 l
|
Total dimensions
(W × L × H) |
9.1 x 15 x 15 in.
|
|
1 For applications near or below ambient temperature: use a cooling coil or JULABO immersion cooler.
|
- Bright, white, easy to read display
- Very quiet
- for internal applications
- Easy operation
- Integrated drain screw (except B5)
- Bath fluid: water
Technical data for CORIO C-BT5
Dimensions and volumes
Total dimensions (W × L × H) |
9.1 x 15 x 15 in.
|
|
Filling volume
|
3.5 ... 5 l
|
|
Weight
|
10.6 lbs
|
Temperature values
|
Working temperature range
1
|
20 ... 90 °C |
|
Temperature stability
|
±0.03 °C
|
|
Setting the resolution of the temperature display
|
0.1 °C
|
|
Temperature display resolution
|
0.01 ... 0.1 °C
|
|
Ambient temperature
|
+5 ... +40 °C
|
|
1 For applications near or below ambient temperature: use a cooling coil or JULABO immersion cooler.
|
Performance data depends on the mains voltage in the country of use. Please select:
Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
|
Heating capacity
|
1 kW |
|
Viscosity max.
|
1 cSt |
|
Circulation capacity flow rate
|
6 l/min
|
|
Circulation capacity pressure
|
1.5 psi
|
| Power consumption |
10 A |
Bath
|
Bath tank
|
Tritan
|
Usable bath opening (W x L / D) |
5.9 x 5.9 / 5.9 in.
|
Cooling
|
Cooling coil
|
accessory
|
Other
Classification
according to DIN12876-1
|
Classification I (NFL)
|
IP Code
according to IEC 60529
|
IP 21
|
|
Pump type
|
Immersion Pump |
Electronics
|
Temperature control
|
PID1
|
|
Absolute temperature calibration
|
1 Point Calibration
|
|
Temperature display
|
LED
|
|
Temperature setting
|
Keypad
|
Available voltage versions
| 9011305.22 |
100-115V 50/60Hz (Nema N5-15 Plug) |
| 9011305.33.chn |
230V 50/60Hz (CN Plug) |
| 9011305.33 |
230V 50/60Hz (Schuko Plug - CEE 7/4 Plug Type F) |
| 9011305.04 |
230V 50/60Hz (UK Plug Type BS1363A) |
| 9011305.05 |
230V 50/60Hz (CH Plug Type T12 / 10A) |
| 9011305.13 |
230V 60Hz (Schuko Plug - CEE 7/4 Plug Type F) |
Accessory for CORIO C-BT5
Downloads for CORIO C-BT5
We would also be happy to send you our printed catalogs and brochures by post.
Request brochure