MAGIO MX-1800F Refrigerated / heating circulator

Our most powerful laboratory circulators with the highest cooling and heating capacity

As with all circulators from the MAGIO range, the refrigerated circulators stand out thanks to their premium quality, high performance and intuitive operation. These devices provide extra powerful pressure and suction pumps and have an incredibly high heating output of 3 kW, enabling even more dynamic temperature control for external applications.

With a working temperature range of -50 ... 200 °C, the Refrigerated / heating circulator MAGIO MX-1800F delivers an outstanding cooling capacity of 1.87 kW at 20 °C despite its compact design.

This cooling machine works with natural, environmentally-friendly refrigerant and was developed with a focus on energy efficiency. This means significant savings on the operating costs for numerous applications, which also means rapid amortization of the procurement cost. At the same time, the lower energy consumption positively contributes to climate protection.

High resolution TFT touch display

The modern TFT touch display gives you all the important information at a glance. Three large, predefined main screens clearly display data and graphics with various application priorities. Menu navigation is self-explanatory, arranged by relevance to daily operations and easy to operate with the touch of a finger. The in-built help function provides detailed support in case of additional questions.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
MX-1800F
Order number including voltage version 9033751.N1.04
Working temperature range -50 ... 200 °C
Temperature stability ±0.01 °C
Heating capacity 1.9 kW
Pump capacity flow rate 16 ... 31 l/min
Pump capacity pressure 0.24 ... 0.92 bar
Usable bath opening
(W x L / D)
18 x 13 / 20 cm
Filling volume 6.5 ... 11 l
Total dimensions
(W × L × H)
40 x 50 x 89 cm
Arrange callback

Product Features

  • analog interfaces (accessory)
  • Ideal for demanding external applications
  • Continuously adjustable, extremely powerful pressure / suction pump
  • Parts being in contact with the medium made of stainless steel
  • Connections for solenoid valve
  • NRTL-certified for the US and Canada

Technical data for MAGIO MX-1800F

Dimensions and volumes
Total dimensions
(W × L × H)
40 x 50 x 89 cm
Filling volume 6.5 ... 11 l
Weight 61 kg
Pump connections M16x1 male
Temperature values
Working temperature range -50 ... 200 °C
Temperature stability ±0.01 °C
Setting the resolution of the temperature display 0.01 °C
Temperature display resolution 0.01 °C
Ambient temperature +5 ... +40 °C

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Heating capacity 1.9 kW
Cooling capacity
Cooling capacity 1 Medium: Ethanol
°C 20 0 -20 -30 -40
kW 1 1.87 1.57 0.77 0.47 0.3
Cooling capacity 2 Medium: Ethanol
°C 20 0 -20 -30 -40
kW 1 1.8 1.5 0.7 0.4 0.23
Refrigerant R1270
Global Warming Potential 2
Filling weight 99 g
Carbon dioxide equivalent 0.000198 t

1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.
Cooling capacity 1 = capacity at minimum pump level, cooling capacity 2 = capacity at maximum pump level

Pump capacity flow rate 16 ... 31 l/min
Pump capacity pressure 0.24 ... 0.92 bar
Maximum suction -0.03 ... -0.4 bar
Viscosity max. 70 cSt
Power consumption 13 A
Bath
Bath tank Stainless steel
Bath cover integrated
Usable bath opening
(W x L / D)
18 x 13 / 20 cm
Cooling
Cooling of compressor 1-stage Air
Other
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 20
Pump function Pressure Suction Pump
Pump type Immersion Pump
User Interface Language Chinese / Czech / Dutch / English / Französisch / German / Italian / Japanese / Korean / Polish / Portuguese / Russian / Spanisch / Turkish
Electronics
Interfaces Ethernet / Modbus TCP/IP / RS232 / RS485 / Stakei / USB
External pt100 sensor connection integrated
Integrated programmer 8x60 steps
Temperature control ICC
Absolute temperature calibration 10 Point Calibration
Temperature display 7" TFT Touchscreen
Temperature setting Touchscreen
Electronic Timer
h:min
00:00 ... 99:59
Available voltage versions
9033751.N1.33.chn 200-230V 50/60Hz (CN Plug) (R1270)
9033751.N1.33 200-230V 50/60Hz (Multiple Plugs (EU / US)) (R1270)
9033751.N1.04 200-230V 50/60Hz (UK Plug Type BS1363A) (R1270)
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)
Contact expert

Pump capacity

Medium: Water

Cool-down time

Heat-up time

Accessory for MAGIO MX-1800F

Downloads for MAGIO MX-1800F

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

MAGIO MX-1800F Benefits

Intelligent temperature control.

Intelligent cascade control - automatic and self-optimizing adaptation of the PID control parameters with external stability of +/- 0.05 °C.

Many interfaces.

Straight-forward remote control, data management, and integration into process structures. USB, Ethernet, RS232, SD card, and alarm off are permanently integrated. Further interfaces available as accessories.

Touch display. Perfect operation.

With the touch display, the user always has an overview of all values and functions. The intuitive and multilingual menu structure enables perfect control.

Maximum safety.

Classification III according to DIN12876-1 enables safe operation, even with flammable fluids. Automatic switch-off in the event of high temperature or low liquid level.

Show all 20 benefits