FK31-SL Calibration bath
with integrated cooling machine for working temperatures up to -30 °C
The calibration baths in this category feature an integrated refrigeration unit and are suitable for calibration applications to -30 °C. The bath cover with openings and Viton® sleeves is already included in delivery for all models.
Order No. | 9352628.04 | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -30 ... +200 °C | |||||||||||||||||
Temperature stability | ±0.005 °C | |||||||||||||||||
Heating capacity | 2 kW | |||||||||||||||||
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
||||||||||||||||||
Pump capacity flow pressure | 22 ... 26 l/min | |||||||||||||||||
Circulation capacity pressure | 0.4 ... 0.7 bar | |||||||||||||||||
Usable bath opening (W x L / D) |
12 x 0 / 31 cm | |||||||||||||||||
Filling volume | 24 l | |||||||||||||||||
Dimensions
(W × L × H) |
32 x 45 x 91 cm |
Product Features
- LCD DIALOG DISPLAY backlit for convenient interactive operation
- ICC (Intelligent Cascade Control), self-optimizing temperature control
- TCF Temperature Control Features to optimize the control behavior
- Integrated programmer for 6 x 60 program steps
- Highest temperature stability to ±0.005 °C (±0.02 °C at +200 °C)
- Temperature uniformity better than ±0.01 °C
- Optional Pt100 sensor for reference temperature measurements
- Temperature chamber with overflow at maximum liquid level
Technical data for FK31-SL
Dimensions (W × L × H) |
32 x 45 x 91 cm |
---|---|
Filling volume | 24 l |
Usable immersion depth | 31 cm |
Weight | 51 kg |
Working temperature range | -30 ... +200 °C |
---|---|
Temperature stability | ±0.005 °C |
Temperature display resolution | 0.01 °C |
Ambient temperature | +5 ... +40 °C |
Heating capacity | 2 kW | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
||||||||||||||||||
Pump capacity flow pressure | 22 ... 26 l/min | |||||||||||||||||
Circulation capacity pressure | 0.4 ... 0.7 bar | |||||||||||||||||
Maximum suction | 0.2 ... 0.4 bar | |||||||||||||||||
Viscosity max. | 70 cSt | |||||||||||||||||
Power consumption | 5 A |
Bath tank | Stainless steel |
---|---|
Bath cover | integrated |
Usable bath opening (W x L / D) |
12 x 0 / 31 cm |
Cooling coil | not available |
---|---|
Cooling of compressor | 1-stage Air |
Classification according to DIN12876-1 |
Classification III (FL) |
---|---|
IP Code according to IEC 60529 |
IP 21 |
Pump type | Immersion Pump |
Interfaces | Profibus optional |
---|---|
External pt100 sensor connection | integrated |
Integrated programmer | 6x60 steps |
Temperature control | ICC |
Absolute temperature calibration | 3 Point Calibration |
Temperature display | VFD |
Temperature setting | Keypad |
9352628.02 | 115V/60Hz (Nema N5-15 Plug) (R134a) |
---|---|
9352628.03 | 230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F) (R134a) |
9352628.04 | 230V/50Hz (UK Plug Type BS1363A) (R134a) |
Including bath cover with seven openings |
Accessory for FK31-SL
Downloads for FK31-SL
We would also be happy to send you our printed catalogs and brochures by post.
Request brochureFK31-SL Benefits
For flammable bath fluid
Classification III (FL) according to DIN 12876-1
ATC3. Calibration.
‘Absolute Temperature Calibration’ for compensating a physically caused temperature difference, 3-point calibration.
Process. Under control.
Full regulation of the dynamics control, access to all important control parameters for individual process optimization.
100 % Cooling capacity
‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures